{"product_id":"dji-talos-t60x-oem-flow-meter-water-outlet-hose","title":"DJI Talos T60X OEM Flow Meter Water Outlet Hose","description":"\u003cp\u003eThe DJI Talos T60X OEM Flow Meter Water Outlet Hose is the short, clear, pre-formed hose that carries liquid away from the flow meter of the Talos T60X spraying system, after the meter has measured it. In the product images it is a single length of translucent white tube with a long, nearly straight leg, a shallow S-curve in the middle and a tight hook that turns the far end upward, holding that shape on its own. It is the connection on the outlet side of the flow meter, and it is the sibling of the Flow Meter Water Inlet Hose on the other side of the same meter. It is identified for the Talos T60X. Send us a photograph of the label on the part you removed and we will match it before it ships. Operators usually come looking for a Talos T60X flow meter outlet hose, meter outlet tube or flow meter hose after finding damp or residue below the meter, a cracked or hardened hose, or a field that came up short on product while the flow reading looked normal.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🇺🇸 U.S.A. FIRST\u003c\/h2\u003e\n\u003cp\u003eAres Acres LLC is a U.S.-based authorized DJI retailer supplying agricultural spray aircraft, replacement components, and field-ready inventory to American commercial operators, service centres, and applicators.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREE \u0026amp; FAST Shipping is included for all U.S. customers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.\u003c\/p\u003e\n\u003cp\u003eAres Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one authorized DJI retailer serving the United States and Canada, all of North America, from Albuquerque, New Mexico.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e✅ DJI Talos T60X Compatibility Guarantee\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e🇺🇸 USA Compatibility Guarantee\u003c\/li\u003e\n\u003cli\u003e👍🏻 Satisfaction Guarantee\u003c\/li\u003e\n\u003cli\u003e💵 Money Back Guarantee\u003c\/li\u003e\n\u003cli\u003e📦 Same Day Shipping \u0026amp; Tracking\u003c\/li\u003e\n\u003cli\u003eIdentified for the Talos T60X\u003c\/li\u003e\n\u003cli\u003eMatched by length, S-curve, hook and ends against the outlet hose you removed\u003c\/li\u003e\n\u003cli\u003eGenuine DJI OEM spraying-system hose, brand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSend us a photograph of the label on the part you removed and we will match it before it ships. A photograph of the old hose laid flat, with the end that met the flow meter marked, settles whether it is the outlet hose or the inlet hose.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e📦 Package Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × DJI Talos T60X OEM Flow Meter Water Outlet Hose, the clear S-bend hose as photographed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOne hose, supplied on its own.\u003c\/strong\u003e It is a single pre-formed length with its S-curve and end hook already in place.\u003c\/p\u003e\n\u003cp\u003eNot included: the Flow Meter Water Inlet Hose, the flow meter, the Flow Meter Module (Incl. Signal Cable), hose clamps, sealing rings, the Spray Hose (2 sets) for the spray boom, and any other spraying-system part.\u003c\/p\u003e\n\u003cp\u003eIf both flow meter hoses need replacing, the inlet hose is a separate part and is ordered alongside this one.\u003c\/p\u003e\n\u003cp\u003eNothing is included because it appears in a photograph. The photograph shows the outlet hose alone.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔧 Component Overview\u003c\/h2\u003e\n\u003cp\u003eThe flow meter sits in the spray line and measures the liquid passing through it. Two short hoses connect it: the inlet hose brings liquid to the meter, and the water outlet hose takes the measured liquid away from the meter and on along the spray line.\u003c\/p\u003e\n\u003cp\u003eOn the Talos T60X the outlet hose is a clear, translucent white tube. The product images show a long, nearly straight leg, a shallow S-curve where the tube steps down, and a tight hook at the far end that turns the end of the hose upward. The hose holds that shape by itself, which tells you the curves are formed in rather than forced in at fitting.\u003c\/p\u003e\n\u003cp\u003eIts position is what makes it different from every other hose on the aircraft. Everything that passes through the outlet hose has already been counted by the flow meter. That is not true of the inlet hose, and it is the reason a fault on this hose behaves differently from a fault on the inlet side.\u003c\/p\u003e\n\u003cp\u003eHow to tell the outlet hose from the inlet hose: both are short, clear and pre-formed, and both end at the flow meter. The outlet hose is the one connected to the meter's outlet port, the side the liquid leaves by. The outlet hose in the product images carries a shallow S-curve along its length as well as the hook at its end; the inlet hose is described as a straight leg with a single tight bend. If you are not sure which port your hose came off, photograph it in place and send it to us.