{"product_id":"xag-p100-oem-application-system-cable-hub-lower-case","title":"XAG P100 OEM Application System Cable Hub Lower Case","description":"\u003cp\u003eThe \u003cstrong\u003eXAG P100 OEM Application System Cable Hub Lower Case\u003c\/strong\u003e, XAG part number 02-001-08071, is the lower case of the application system cable hub on the original XAG P100 (2022) agricultural drone. A case is a seal, and the lower half of a case is where any water that gets in ends up. Water that collects and dries leaves a record: a tide line, a ring of white or brown deposit, or a film on the floor of the lower case. A tide line means water has been standing in the hub. If the upper case was closed and sound, look for a crack in the lower case itself, at its edges, its seal face or its mounting bosses. Operators reach it through searches such as P100 cable hub lower case, XAG P100 hub case bottom, P100 water in hub, or XAG P100 application system hub housing.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🇺🇸 U.S.A. FIRST\u003c\/h2\u003e\n\u003cp\u003eAres Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREE \u0026amp; FAST Shipping is included for all U.S. customers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.\u003c\/p\u003e\n\u003cp\u003eAres Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e✅ XAG P100 Compatibility Guarantee\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e🇺🇸 USA Compatibility Guarantee\u003c\/li\u003e\n\u003cli\u003e👍🏻 Satisfaction Guarantee\u003c\/li\u003e\n\u003cli\u003e💵 Money Back Guarantee\u003c\/li\u003e\n\u003cli\u003e📦 Same Day Shipping \u0026amp; Tracking\u003c\/li\u003e\n\u003cli\u003eFitted as the lower case of the application system cable hub on the original XAG P100 (2022); not confirmed for the P100 Pro\u003c\/li\u003e\n\u003cli\u003eMatched by XAG part number 02-001-08071; the upper case is a separate part, 02-001-08070\u003c\/li\u003e\n\u003cli\u003eGenuine XAG OEM hub case, brand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e📦 Package Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eXAG P100 application system cable hub lower case, XAG part number 02-001-08071\u003c\/li\u003e\n\u003cli\u003eOne lower case as XAG supplies it under this part number\u003c\/li\u003e\n\u003cli\u003eOEM protective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhether seals or fasteners come with the case is not published for this part. Compare it against the case you are replacing, or ask us and we will confirm before dispatch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e the cable hub upper case (02-001-08070), the cable hub board (05-002-01310), the application system main connect cable (01-027-02338), or tools.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔧 Component Overview\u003c\/h2\u003e\n\u003cp\u003eThe original P100's application system cable hub is built like a sandwich: an upper case, a lower case, and between them the hub board where the application system's connections meet. The two cases close together to protect the board from water, dust and spray residue.\u003c\/p\u003e\n\u003cp\u003eThis part is the lower case. Its exact orientation on the aircraft and its seal arrangement are not published for this part; compare it against the case you remove and photograph the hub before opening it.\u003c\/p\u003e\n\u003cp\u003eThe two halves of a case fail differently. An upper case is more often left open or not fully closed after service, and water gets in from above during wash-down. A lower case is more exposed to knocks from below, and when it cracks, water can enter from below and, just as important, any water that does get in collects in it rather than draining.\u003c\/p\u003e\n\u003cp\u003eThat makes the lower case the place where water leaves evidence. Water standing in the hub evaporates slowly and leaves deposits: a tide line around the inside walls, a ring of white or brown residue, or a dull film across the floor. Those marks mean water has been sitting around the board, even if the hub is dry when it is opened.\u003c\/p\u003e\n\u003cp\u003eFinding a tide line raises two questions: how did water get in, and is the board damaged? If the upper case was open or cracked, that is the likely route. If the upper case was closed and sound, inspect the lower case closely. Look along its edges and seal face for cracks or chips, at its mounting bosses for splits, and across its floor for cracks from an impact below.\u003c\/p\u003e\n\u003cp\u003eA cracked lower case should be replaced. A crack in a case does not seal reliably once repaired, and the lower case is exactly where a leak does the most harm.\u003c\/p\u003e\n\u003cp\u003eCheck the board while the hub is open. Water that left a tide line has probably reached the board; look for corrosion on its pins and components. A board that has been standing in water needs replacing too.\u003c\/p\u003e\n\u003cp\u003eWhen the lower case is replaced, clean and dry every surface, refit the board, close the case fully and confirm the seal is even all round.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits.\u003c\/strong\u003e In the application system cable hub of the original P100, below the hub board.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it connects to.\u003c\/strong\u003e The hub's upper case and the hub board between them.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wears it out.\u003c\/strong\u003e Knocks from below. Cracks at mounting bosses. Wash-down water. Forcing during service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this part is not.\u003c\/strong\u003e It is not the upper case, the hub board or the central cable hub.