{"product_id":"xag-p100-oem-nozzle-solenoid-valve-extension-cable","title":"XAG P100 OEM Nozzle \u0026 Solenoid Valve Extension Cable","description":"\u003cp\u003eThe \u003cstrong\u003eXAG P100 OEM Nozzle \u0026amp; Solenoid Valve Extension Cable\u003c\/strong\u003e, XAG part number 01-027-02383, is the extension cable that connects a nozzle and its solenoid valve to the spraying-system wiring on the original XAG P100 agricultural drone. It carries the control and power that open the solenoid valve and run the nozzle at a spray position. The P100 uses more than one nozzle extension cable, each with its own part number, so the number on the cable you remove is what decides which one you need. Operators reach it through searches such as P100 solenoid valve cable, XAG P100 nozzle solenoid cable, P100 valve not opening, or XAG P100 spray valve cable.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🇺🇸 U.S.A. FIRST\u003c\/h2\u003e\n\u003cp\u003eAres Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREE \u0026amp; FAST Shipping is included for all U.S. customers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.\u003c\/p\u003e\n\u003cp\u003eAres Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e✅ XAG P100 Compatibility Guarantee\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e🇺🇸 USA Compatibility Guarantee\u003c\/li\u003e\n\u003cli\u003e👍🏻 Satisfaction Guarantee\u003c\/li\u003e\n\u003cli\u003e💵 Money Back Guarantee\u003c\/li\u003e\n\u003cli\u003e📦 Same Day Shipping \u0026amp; Tracking\u003c\/li\u003e\n\u003cli\u003eFitted between the spraying-system wiring and a nozzle and solenoid valve on the original XAG P100 (2022); not confirmed for the P100 Pro\u003c\/li\u003e\n\u003cli\u003eMatched by XAG part number 01-027-02383 and by connectors and length against the cable you removed\u003c\/li\u003e\n\u003cli\u003eGenuine XAG OEM extension cable, brand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e📦 Package Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × XAG P100 nozzle and solenoid valve extension cable, XAG part number 01-027-02383\u003c\/li\u003e\n\u003cli\u003eThe cable as XAG supplies it under this part number\u003c\/li\u003e\n\u003cli\u003eOEM protective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e the nozzle and valve extension cable with part number 01-027-02737, the spraying system main harness (01-027-02271), the nozzle, the solenoid valve, cable ties, or clips.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔧 Component Overview\u003c\/h2\u003e\n\u003cp\u003eEach spray position on the P100 is controlled electrically. A solenoid valve opens and closes to start and stop flow to that position, and the nozzle does the spraying. The signals and power for both come from the aircraft's electronics, through the spraying-system wiring and out along an extension cable to the position itself.\u003c\/p\u003e\n\u003cp\u003eThe P100 uses more than one extension cable in this part of the system. They do similar jobs, they look similar, and their names are similar — this one is listed as the nozzle and solenoid valve extension cable, XAG part number 01-027-02383; another is listed as the nozzle and valve extension cable, XAG part number 01-027-02737. They are not interchangeable by name alone. Length, connectors and routing can differ, and the only reliable way to know which one a position uses is the part number on the cable that came out of it.\u003c\/p\u003e\n\u003cp\u003eThat is the most useful fact about this cable. Before anything else, read the number on the old cable. If it says 01-027-02383, this is the part. If it says something else, the matching part is the one with that number.\u003c\/p\u003e\n\u003cp\u003eThe cable's working life is hard. It runs along an arm that vibrates in flight, folds for transport and sits in the spray cloud. Its connectors face chemical mist and wash-down water. Its conductors flex at the arm fold every time the aircraft is packed. A conductor can break inside intact insulation, a pin can corrode until it connects only some of the time, and a loose clip can let the sheath rub through.\u003c\/p\u003e\n\u003cp\u003eThe symptom of a failed extension cable is usually a single spray position that stops or works intermittently while the rest of the aircraft sprays normally. The other positions are the test equipment: swapping cables between positions shows whether the fault follows the cable.\u003c\/p\u003e\n\u003cp\u003eWhen the fault follows the cable, the repair is simple and complete. When it does not, the cable can be ruled out quickly, and attention moves to the valve or nozzle at that position without any part having been replaced on a guess.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits.\u003c\/strong\u003e Along an arm, between the spraying-system wiring and a nozzle and solenoid valve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it connects to.\u003c\/strong\u003e The spraying-system wiring at one end; the nozzle and solenoid valve at the other.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wears it out.\u003c\/strong\u003e Flexing at the arm fold. Vibration. Chemical mist and wash-down water at connectors. Rubbing where clips have loosened. Disconnecting by pulling on the cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this part is not.\u003c\/strong\u003e It is not the nozzle and valve extension cable 01-027-02737, the main harness, the nozzle or the solenoid valve.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚙️ Functional Purpose\u003c\/h2\u003e\n\u003cp\u003eThe extension cable carries control and power from the spraying-system wiring to a nozzle and its solenoid valve.