\u003c\/p\u003e\n\u003cp\u003eIt is also not a spray-boom hose. The Spray Hose (2 sets) runs out to the spray boom. The outlet hose is the short formed connection at the meter, and the Flow Meter Module (Incl. Signal Cable) is the meter itself, which is a separate part.\u003c\/p\u003e\n\u003cp\u003eWhat the outlet hose lives with, over a working season:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEvery litre that has passed through the flow meter\u003c\/li\u003e\n\u003cli\u003eMix left standing in the line between jobs, which leaves residue in a clear tube\u003c\/li\u003e\n\u003cli\u003eChemical attack on the tube wall from some mixes over time\u003c\/li\u003e\n\u003cli\u003eVibration from the propulsion system and the spraying system\u003c\/li\u003e\n\u003cli\u003eBeing eased off and refitted whenever the flow meter is serviced\u003c\/li\u003e\n\u003cli\u003eSunlight and heat, which can harden, yellow and cloud a clear tube\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhat ends its life is a crack or split at an end where it meets a fitting, a kink or flattening at the hook or the S-curve, hardening that stops the ends gripping, or residue inside the tube that no longer flushes out.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚙️ Functional Purpose\u003c\/h2\u003e\n\u003cp\u003eThe outlet hose's engineering role is to deliver every measured litre onward without losing any of it. It does that in three ways:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrying\u003c\/strong\u003e — the tube carries liquid from the meter's outlet port onward along the spray line\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHolding a clear bore\u003c\/strong\u003e — the formed S-curve and hook keep the bore round through the turns, so the liquid is not squeezed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSealing\u003c\/strong\u003e — each end grips its fitting tightly, so measured liquid stays in the line\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe position matters because of what the meter can and cannot see. The flow meter reports the liquid that passes through it. Liquid that escapes from the outlet hose has already passed through the meter, so it has already been counted. The meter has no way of knowing that some of what it counted dripped out on the far side.\u003c\/p\u003e\n\u003cp\u003eThat makes the outlet hose's seal part of the accuracy of the spray record. A sound outlet hose means the metered quantity is the quantity that goes on along the line. A weeping outlet hose means the record shows more product applied than reached the spraying outputs.\u003c\/p\u003e\n\u003cp\u003eWhat the outlet hose does not do:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIt does not measure anything; the flow meter does that\u003c\/li\u003e\n\u003cli\u003eIt does not carry any signal; the flow meter's signal cable does that\u003c\/li\u003e\n\u003cli\u003eIt does not feed the meter; the Flow Meter Water Inlet Hose does that\u003c\/li\u003e\n\u003cli\u003eIt does not replace the spray-boom hoses; those are a separate part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 Diagnosis — a leak after the meter has already been counted, so the reading stays normal\u003c\/h2\u003e\n\u003cp\u003eMost spraying-system faults show up on the remote controller. A blocked filter, a weak pump or a kinked inlet hose changes what reaches the meter, and the flow reading changes with it. A leak on the outlet hose does not do that.\u003c\/p\u003e\n\u003cp\u003eThe meter measures the liquid as it passes through. If the outlet hose then weeps at an end or splits at its hook, the liquid lost there has already been counted. The flow reading stays normal, the job record shows the full quantity applied, and the shortfall only shows up later: a tank that empties sooner than the record suggests, a field edge that looks under-treated, or residue and damp collecting below the meter.\u003c\/p\u003e\n\u003cp\u003eThat is why this hose is checked by eye and by hand, not by reading the controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe fault pattern that points at the outlet hose:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDamp, drips or dried residue below the flow meter or along the outlet hose, with a normal flow reading\u003c\/li\u003e\n\u003cli\u003eA tank that empties faster than the recorded application suggests\u003c\/li\u003e\n\u003cli\u003eA visible crack or split at either end of the hose, often where it meets a fitting\u003c\/li\u003e\n\u003cli\u003eA kink, flat spot or white stress line at the hook or the S-curve\u003c\/li\u003e\n\u003cli\u003eA hose that has gone cloudy, yellowed or hard and no longer grips its fittings\u003c\/li\u003e\n\u003cli\u003eResidue built up inside the clear tube that does not flush out\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInspect it this way:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFill the tank with clean water and run the spraying system on the ground with the meter area open\u003c\/li\u003e\n\u003cli\u003eWipe both ends of the outlet hose with a dry tissue while it runs and look for damp\u003c\/li\u003e\n\u003cli\u003eLook through the clear wall along its whole length, paying most attention to the hook and the S-curve\u003c\/li\u003e\n\u003cli\u003eCompare