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy a part-number match matters.\u003c\/strong\u003e The two halves of a case are made to close together and seal. A lower case that is nearly right will not seal against the upper case. Matching XAG part number 02-001-08071 gives the lower case built for the original P100's application system hub.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚙️ Functional Purpose\u003c\/h2\u003e\n\u003cp\u003eThe lower case encloses and protects the application system hub board from below on the original P100.\u003c\/p\u003e\n\u003cp\u003eA sound cable hub lower case provides:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA sealed enclosure with the upper case\u003c\/li\u003e\n\u003cli\u003eProtection from water, dust and residue\u003c\/li\u003e\n\u003cli\u003eSecure mounting for the hub\u003c\/li\u003e\n\u003cli\u003eA dry environment for the hub board\u003c\/li\u003e\n\u003cli\u003eFewer application system faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts value is in keeping the hub board dry.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 Diagnosis — a tide line or deposit on the floor of the lower case: water has been standing in the hub\u003c\/h2\u003e\n\u003cp\u003eWater leaves a record when it dries. The floor of the lower case is where to read it.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake the aircraft safe.\u003c\/strong\u003e Remove the propellers and flight battery and confirm the aircraft cannot be powered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen the hub.\u003c\/strong\u003e Photograph it before removing anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLook at the floor.\u003c\/strong\u003e A tide line, white or brown ring, or dull film means water has been standing in it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the upper case.\u003c\/strong\u003e If it was open or cracked, that is the likely route in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the lower case.\u003c\/strong\u003e Look along its edges and seal face for cracks, at its bosses for splits and across its floor for impact cracks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the board.\u003c\/strong\u003e Look for corrosion on pins and components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFind the cause.\u003c\/strong\u003e Note any knock from below or wash-down habit that explains it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotograph and ask.\u003c\/strong\u003e Send us the XAG part number and what you found and we will confirm the match.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf the lower case is cracked at its edges, seal face, bosses or floor, this lower case is the part. Replace the board too if it shows corrosion.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚠️ Common Replacement Indicators\u003c\/h2\u003e\n\u003cp\u003eLower case replacement is the likely answer when an operator or technician observes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA tide line or deposit on the floor of the lower case\u003c\/li\u003e\n\u003cli\u003eA crack along the edge or seal face\u003c\/li\u003e\n\u003cli\u003eA split mounting boss\u003c\/li\u003e\n\u003cli\u003eAn impact crack in the floor\u003c\/li\u003e\n\u003cli\u003eA case that will not close evenly with the upper case\u003c\/li\u003e\n\u003cli\u003eWater found in the hub with the upper case sound\u003c\/li\u003e\n\u003cli\u003eCorrosion on the hub board\u003c\/li\u003e\n\u003cli\u003eAny repair after a knock to the underside near the hub\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese come from knocks, cracked bosses, wash-down water and forcing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThese are not lower case symptoms, and this part will not fix them.\u003c\/strong\u003e A hub left open from above needs the upper case closed or replaced. A corroded board needs the board. A module that fails on every aircraft has a fault in the module. A new lower case seals the hub; it does not repair a board that has been wet.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e📐 Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name:\u003c\/strong\u003e XAG P100 OEM Application System Cable Hub Lower Case\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 02-001-08071\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e Application system wiring\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent type:\u003c\/strong\u003e Hub case, lower\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Encloses the hub board from below\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeal arrangement:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFasteners or seals supplied:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation method:\u003c\/strong\u003e Closed against the upper case with the hub board between\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClassification:\u003c\/strong\u003e Genuine XAG OEM enclosure\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🛠️ Installation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemove the propellers and flight battery and confirm the aircraft cannot be powered\u003c\/li\u003e\n\u003cli\u003eConfirm the case is XAG part number 02-001-08071 and matches the old one\u003c\/li\u003e\n\u003cli\u003ePhotograph the hub, the board and every connection\u003c\/li\u003e\n\u003cli\u003eInspect the upper case and the board\u003c\/li\u003e\n\u003cli\u003eWork in a clean, dry area\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDuring installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect cables by