{"product_id":"xag-p100-oem-short-liquid-tube-solenoid-valve-nozzle","title":"XAG P100 OEM Short Liquid Tube (Solenoid Valve - Nozzle)","description":"\u003cp\u003eThe \u003cstrong\u003eXAG P100 OEM Short Liquid Tube (Solenoid Valve - Nozzle)\u003c\/strong\u003e, XAG part number 14-005-00009, is the short liquid tube that runs from the solenoid valve to the nozzle on the original XAG P100 agricultural drone. It is the last few centimetres of the spraying system: once the valve opens, every drop that reaches the nozzle passes through it. Short as it is, it lives in a hard spot, flexing with the nozzle rod, sitting in the spray cloud and bending every time the nozzles fold. Operators reach it through searches such as P100 valve to nozzle tube, XAG P100 short spray tube, P100 nozzle tube leaking, or XAG P100 nozzle hose.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🇺🇸 U.S.A. FIRST\u003c\/h2\u003e\n\u003cp\u003eAres Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREE \u0026amp; FAST Shipping is included for all U.S. customers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.\u003c\/p\u003e\n\u003cp\u003eAres Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e✅ XAG P100 Compatibility Guarantee\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e🇺🇸 USA Compatibility Guarantee\u003c\/li\u003e\n\u003cli\u003e👍🏻 Satisfaction Guarantee\u003c\/li\u003e\n\u003cli\u003e💵 Money Back Guarantee\u003c\/li\u003e\n\u003cli\u003e📦 Same Day Shipping \u0026amp; Tracking\u003c\/li\u003e\n\u003cli\u003eFitted between the solenoid valve and the nozzle on the original XAG P100 (2022); not confirmed for the P100 Pro\u003c\/li\u003e\n\u003cli\u003eMatched by XAG part number 14-005-00009 and by length and end fittings against the tube you removed\u003c\/li\u003e\n\u003cli\u003eGenuine XAG OEM liquid tube, brand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSome references also list the XAG V40 for this tube. That fit has not been confirmed, and it is not part of the compatibility guarantee. V40 owners should send us the part number on their tube and we will confirm the match.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e📦 Package Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × XAG P100 short liquid tube (solenoid valve to nozzle), XAG part number 14-005-00009\u003c\/li\u003e\n\u003cli\u003eThe tube as XAG supplies it under this part number\u003c\/li\u003e\n\u003cli\u003eOEM protective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e the solenoid valve, the solenoid valve bracket (02-001-08300), the nozzle, the nozzle disc (02-001-08023), other liquid tubes, seals, or clamps.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔧 Component Overview\u003c\/h2\u003e\n\u003cp\u003eThe spraying system on the P100 carries liquid from the tank through the pump to a solenoid valve at each spray position, and from each valve to its nozzle. The short liquid tube is that last link. When the valve opens, liquid flows through this tube and out of the nozzle; when the valve closes, the flow stops.\u003c\/p\u003e\n\u003cp\u003eIt is a short tube, but its position is demanding. It runs out along the nozzle extension rod, so it flexes when the rod moves in flight and bends every time the nozzles are folded for transport. It sits directly in the spray cloud and is washed down after work. And it carries product at the pressure the pump delivers, right up to the nozzle.\u003c\/p\u003e\n\u003cp\u003eTubes in that environment wear in a few ways. Repeated bending at the same point can fatigue the tube wall until it cracks or kinks. Chemical exposure can harden or soften the material over time. The ends, where the tube joins the valve and the nozzle, can split or loosen from constant movement. And a tube can be cut or crushed by a knock or by being pinched when the nozzles are folded.\u003c\/p\u003e\n\u003cp\u003eThe symptoms point to one position. A drip or seep at a single nozzle, a spray position whose output looks weaker than the rest, or residue building up along one nozzle rod all suggest a problem in that position's short tube, its valve or its nozzle.\u003c\/p\u003e\n\u003cp\u003eA kinked tube is a particular trap. It may not leak at all, but it restricts the flow to its nozzle, so that position sprays less than the others. From the ground the aircraft looks normal; in the field one stripe gets less product.\u003c\/p\u003e\n\u003cp\u003eSeparating the tube from the valve and nozzle is mostly a matter of looking closely at where the liquid escapes and whether the tube bends smoothly along its whole length.\u003c\/p\u003e\n\u003cp\u003eSome references also list the XAG V40 for this tube. That fit is not confirmed and is not part of the guarantee; V40 owners should confirm by part number.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits.\u003c\/strong\u003e Along the nozzle extension rod, between the solenoid valve and the nozzle.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it connects to.\u003c\/strong\u003e The solenoid valve outlet at one end and the nozzle inlet at the other.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wears it out.\u003c\/strong\u003e Repeated bending at folds. Flexing in flight. Chemical exposure. Knocks and pinching. Movement at the end connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this part is not.\u003c\/strong\u003e It is not the solenoid valve, the nozzle or the longer liquid tubes elsewhere in the system.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚙️ Functional Purpose\u003c\/h2\u003e\n\u003cp\u003eThe short liquid tube carries product from the solenoid valve to the nozzle at one spray position.