the water used on the ground run with the quantity the flow reading reports; a gap with a wet outlet hose points here\u003c\/li\u003e\n\u003cli\u003eFeel the hose; a hose that has gone hard or brittle no longer seals well\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSigns that point somewhere else:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe flow reading itself is wrong or unsteady — look upstream: the inlet hose, the filters, the flow meter and its signal cable\u003c\/li\u003e\n\u003cli\u003eBubbles in the liquid entering the meter — that is the inlet side, not this hose\u003c\/li\u003e\n\u003cli\u003eThe leak is at the spray boom — that is the Spray Hose (2 sets), not this one\u003c\/li\u003e\n\u003cli\u003eThe outlet hose is dry and sound, and the meter body itself is cracked or wet — that is the Flow Meter Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWipe the outlet hose ends on a ground run first, while that information is still cheap. It is the one leak on the spraying system that the flow reading cannot report.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚠️ Common Replacement Indicators\u003c\/h2\u003e\n\u003cp\u003eReplace the outlet hose when inspection confirms one of these:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDamp or residue at either end that returns after the end is cleaned and refitted\u003c\/li\u003e\n\u003cli\u003eA crack or split at either end\u003c\/li\u003e\n\u003cli\u003eA kink, flat spot or white stress line at the hook or the S-curve\u003c\/li\u003e\n\u003cli\u003eA hose that has gone hard, brittle, cloudy or yellowed\u003c\/li\u003e\n\u003cli\u003eResidue inside it that does not flush out with clean water\u003c\/li\u003e\n\u003cli\u003eAny previous repair made with a length of straight tube bent into place\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInspect these as well, because they produce similar symptoms:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe sealing rings and fittings at each end of the hose\u003c\/li\u003e\n\u003cli\u003eThe flow meter body and its ports\u003c\/li\u003e\n\u003cli\u003eThe Flow Meter Water Inlet Hose on the other side of the meter\u003c\/li\u003e\n\u003cli\u003eThe spray-boom hoses further along the line\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThere is no published service interval for the outlet hose. It is inspected whenever the flow meter is serviced and replaced when it leaks, kinks or degrades.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e📐 Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name:\u003c\/strong\u003e DJI Talos T60X OEM Flow Meter Water Outlet Hose\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDJI family:\u003c\/strong\u003e Talos\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAircraft:\u003c\/strong\u003e Talos T60X\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitment basis:\u003c\/strong\u003e Identified for the Talos T60X\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVariant:\u003c\/strong\u003e Talos T60X\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAircraft system:\u003c\/strong\u003e Spraying system — flow meter outlet\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent type:\u003c\/strong\u003e Flow meter water outlet hose (pre-formed)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial number:\u003c\/strong\u003e Not published for this part — Send us a photograph of the label on the part you removed and we will match it before it ships.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 hose\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAppearance:\u003c\/strong\u003e Clear translucent white tube with a long, nearly straight leg, a shallow S-curve and a tight hook turning the far end upward, as photographed\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLength:\u003c\/strong\u003e Not published for this part — compare with the hose you removed\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBore:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWorking rating:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical:\u003c\/strong\u003e None — the flow meter's signal is carried by its own cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting position:\u003c\/strong\u003e On the outlet side of the flow meter, between the meter's outlet port and the spray line onward\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation method:\u003c\/strong\u003e Ends pushed fully onto their fittings in the same orientation as the part removed, with the hook at the same end and the S-curve stepping the same way\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded hardware:\u003c\/strong\u003e None — clamps and sealing rings are separate\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePaired part:\u003c\/strong\u003e Flow Meter Water Inlet Hose, on the inlet side of the same meter, supplied separately\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eService adjustability:\u003c\/strong\u003e None — the part is correct or it is not, with no adjustment or app setting that compensates\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClassification:\u003c\/strong\u003e DJI OEM spraying-system