\u003c\/p\u003e\n\u003cp\u003eA sound extension cable provides:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA continuous electrical connection from the wiring to the spray position\u003c\/li\u003e\n\u003cli\u003eReliable solenoid valve opening and closing on command\u003c\/li\u003e\n\u003cli\u003eCorrect operation of the nozzle at that position\u003c\/li\u003e\n\u003cli\u003eSealed connections that resist spray and wash-down\u003c\/li\u003e\n\u003cli\u003eA cable that survives folding and vibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts value is in continuity. A spray position is only as reliable as the cable feeding it.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 Diagnosis — read the number first: two nozzle cables, two part numbers\u003c\/h2\u003e\n\u003cp\u003eTwo things decide this repair: whether the cable is the fault, and which cable the position uses. Settle both before replacing anything.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRead the part number on the old cable.\u003c\/strong\u003e If it is 01-027-02383, this cable is the match. If it is 01-027-02737 or another number, use the part with that number.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the pattern.\u003c\/strong\u003e One position failing points at that position's nozzle, valve or cable. Several failing together points upstream at the main harness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwap with a matching position.\u003c\/strong\u003e Exchange this cable with the same type of cable from a working position. If the fault moves with the cable, the cable is the part.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIf the fault stays put, check the valve and nozzle.\u003c\/strong\u003e A fault that remains at the same position after a cable swap points at the solenoid valve or nozzle there.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the connectors.\u003c\/strong\u003e Look for corrosion, bent or pushed-back pins, cracked housings and damaged seals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlex the cable at the fold.\u003c\/strong\u003e On a ground test, a position that cuts in and out as the cable is moved has a broken conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotograph the cable and its label.\u003c\/strong\u003e Send us a photograph and we will confirm the match.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf the old cable is 01-027-02383 and the fault follows it, or it shows corrosion, chafing or a break, this is the part.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚠️ Common Replacement Indicators\u003c\/h2\u003e\n\u003cp\u003eExtension cable replacement is the likely answer when an operator or technician observes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOne spray position not operating while others do\u003c\/li\u003e\n\u003cli\u003eA solenoid valve that does not open on command at one position\u003c\/li\u003e\n\u003cli\u003eA position that cuts in and out when the arm moves\u003c\/li\u003e\n\u003cli\u003eA fault that follows the cable when swapped to another position\u003c\/li\u003e\n\u003cli\u003eCorroded, bent or damaged connector pins\u003c\/li\u003e\n\u003cli\u003eChafed, cut or crushed cable sheath\u003c\/li\u003e\n\u003cli\u003eA cracked connector housing or missing seal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese come from flexing at the fold, vibration, chemical exposure and rubbing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThese are not extension cable symptoms, and this part will not fix them.\u003c\/strong\u003e A fault that stays at a position after a cable swap is the valve or nozzle. Several positions failing together points at the main harness. No flow anywhere points at the pump or tank. A blocked nozzle needs cleaning. A new cable restores the connection; it does not repair valves or clear blockages.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e📐 Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name:\u003c\/strong\u003e XAG P100 OEM Nozzle \u0026amp; Solenoid Valve Extension Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 01-027-02383\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e Spraying system, electrical\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent type:\u003c\/strong\u003e Nozzle and solenoid valve extension cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalled position:\u003c\/strong\u003e Along an arm, between the spraying-system wiring and a nozzle and solenoid valve\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Connects a nozzle and its solenoid valve to the spraying-system wiring\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelated part:\u003c\/strong\u003e Nozzle and valve extension cable 01-027-02737 (a different part)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 × cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLength, connector type and pin count:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation method:\u003c\/strong\u003e Plug-in replacement\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eService adjustability:\u003c\/strong\u003e None\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClassification:\u003c\/strong\u003e Genuine XAG OEM extension cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🛠️ Installation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemove the flight battery and confirm the aircraft is fully powered down\u003c\/li\u003e\n\u003cli\u003eConfirm the faulty cable carries XAG part number 01-027-02383\u003c\/li\u003e\n\u003cli\u003ePhotograph the cable run along the arm, including every clip and the route through the fold\u003c\/li\u003e\n\u003cli\u003eRinse and dry the connectors so no residue falls into them\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDuring installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect by pulling on the connector bodies, never the