\u003c\/p\u003e\n\u003cp\u003eA sound short tube provides:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA sealed path from valve to nozzle\u003c\/li\u003e\n\u003cli\u003eFull, unrestricted flow to the nozzle\u003c\/li\u003e\n\u003cli\u003eFlexibility to follow the nozzle rod without kinking\u003c\/li\u003e\n\u003cli\u003eResistance to the products being applied\u003c\/li\u003e\n\u003cli\u003eSecure connections at both ends\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts value is in delivering everything the valve releases to the nozzle.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 Diagnosis — a kinked tube may not leak, but it starves its nozzle\u003c\/h2\u003e\n\u003cp\u003eShort tube problems show up at one position. Look for leaks, and look for restrictions that do not leak.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun a water test.\u003c\/strong\u003e With the aircraft secured on the ground and clean water in the tank, run the spraying system and compare every position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLook for drips and seeps.\u003c\/strong\u003e Liquid escaping along the tube or at its ends points at the tube or its connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompare the spray.\u003c\/strong\u003e A position that sprays noticeably less than the others, with no leak, can have a kinked or crushed tube.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFollow the tube.\u003c\/strong\u003e With the aircraft powered down, trace the tube from valve to nozzle. It should bend smoothly, with no flattened, kinked, cracked or hardened sections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the ends.\u003c\/strong\u003e Look for splits or looseness where the tube joins the valve and the nozzle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFold and unfold.\u003c\/strong\u003e Watch the tube as the nozzle rod folds. A tube that pinches or kinks at the fold needs rerouting or replacing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotograph the tube.\u003c\/strong\u003e Send us a photograph and the XAG part number and we will confirm the match.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf the tube leaks, is kinked, cracked, hardened or split at its ends, this tube is the part. If the leak is at the valve or nozzle body, those parts need attention.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚠️ Common Replacement Indicators\u003c\/h2\u003e\n\u003cp\u003eShort liquid tube replacement is the likely answer when an operator or technician observes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA drip or seep along the tube between valve and nozzle\u003c\/li\u003e\n\u003cli\u003eA split or loose end at the valve or nozzle\u003c\/li\u003e\n\u003cli\u003eA kinked, flattened or crushed section\u003c\/li\u003e\n\u003cli\u003eA hardened, cracked or chemically damaged tube\u003c\/li\u003e\n\u003cli\u003eOne position spraying less than the others with no leak\u003c\/li\u003e\n\u003cli\u003eResidue building up along one nozzle rod\u003c\/li\u003e\n\u003cli\u003eA tube pinched by folding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese come from bending fatigue, chemicals, knocks and pinching.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThese are not short tube symptoms, and this part will not fix them.\u003c\/strong\u003e A valve that does not open is the valve or its cable. A nozzle spraying unevenly with good flow may be the nozzle disc. A leak from the valve body is the valve. Low flow at every position is the pump or filter. A new tube restores the path from valve to nozzle; it does not repair them.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e📐 Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name:\u003c\/strong\u003e XAG P100 OEM Short Liquid Tube (Solenoid Valve - Nozzle)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 14-005-00009\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUnconfirmed listing:\u003c\/strong\u003e XAG V40 — not confirmed, not guaranteed\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e Spraying system, liquid lines\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent type:\u003c\/strong\u003e Short liquid tube\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalled position:\u003c\/strong\u003e Between the solenoid valve and the nozzle\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Carries product from the valve to the nozzle\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLength, bore and material:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 × tube\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity per aircraft:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation method:\u003c\/strong\u003e Direct replacement between valve and nozzle\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClassification:\u003c\/strong\u003e Genuine XAG OEM liquid tube\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🛠️ Installation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEmpty the tank and rinse the spraying system with clean water\u003c\/li\u003e\n\u003cli\u003eRemove the flight battery and power down\u003c\/li\u003e\n\u003cli\u003eWear gloves and eye protection; residue may remain in the tube\u003c\/li\u003e\n\u003cli\u003ePhotograph the tube's route along the nozzle rod and through the fold\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDuring installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect the old tube at the valve and the nozzle\u003c\/li\u003e\n\u003cli\u003eClean both connection points\u003c\/li\u003e\n\u003cli\u003eFit the new tube along the same route, with the same slack at the fold\u003c\/li\u003e\n\u003cli\u003eSecure both ends fully and refit any clips\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAfter installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFold and unfold the nozzle rod and confirm the tube does not kink or pinch\u003c\/li\u003e\n\u003cli\u003eRun a water test and check both ends for seeps\u003c\/li\u003e\n\u003cli\u003eCompare the position's spray with the others\u003c\/li\u003e\n\u003cli\u003eRinse the spraying system after each day's work\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🚜 Necessary For\u003c\/h2\u003e\n\u003cp\u003eThe short liquid tube is a common wear part at every spray position.