hose\u003c\/p\u003e\n\n\u003chr\u003e\n\u003ch2\u003e🛠️ Installation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower the aircraft down and remove the battery\u003c\/li\u003e\n\u003cli\u003eDrain the spray tank and rinse the spraying system with clean water\u003c\/li\u003e\n\u003cli\u003ePhotograph the outlet hose in place, showing which end the hook is at and which way the S-curve steps\u003c\/li\u003e\n\u003cli\u003eConfirm the hose you are replacing comes off the meter's outlet port, not its inlet port\u003c\/li\u003e\n\u003cli\u003eLay the new hose beside the old one and confirm the length, the S-curve and the hook match\u003c\/li\u003e\n\u003cli\u003eHave new sealing rings or clamps ready if the old ones are worn\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDuring installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRelease any clamp at each end and keep it; clamps are not included\u003c\/li\u003e\n\u003cli\u003eEase each end off its fitting along its length rather than levering it sideways\u003c\/li\u003e\n\u003cli\u003eCatch the liquid left in the line\u003c\/li\u003e\n\u003cli\u003eClean both fittings and look for cracks or residue on them\u003c\/li\u003e\n\u003cli\u003eFit the new hose with the hook at the same end and the S-curve stepping the same way as the old one\u003c\/li\u003e\n\u003cli\u003ePush each end fully onto its fitting and refit the clamps\u003c\/li\u003e\n\u003cli\u003eCheck the hose sits naturally along its route with no twist and nothing pressing on the hook\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAfter installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLook along the hose and confirm the hook and the S-curve are round and open, with no flattening\u003c\/li\u003e\n\u003cli\u003eRun clean water through the system on the ground\u003c\/li\u003e\n\u003cli\u003eWipe both ends of the outlet hose with a dry tissue while it runs and look for damp\u003c\/li\u003e\n\u003cli\u003eLeave a dry tissue under the meter for the ground run and check it afterwards\u003c\/li\u003e\n\u003cli\u003ePower up and confirm there are no spraying-system warnings on the remote controller\u003c\/li\u003e\n\u003cli\u003eRecord the replacement in the maintenance log\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance between jobs.\u003c\/strong\u003e Flush the spraying system with clean water at the end of every spray day so residue does not settle in the clear hose. Whenever the meter area is open, wipe the outlet hose ends and look for dried residue below the meter; this is the hose whose leak the flow reading will not show you.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🚜 Necessary For\u003c\/h2\u003e\n\u003cp\u003eThe outlet hose is for operators and technicians who need the metered quantity to be the applied quantity on the Talos T60X:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTalos T60X operators finding damp or residue below the flow meter\u003c\/li\u003e\n\u003cli\u003eOperators whose tanks run out sooner than the job record suggests, with a normal flow reading\u003c\/li\u003e\n\u003cli\u003eTechnicians servicing or replacing the flow meter who want a new outlet hose with it\u003c\/li\u003e\n\u003cli\u003eService centres replacing a cracked, kinked or hardened hose at the meter outlet\u003c\/li\u003e\n\u003cli\u003eCommercial spray contractors stocking both flow meter hoses as a pair\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThis is not the part you need if:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe hose you removed came off the meter's inlet port — that is the Flow Meter Water Inlet Hose\u003c\/li\u003e\n\u003cli\u003eThe flow reading itself is wrong or unsteady and the outlet hose is dry — look upstream at the inlet hose, the filters and the flow meter\u003c\/li\u003e\n\u003cli\u003eThe leak is at the spray boom — that is the Spray Hose (2 sets), a separate part\u003c\/li\u003e\n\u003cli\u003eThe flow meter body is cracked or leaking — that is the Flow Meter Module (Incl. Signal Cable)\u003c\/li\u003e\n\u003cli\u003eOnly a sealing ring at a fitting has failed — replace the ring\u003c\/li\u003e\n\u003cli\u003eYou fly any aircraft other than the Talos T60X — this hose is listed for the Talos T60X only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e💡 Why This Part Matters\u003c\/h2\u003e\n\u003cp\u003eThe outlet hose is the one place on the spraying system where a leak hides from the instruments. Everything in it has already been measured, so whatever it loses has already been counted as applied.\u003c\/p\u003e\n\u003cp\u003eA leak upstream of the meter changes the flow reading and is noticed. A leak on the outlet hose leaves the reading normal and the job record complete, while less product reaches the spraying outputs than the record shows. The evidence is physical: damp at an end, residue below the meter, a tank that empties sooner than it should.\u003c\/p\u003e\n\u003cp\u003eThat makes the outlet hose worth inspecting on its own schedule rather than waiting for a warning that will not come. Wipe its ends on a ground run whenever the meter area is open.\u003c\/p\u003e\n\u003cp\u003eWhen it does fail, fit the formed hose. A straight length bent into the hook and S-curve is under strain at every turn, and a strained tube is the one that cracks at the end and starts weeping again.