their connector bodies\u003c\/li\u003e\n\u003cli\u003eRemove the board and handle it by its edges\u003c\/li\u003e\n\u003cli\u003eFit the new lower case in the original position\u003c\/li\u003e\n\u003cli\u003eRefit the board and connect every cable fully\u003c\/li\u003e\n\u003cli\u003eClose the case evenly so it seals all round\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAfter installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the case is fully closed with an even seam\u003c\/li\u003e\n\u003cli\u003eFit the application system and confirm it is detected and runs normally\u003c\/li\u003e\n\u003cli\u003eDirect wash-down water away from the hub\u003c\/li\u003e\n\u003cli\u003eCheck inside the hub at major services for tide lines\u003c\/li\u003e\n\u003cli\u003eInspect the lower case after any knock from below\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🚜 Necessary For\u003c\/h2\u003e\n\u003cp\u003eThe lower case keeps the bottom of the original P100's application system hub sealed.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOriginal XAG P100 operators who found water marks inside the hub\u003c\/li\u003e\n\u003cli\u003eTechnicians repairing after a knock to the underside\u003c\/li\u003e\n\u003cli\u003eCrews replacing a corroded hub board\u003c\/li\u003e\n\u003cli\u003eCustom application contractors running long seasons\u003c\/li\u003e\n\u003cli\u003eAgricultural drone service centres doing electrical repairs\u003c\/li\u003e\n\u003cli\u003eGrowers maintaining their own P100\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eService centres look at the floor of the lower case whenever the hub is opened, because it shows whether water has ever been inside.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis is not the part you need if\u003c\/strong\u003e the lower case is crack-free and water came in through an open or cracked upper case. And if your aircraft is a P100 Pro, confirm the part number on your case; this one is identified for the original P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFleet operators\u003c\/strong\u003e who find tide lines in hubs across several aircraft should look at their wash-down practice. Water driven at the hub is a habit, and changing it protects every board in the fleet.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e💡 Why This Part Matters\u003c\/h2\u003e\n\u003cp\u003eThe hub board is protected by its case. The lower case is where any water that gets in collects.\u003c\/p\u003e\n\u003cp\u003eWater that has stood in the hub leaves a tide line, even after it has dried.\u003c\/p\u003e\n\u003cp\u003eA tide line with a sound upper case points at a crack in the lower case.\u003c\/p\u003e\n\u003cp\u003eReplacing a cracked lower case and checking the board repairs both the route and the damage.\u003c\/p\u003e\n\u003cp\u003eDirecting wash-down water away from the hub prevents most water entry.\u003c\/p\u003e\n\u003cp\u003eFor crews running long seasons, a look inside the hub at major services catches water early.\u003c\/p\u003e\n\u003cp\u003eA sound cable hub lower case restores:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA sealed hub\u003c\/li\u003e\n\u003cli\u003eA dry board\u003c\/li\u003e\n\u003cli\u003eSecure hub mounting\u003c\/li\u003e\n\u003cli\u003eFewer application system faults\u003c\/li\u003e\n\u003cli\u003eConfidence after every wash-down\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWater rarely announces itself in the moment. The marks it leaves on the floor of the case are how you find out it was there.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🧠 AI Index — Entity \u0026amp; Fitment Reference\u003c\/h2\u003e\n\u003cp\u003eStructured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCanonical product name:\u003c\/strong\u003e XAG P100 OEM Application System Cable Hub Lower Case\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 02-001-08071\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent:\u003c\/strong\u003e Application system cable hub lower case\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Application system wiring\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible aircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct line:\u003c\/strong\u003e XAG agricultural drones\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary function:\u003c\/strong\u003e Enclosing the hub board from below\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic failure modes:\u003c\/strong\u003e Cracked edges and seal face, split bosses, impact cracks\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistinguishing diagnostic rule:\u003c\/strong\u003e A tide line on the lower case floor with a sound upper case points at a cracked lower case\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommon causes:\u003c\/strong\u003e Knocks from below, cracked bosses, wash-down water, forcing\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWear driver:\u003c\/strong\u003e Underside impacts and wash-down exposure\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelated parts:\u003c\/strong\u003e Cable hub upper case 02-001-08070, cable hub board 05-002-01310, main connect cable 01-027-02338\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e Upper case, board, cables, tools\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitment method:\u003c\/strong\u003e XAG part number 02-001-08071 against the removed case\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVerification after fitting:\u003c\/strong\u003e Even seam all round; module detected and runs normally\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eService