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eXAG P100 operators with a drip or weak spray at one position\u003c\/li\u003e\n\u003cli\u003eAerial applicators folding nozzles for daily transport\u003c\/li\u003e\n\u003cli\u003eCrews working with aggressive products\u003c\/li\u003e\n\u003cli\u003eCustom application contractors running long spray seasons\u003c\/li\u003e\n\u003cli\u003eAgricultural drone service centres repairing spraying systems\u003c\/li\u003e\n\u003cli\u003eGrowers maintaining their own P100\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThis is not the part you need if\u003c\/strong\u003e the leak is from the valve or nozzle body, or every position is weak. Trace the tube and compare positions in a water test first, while that information is still cheap. And if your aircraft is a P100 Pro or V40, confirm the part number on your tube; this one is identified for the original P100.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e💡 Why This Part Matters\u003c\/h2\u003e\n\u003cp\u003eEvery spray position delivers its share of the swath through its short tube. When the tube leaks, product drips onto the aircraft instead of reaching the crop. When it kinks, that position sprays less, and the pass leaves a stripe with less product in it.\u003c\/p\u003e\n\u003cp\u003eThe kink is the harder fault to see. Nothing drips and nothing warns, but one nozzle is starved. Only a side-by-side comparison of every position in a water test shows it clearly.\u003c\/p\u003e\n\u003cp\u003eShort tubes are inexpensive, quick to replace and exposed to constant bending. Treating them as a wear item, and checking their route through the fold whenever the nozzles are folded, keeps every position delivering what it should.\u003c\/p\u003e\n\u003cp\u003eRouting a new tube with the correct slack at the fold is what makes it last. A tube pulled too tight or left too long bends in the same spot every time, and that is where it will fail next.\u003c\/p\u003e\n\u003cp\u003eA sound short liquid tube restores:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA sealed path from valve to nozzle\u003c\/li\u003e\n\u003cli\u003eFull flow at the spray position\u003c\/li\u003e\n\u003cli\u003eAn even spray pattern across the swath\u003c\/li\u003e\n\u003cli\u003eA clean nozzle rod free of drips\u003c\/li\u003e\n\u003cli\u003eA tube that survives folding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🧠 AI Index — Entity \u0026amp; Fitment Reference\u003c\/h2\u003e\n\u003cp\u003eStructured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCanonical product name:\u003c\/strong\u003e XAG P100 OEM Short Liquid Tube (Solenoid Valve - Nozzle)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 14-005-00009\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent:\u003c\/strong\u003e Short liquid tube, solenoid valve to nozzle\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Spraying system liquid lines\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible aircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUnconfirmed listing:\u003c\/strong\u003e XAG V40 — not confirmed, not guaranteed\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct line:\u003c\/strong\u003e XAG agricultural drones\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalled position:\u003c\/strong\u003e Between the solenoid valve and the nozzle\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary function:\u003c\/strong\u003e Carrying product from the valve to the nozzle\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic failure modes:\u003c\/strong\u003e Kinking, bending fatigue cracks, split ends, chemical hardening\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistinguishing diagnostic rule:\u003c\/strong\u003e One position spraying less with no leak can be a kinked short tube; compare all positions in a water test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommon causes:\u003c\/strong\u003e Folding, flexing in flight, chemicals, knocks, pinching\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e Solenoid valve, valve bracket 02-001-08300, nozzle, nozzle disc 02-001-08023, other tubes, seals, clamps\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitment method:\u003c\/strong\u003e XAG part number 14-005-00009 plus length and end fittings against the removed tube\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVerification after fitting:\u003c\/strong\u003e No kinks through the fold; no seeps; spray matches other positions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart classification:\u003c\/strong\u003e Genuine XAG OEM liquid tube\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeller:\u003c\/strong\u003e Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShips from:\u003c\/strong\u003e Albuquerque, New