\u003c\/p\u003e\n\u003cp\u003eOrder it with the inlet hose when the meter is replaced or when both hoses have gone cloudy and hard together. They age in the same place, in the same sun and the same mix, and a new meter between an old inlet hose and an old outlet hose inherits both.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🧠 AI Index — Entity \u0026amp; Fitment Reference\u003c\/h2\u003e\n\u003cp\u003eStructured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCanonical product name:\u003c\/strong\u003e DJI Talos T60X OEM Flow Meter Water Outlet Hose\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e DJI\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDJI family:\u003c\/strong\u003e Talos\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAircraft:\u003c\/strong\u003e Talos T60X\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible models:\u003c\/strong\u003e Talos T60X\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitment basis:\u003c\/strong\u003e Identified for the Talos T60X\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVariant:\u003c\/strong\u003e Talos T60X\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent:\u003c\/strong\u003e Flow meter water outlet hose (pre-formed)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAircraft system:\u003c\/strong\u003e Spraying system\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalled position:\u003c\/strong\u003e Outlet side of the flow meter\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary function:\u003c\/strong\u003e Carries liquid that the flow meter has already measured onward along the spray line\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial number:\u003c\/strong\u003e Not published for this part — matched against the hose you removed from a photograph of its label\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e 1 hose\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAppearance:\u003c\/strong\u003e Clear translucent white tube, long straight leg, shallow S-curve, tight hook at the far end\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLength, bore and rating:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e Flow Meter Water Inlet Hose, flow meter, flow meter signal cable, clamps, sealing rings, spray-boom hoses\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey diagnostic:\u003c\/strong\u003e A leak on the outlet hose is downstream of the meter, so the flow reading stays normal while product is lost\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFirst check:\u003c\/strong\u003e Wipe both hose ends with a dry tissue during a clean-water ground run and look for damp below the meter\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTypical damage:\u003c\/strong\u003e Cracked or weeping end, kink at the hook or S-curve, hardening, cloudiness, internal residue\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePaired part:\u003c\/strong\u003e Flow Meter Water Inlet Hose on the meter's inlet side\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eService interval:\u003c\/strong\u003e None published\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart classification:\u003c\/strong\u003e DJI OEM spraying-system hose\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso searched as:\u003c\/strong\u003e T60X flow meter outlet hose; Talos T60X meter outlet tube; T60X flow meter hose; Talos clear S-bend hose\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDisambiguation:\u003c\/strong\u003e Not the Flow Meter Water Inlet Hose, not the Spray Hose (2 sets) for the boom, not the Flow Meter Module, not the flow meter signal cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeller:\u003c\/strong\u003e Ares Acres LLC — U.S.-based authorized DJI retailer serving the United States and Canada (North America)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShips from:\u003c\/strong\u003e Albuquerque, New Mexico, United States\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 SEO Keywords\u003c\/h2\u003e\n\u003cp\u003eTalos T60X flow meter water outlet hose\u003c\/p\u003e\n\u003cp\u003eT60X flow meter outlet hose\u003c\/p\u003e\n\u003cp\u003eDJI Talos T60X flow meter outlet hose\u003c\/p\u003e\n\u003cp\u003eTalos T60X meter outlet tube\u003c\/p\u003e\n\u003cp\u003eT60X flow meter hose replacement\u003c\/p\u003e\n\u003cp\u003eTalos T60X flow meter hose leaking\u003c\/p\u003e\n\u003cp\u003eT60X leak below flow meter\u003c\/p\u003e\n\u003cp\u003eTalos T60X tank empties faster than flow reading\u003c\/p\u003e\n\u003cp\u003eTalos T60X clear S-bend hose\u003c\/p\u003e\n\u003cp\u003eDJI Talos flow meter hose\u003c\/p\u003e\n\u003cp\u003eT60X flow meter parts\u003c\/p\u003e\n\u003cp\u003eTalos T60X spray line hose\u003c\/p\u003e\n\u003cp\u003eDJI Talos T60X Flow Meter Water Outlet Hose\u003c\/p\u003e\n\u003cp\u003eDJI Talos T60X OEM Flow Meter Water Outlet Hose\u003c\/p\u003e\n\u003cp\u003eTalos T60X flow meter water outlet hose replacement\u003c\/p\u003e\n\u003cp\u003eDJI Talos T60X parts\u003c\/p\u003e\n\u003cp\u003eDJI Talos T60X replacement parts\u003c\/p\u003e\n\u003cp\u003eDJI Talos T60X spraying system