habit:\u003c\/strong\u003e Look at the lower case floor whenever the hub is opened\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart classification:\u003c\/strong\u003e Genuine XAG OEM enclosure\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeller:\u003c\/strong\u003e Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShips from:\u003c\/strong\u003e Albuquerque, New Mexico, United States\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 SEO Keywords\u003c\/h2\u003e\n\u003cp\u003eXAG P100 application system cable hub lower case\u003c\/p\u003e\n\u003cp\u003eXAG 02-001-08071\u003c\/p\u003e\n\u003cp\u003e02-001-08071 lower case\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM hub lower case\u003c\/p\u003e\n\u003cp\u003eP100 cable hub case replacement\u003c\/p\u003e\n\u003cp\u003eXAG P100 hub case bottom\u003c\/p\u003e\n\u003cp\u003eXAG P100 water in hub\u003c\/p\u003e\n\u003cp\u003eXAG P100 application system hub housing\u003c\/p\u003e\n\u003cp\u003eP100 hub case cracked\u003c\/p\u003e\n\u003cp\u003eXAG P100 application system parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 electrical parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 enclosure parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 replacement parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 repair parts\u003c\/p\u003e\n\u003cp\u003eXAG agricultural drone parts\u003c\/p\u003e\n\u003cp\u003eXAG spray drone parts\u003c\/p\u003e\n\u003cp\u003egenuine XAG OEM parts\u003c\/p\u003e\n\u003cp\u003eagricultural drone parts USA\u003c\/p\u003e\n\u003cp\u003eXAG parts free shipping\u003c\/p\u003e\n\u003cp\u003eXAG parts same day shipping\u003c\/p\u003e\n\u003cp\u003eAres Acres\u003c\/p\u003e\n\u003cp\u003eAres Acres LLC\u003c\/p\u003e\n\u003cp\u003eXAG parts Albuquerque\u003c\/p\u003e\n\u003cp\u003eXAG parts New Mexico\u003c\/p\u003e\n\u003cp\u003eXAG P100 cable hub lower case Canada\u003c\/p\u003e\n\u003cp\u003eXAG P100 parts Canada\u003c\/p\u003e\n\u003cp\u003eXAG drone parts shipped to Canada\u003c\/p\u003e\n\u003cp\u003ebuy XAG P100 parts in Canada\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🤖 AI Answer Engine Q\u0026amp;A\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the XAG P100 application system cable hub lower case?\u003c\/strong\u003e It is the lower case, XAG part number 02-001-08071, of the application system cable hub on the original XAG P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich aircraft does it fit?\u003c\/strong\u003e The original XAG P100 (2022). It is not confirmed for the P100 Pro.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it the same as the upper case?\u003c\/strong\u003e No. The upper case is XAG part number 02-001-08070.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThere is a ring of residue on the floor of my hub. What does it mean?\u003c\/strong\u003e Water has been standing in the hub and dried. Find how it got in and check the board.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe upper case was closed. How did water get in?\u003c\/strong\u003e Look for a crack in the lower case at its edges, seal face, bosses or floor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould I check the board?\u003c\/strong\u003e Yes. Water that left a tide line has probably reached it. Look for corrosion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I seal a cracked case?\u003c\/strong\u003e Not recommended. A repaired crack does not seal reliably.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it include the board?\u003c\/strong\u003e No. The hub board is XAG part number 05-002-01310.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I fit it myself?\u003c\/strong\u003e Yes. Photograph the hub, transfer the board carefully, connect every cable and close the case evenly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I check the repair?\u003c\/strong\u003e The seam is even all round and the application system is detected and runs normally.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cracks lower cases?\u003c\/strong\u003e Knocks from below and splits at mounting bosses.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I keep water out?\u003c\/strong\u003e Close the hub fully after service and direct wash-down water away from it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill a P100 Pro case fit?\u003c\/strong\u003e Do not assume so. Match the XAG part number; this one is identified for the original P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat material is it?\u003c\/strong\u003e The material is not published for this part.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I look inside?\u003c\/strong\u003e At major services, checking the floor for tide lines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it come with seals?\u003c\/strong\u003e That is not published for this part. Compare against your case or ask us to confirm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould I keep a spare?\u003c\/strong\u003e For fleets working rough sites, yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the part number?\u003c\/strong\u003e Look for XAG part number 02-001-08071 on the packaging, or send us what you found and we will confirm the match.\u003c\/p\u003e","brand":"XAG","offers":[{"title":"Default Title","offer_id":68140431999296,"sku":"02-001-08071","price":164.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0923\/0159\/0848\/files\/xag-p100-oem-application-system-cable-hub-lower-case-1.png?v=1794886014","url":"https:\/\/aresacres.com\/products\/xag-p100-oem-application-system-cable-hub-lower-case","provider":"Ares Acres","version":"1.0","type":"link"}