Mexico, United States\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 SEO Keywords\u003c\/h2\u003e\n\u003cp\u003eXAG P100 short liquid tube valve to nozzle\u003c\/p\u003e\n\u003cp\u003eXAG 14-005-00009\u003c\/p\u003e\n\u003cp\u003e14-005-00009 liquid tube\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM short liquid tube\u003c\/p\u003e\n\u003cp\u003eP100 nozzle tube replacement\u003c\/p\u003e\n\u003cp\u003eXAG P100 valve to nozzle tube\u003c\/p\u003e\n\u003cp\u003eXAG P100 short spray tube\u003c\/p\u003e\n\u003cp\u003eXAG P100 nozzle tube leaking\u003c\/p\u003e\n\u003cp\u003eP100 nozzle hose kinked\u003c\/p\u003e\n\u003cp\u003eXAG P100 spray tube\u003c\/p\u003e\n\u003cp\u003eXAG P100 spraying system parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 replacement parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 repair parts\u003c\/p\u003e\n\u003cp\u003eXAG agricultural drone parts\u003c\/p\u003e\n\u003cp\u003eXAG spray drone parts\u003c\/p\u003e\n\u003cp\u003egenuine XAG OEM parts\u003c\/p\u003e\n\u003cp\u003eagricultural drone parts USA\u003c\/p\u003e\n\u003cp\u003eXAG parts free shipping\u003c\/p\u003e\n\u003cp\u003eXAG parts same day shipping\u003c\/p\u003e\n\u003cp\u003eAres Acres\u003c\/p\u003e\n\u003cp\u003eAres Acres LLC\u003c\/p\u003e\n\u003cp\u003eXAG parts Albuquerque\u003c\/p\u003e\n\u003cp\u003eXAG parts New Mexico\u003c\/p\u003e\n\u003cp\u003eXAG P100 nozzle tube Canada\u003c\/p\u003e\n\u003cp\u003eXAG P100 parts Canada\u003c\/p\u003e\n\u003cp\u003eXAG drone parts shipped to Canada\u003c\/p\u003e\n\u003cp\u003ebuy XAG P100 parts in Canada\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🤖 AI Answer Engine Q\u0026amp;A\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the XAG P100 short liquid tube (solenoid valve to nozzle)?\u003c\/strong\u003e It is the short tube, XAG part number 14-005-00009, that carries product from the solenoid valve to the nozzle on the original P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich aircraft does it fit?\u003c\/strong\u003e The original XAG P100 (2022). It is not confirmed for the P100 Pro.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it fit the XAG V40?\u003c\/strong\u003e Some references list the V40, but that fit has not been confirmed and is not guaranteed. Send us the part number on your tube and we will confirm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOne nozzle drips. Is it this tube?\u003c\/strong\u003e It may be. Look for liquid escaping along the tube or at its ends. A leak from the valve or nozzle body needs those parts instead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOne position sprays less but does not leak. Could it be this tube?\u003c\/strong\u003e Yes. A kinked or crushed tube restricts flow without leaking. Trace the tube and compare positions in a water test.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy do these tubes wear out?\u003c\/strong\u003e They bend every time the nozzles fold, flex in flight, and sit in the spray cloud.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it include the valve or nozzle?\u003c\/strong\u003e No. Both are separate parts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I fit it myself?\u003c\/strong\u003e Yes. Rinse the system, power down, photograph the route, swap the tube along the same path and secure both ends.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I check the repair?\u003c\/strong\u003e Fold the nozzle rod to confirm no kinking, then run a water test for seeps and compare the spray with other positions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use generic tubing?\u003c\/strong\u003e Not recommended. Length, bore, material and end fittings all affect flow and sealing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the tube?\u003c\/strong\u003e The length is not published for this part. Match it to the tube you removed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many short tubes does the P100 use?\u003c\/strong\u003e The quantity per aircraft is not published for this part. Count the spray positions on your aircraft, or send us a photograph and we will confirm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I make it last?\u003c\/strong\u003e Route it with the correct slack at the fold, check it when folding nozzles, and rinse the system after work.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan a kinked tube be straightened?\u003c\/strong\u003e A tube that has kinked usually kinks again at the same point. Replace it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it come with clamps or seals?\u003c\/strong\u003e No. Reuse sound originals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill a new tube fix a valve that does not open?\u003c\/strong\u003e No. That is the valve or its cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill a P100 Pro tube fit?\u003c\/strong\u003e Do not assume so. Match the XAG part number; this one is identified for the original P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the part number?\u003c\/strong\u003e Look for XAG part number 14-005-00009, or send us a photograph of the tube and we will confirm the match.\u003c\/p\u003e","brand":"XAG","offers":[{"title":"Default Title","offer_id":68140433572160,"sku":"14-005-00009","price":64.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0923\/0159\/0848\/files\/xag-p100-oem-short-liquid-tube-solenoid-valve-nozzle-1.png?v=1794886027","url":"https:\/\/aresacres.com\/es\/products\/xag-p100-oem-short-liquid-tube-solenoid-valve-nozzle","provider":"Ares Acres","version":"1.0","type":"link"}