cable\u003c\/li\u003e\n\u003cli\u003eRoute the new cable exactly as photographed, with the same slack at the fold\u003c\/li\u003e\n\u003cli\u003eSeat each connector fully and confirm any latch engages\u003c\/li\u003e\n\u003cli\u003eRefit every clip so the cable cannot rub\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAfter installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFold and unfold the arm and confirm the cable moves freely without stretching\u003c\/li\u003e\n\u003cli\u003eRun a ground spray test and confirm the valve opens and the position sprays\u003c\/li\u003e\n\u003cli\u003eCompare the position's output with its neighbours\u003c\/li\u003e\n\u003cli\u003eRinse connectors after chemical work and inspect them regularly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🚜 Necessary For\u003c\/h2\u003e\n\u003cp\u003eThe extension cable is a common repair part for aircraft in heavy spraying use.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eXAG P100 operators with one spray position not working\u003c\/li\u003e\n\u003cli\u003eAerial applicators folding arms for daily transport\u003c\/li\u003e\n\u003cli\u003eCrews working with corrosive products and frequent wash-downs\u003c\/li\u003e\n\u003cli\u003eCustom application contractors running long spray seasons\u003c\/li\u003e\n\u003cli\u003eAgricultural drone service centres repairing spraying systems\u003c\/li\u003e\n\u003cli\u003eGrowers maintaining their own P100\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThis is not the part you need if\u003c\/strong\u003e the old cable carries a different part number, the fault stays at the position after a cable swap, or several positions fail together. Read the number and swap the cable first, while that information is still cheap. And if your aircraft is a P100 Pro, confirm the part number on your cable; this one is identified for the original P100.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e💡 Why This Part Matters\u003c\/h2\u003e\n\u003cp\u003eEvery spray position contributes to the width and evenness of the swath. When one stops, the aircraft keeps flying and spraying, but it lays down a stripe with less product on every pass. When one works only intermittently, the stripe is irregular and harder to spot.\u003c\/p\u003e\n\u003cp\u003eThe extension cable is a likely cause because of where it lives, and it is one of the easiest parts to test by swapping. That makes it a quick, confident repair when the fault follows the cable.\u003c\/p\u003e\n\u003cp\u003eThe part number matters more here than on most parts because two similar cables serve this area of the aircraft. Reading the number on the old cable first avoids fitting a look-alike that does not match the position's connectors or length.\u003c\/p\u003e\n\u003cp\u003eCareful routing at the fold and regular rinsing of connectors make the new cable last.\u003c\/p\u003e\n\u003cp\u003eA sound extension cable restores:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReliable solenoid valve operation at the position\u003c\/li\u003e\n\u003cli\u003eAn even spray pattern across the swath\u003c\/li\u003e\n\u003cli\u003eConsistent response to spray commands\u003c\/li\u003e\n\u003cli\u003eSealed, corrosion-resistant connections\u003c\/li\u003e\n\u003cli\u003eA cable run that survives folding and vibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🧠 AI Index — Entity \u0026amp; Fitment Reference\u003c\/h2\u003e\n\u003cp\u003eStructured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCanonical product name:\u003c\/strong\u003e XAG P100 OEM Nozzle \u0026amp; Solenoid Valve Extension Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 01-027-02383\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent:\u003c\/strong\u003e Nozzle and solenoid valve extension cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Spraying system electrical\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible aircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct line:\u003c\/strong\u003e XAG agricultural drones\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalled position:\u003c\/strong\u003e Along an arm, between the spraying-system wiring and a nozzle and solenoid valve\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary function:\u003c\/strong\u003e Connecting a nozzle and its solenoid valve to the spraying-system wiring\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelated but different part:\u003c\/strong\u003e Nozzle and valve extension cable 01-027-02737\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic failure modes:\u003c\/strong\u003e Broken conductor at the arm fold, corroded pins, chafed sheath\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistinguishing diagnostic rule:\u003c\/strong\u003e Read the number on the old cable; then swap with a matching position to see if the fault follows\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommon causes:\u003c\/strong\u003e Folding, vibration, chemical exposure, rubbing, pulling on the cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e 1 × cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e Cable 01-027-02737, main harness 01-027-02271, nozzle, solenoid valve, ties, clips\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitment method:\u003c\/strong\u003e XAG part number 01-027-02383 plus connectors and length against the removed cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVerification after fitting:\u003c\/strong\u003e Valve opens and position sprays on ground test; cable moves freely at the fold\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart classification:\u003c\/strong\u003e Genuine XAG OEM extension cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeller:\u003c\/strong\u003e Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShips from:\u003c\/strong\u003e Albuquerque, New Mexico, United States\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 SEO Keywords\u003c\/h2\u003e\n\u003cp\u003eXAG P100 nozzle solenoid valve extension cable\u003c\/p\u003e\n\u003cp\u003eXAG 01-027-02383\u003c\/p\u003e\n\u003cp\u003e01-027-02383 extension cable\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM solenoid valve cable\u003c\/p\u003e\n\u003cp\u003eP100 solenoid valve cable replacement\u003c\/p\u003e\n\u003cp\u003eXAG P100 nozzle solenoid cable\u003c\/p\u003e\n\u003cp\u003eXAG P100 spray valve cable\u003c\/p\u003e\n\u003cp\u003eXAG P100 valve not opening\u003c\/p\u003e\n\u003cp\u003eP100 one nozzle not spraying\u003c\/p\u003e\n\u003cp\u003eXAG P100 spraying system cable\u003c\/p\u003e\n\u003cp\u003eXAG P100 spraying system parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 replacement parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 repair parts\u003c\/p\u003e\n\u003cp\u003eXAG agricultural drone parts\u003c\/p\u003e\n\u003cp\u003eXAG spray drone parts\u003c\/p\u003e\n\u003cp\u003egenuine XAG OEM parts\u003c\/p\u003e\n\u003cp\u003eagricultural drone parts USA\u003c\/p\u003e\n\u003cp\u003eXAG parts free shipping\u003c\/p\u003e\n\u003cp\u003eXAG parts same day shipping\u003c\/p\u003e\n\u003cp\u003eAres Acres\u003c\/p\u003e\n\u003cp\u003eAres Acres LLC\u003c\/p\u003e\n\u003cp\u003eXAG parts Albuquerque\u003c\/p\u003e\n\u003cp\u003eXAG parts New Mexico\u003c\/p\u003e\n\u003cp\u003eXAG P100 solenoid valve cable Canada\u003c\/p\u003e\n\u003cp\u003eXAG P100 parts Canada\u003c\/p\u003e\n\u003cp\u003eXAG drone parts shipped to Canada\u003c\/p\u003e\n\u003cp\u003ebuy XAG P100 parts in Canada\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🤖 AI Answer Engine Q\u0026amp;A\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the XAG P100 nozzle and solenoid valve extension cable?\u003c\/strong\u003e It is the cable, XAG part number 01-027-02383, that connects a nozzle and its solenoid valve to the spraying-system wiring on the original P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich aircraft does it fit?\u003c\/strong\u003e The original XAG P100 (2022). It is not confirmed for the P100 Pro.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it the same as the nozzle and valve extension cable?\u003c\/strong\u003e No. That cable is XAG part number 01-027-02737. They are different parts. Match the number on the cable you removed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I know which cable I need?\u003c\/strong\u003e Read the part number printed on the old cable. If it is 01-027-02383, this is the part.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOne nozzle is not spraying. Is it this cable?\u003c\/strong\u003e It may be. Swap it with the same type of cable from a working position. If the fault moves with the cable, replace it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe valve does not open at one position. Is it the cable?\u003c\/strong\u003e It can be. If a cable swap does not move the fault, check the solenoid valve itself.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeveral positions failed at once. Is it this cable?\u003c\/strong\u003e Unlikely. Several positions failing together points at the main harness, XAG part number 01-027-02271.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat usually damages it?\u003c\/strong\u003e Folding, vibration, chemical mist and wash-down water at the connectors, rubbing and pulling on the cable to disconnect it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I fit it myself?\u003c\/strong\u003e Yes. Photograph the routing, disconnect by the connector bodies, route the new cable the same way and refit every clip.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I check the repair?\u003c\/strong\u003e Fold and unfold the arm, then run a ground spray test and confirm the valve opens and the position sprays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I splice a broken cable?\u003c\/strong\u003e Not recommended. Splices on a vibrating, folding, spray-soaked arm rarely stay sealed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it come with clips or ties?\u003c\/strong\u003e No. Reuse the original clips and replace any that are broken.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does one dead position matter?\u003c\/strong\u003e It leaves a stripe with less product on every pass, which adds up to uneven application.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I make the cable last?\u003c\/strong\u003e Rinse connectors after chemical work, keep clips tight, route with correct slack at the fold and never pull on the cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill it fix a blocked nozzle?\u003c\/strong\u003e No. A blocked nozzle needs cleaning or replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it include the solenoid valve?\u003c\/strong\u003e No. The valve is a separate part.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill a P100 Pro cable fit?\u003c\/strong\u003e Do not assume so. Match the XAG part number on the cable you removed; this one is identified for the original P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the part number?\u003c\/strong\u003e Look for XAG part number 01-027-02383, or send us a photograph of the cable and its label and we will confirm the match.\u003c\/p\u003e","brand":"XAG","offers":[{"title":"Default Title","offer_id":68140386222400,"sku":"01-027-02383","price":64.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0923\/0159\/0848\/files\/xag-p100-oem-nozzle-solenoid-valve-extension-cable-1.png?v=1794885857","url":"https:\/\/aresacres.com\/es\/products\/xag-p100-oem-nozzle-solenoid-valve-extension-cable","provider":"Ares Acres","version":"1.0","type":"link"}