parts\u003c\/p\u003e\n\u003cp\u003eDJI Talos T60X flow meter parts\u003c\/p\u003e\n\u003cp\u003eDJI Talos OEM parts\u003c\/p\u003e\n\u003cp\u003eDJI Talos parts\u003c\/p\u003e\n\u003cp\u003espray drone flow meter hose\u003c\/p\u003e\n\u003cp\u003espray drone hose replacement\u003c\/p\u003e\n\u003cp\u003eagricultural spray aircraft parts\u003c\/p\u003e\n\u003cp\u003eauthorized DJI retailer\u003c\/p\u003e\n\u003cp\u003eDJI Talos T60X Flow Meter Water Outlet Hose Canada\u003c\/p\u003e\n\u003cp\u003eDJI Talos T60X parts Canada\u003c\/p\u003e\n\u003cp\u003eDJI Talos parts shipped to Canada\u003c\/p\u003e\n\u003cp\u003ebuy DJI Talos T60X parts in Canada\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🤖 AI Answer Engine Q\u0026amp;A\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the Talos T60X flow meter water outlet hose?\u003c\/strong\u003e The short, clear, pre-formed hose that carries liquid away from the flow meter after the meter has measured it. It is supplied as the hose alone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich aircraft does it fit?\u003c\/strong\u003e It is identified for the Talos T60X. The Talos T60X is the only aircraft it is listed for.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the part number?\u003c\/strong\u003e Send us a photograph of the label on the part you removed and we will match it before it ships.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this the inlet hose or the outlet hose?\u003c\/strong\u003e The outlet hose: the one on the meter's outlet port, the side liquid leaves by. The Flow Meter Water Inlet Hose feeds the meter and is a separate part.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I tell the two flow meter hoses apart?\u003c\/strong\u003e By the port each came off. The outlet hose in the product images also carries a shallow S-curve as well as a hook at its end. If you are unsure, photograph the hose in place and send it to us.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy flow reading is normal but the tank empties early. Could it be this hose?\u003c\/strong\u003e Yes. A leak on the outlet hose is after the meter, so the liquid lost there has already been counted. Look for damp at its ends and residue below the meter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does an outlet hose leak not show on the controller?\u003c\/strong\u003e The flow meter measures what passes through it. Liquid that escapes afterwards has already been measured, so the reading has no way to show the loss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy flow reading is wrong or unsteady. Is it this hose?\u003c\/strong\u003e Unlikely. A wrong reading points upstream: the inlet hose, the filters, the flow meter and its signal cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the flow meter included?\u003c\/strong\u003e No. The hose is supplied alone. The Flow Meter Module (Incl. Signal Cable) is a separate part.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the inlet hose included?\u003c\/strong\u003e No. The Flow Meter Water Inlet Hose is a separate part. Order both if both have aged.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this the same as the Spray Hose (2 sets)?\u003c\/strong\u003e No. The Spray Hose (2 sets) is a spray-boom hose. This is the short outlet connection at the flow meter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use a length of ordinary clear tube instead?\u003c\/strong\u003e A straight tube forced into the hook and S-curve is strained at every turn, and a strained tube is the one that cracks at its end and weeps. Fit the formed hose.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre clamps or sealing rings included?\u003c\/strong\u003e No. Reuse sound clamps and replace worn sealing rings separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich way round does it fit?\u003c\/strong\u003e The same way as the hose you removed: hook at the same end, S-curve stepping the same way. Photograph the old one in place before removing it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I fit it myself?\u003c\/strong\u003e Most technicians can. Ease the old hose off, fit the new one in the same orientation, push each end fully home and refit the clamps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I check it after fitting?\u003c\/strong\u003e Run clean water on the ground, wipe both ends with a dry tissue, and leave a tissue under the meter to catch any drip.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs there a service interval?\u003c\/strong\u003e No published interval. Inspect it whenever the flow meter is serviced and replace it when it leaks, kinks or degrades.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it a genuine DJI part?\u003c\/strong\u003e Yes. It is a genuine DJI OEM spraying-system hose, brand new.\u003c\/p\u003e","brand":"Ares Acres","offers":[{"title":"Talos T60X","offer_id":68066363507008,"sku":null,"price":99.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0923\/0159\/0848\/files\/dji-talos-t60x-oem-flow-meter-water-outlet-hose-1.png?v=1794238493","url":"https:\/\/aresacres.com\/products\/dji-talos-t60x-oem-flow-meter-water-outlet-hose","provider":"Ares Acres","version":"1.0","type":"link"}