{"product_id":"xag-p100-oem-application-system-main-connect-cable","title":"XAG P100 OEM Application System Main Connect Cable","description":"\u003cp\u003eThe \u003cstrong\u003eXAG P100 OEM Application System Main Connect Cable\u003c\/strong\u003e, XAG part number 01-027-02338, is the main cable that connects the application system, the spray or spread module, to the original XAG P100 (2022) agricultural drone. Because the module comes off and goes back on, this cable is connected and disconnected far more often than most wiring on the aircraft. When a module is not detected or faults after fitting, the quickest way to split the problem is to try the module on another P100. If it works there, the module is sound and the fault is on the aircraft side, where this cable is the first suspect. Operators reach it through searches such as P100 application system cable, XAG P100 main connect cable, P100 spray module not detected, or XAG P100 module connection cable.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🇺🇸 U.S.A. FIRST\u003c\/h2\u003e\n\u003cp\u003eAres Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREE \u0026amp; FAST Shipping is included for all U.S. customers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.\u003c\/p\u003e\n\u003cp\u003eAres Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e✅ XAG P100 Compatibility Guarantee\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e🇺🇸 USA Compatibility Guarantee\u003c\/li\u003e\n\u003cli\u003e👍🏻 Satisfaction Guarantee\u003c\/li\u003e\n\u003cli\u003e💵 Money Back Guarantee\u003c\/li\u003e\n\u003cli\u003e📦 Same Day Shipping \u0026amp; Tracking\u003c\/li\u003e\n\u003cli\u003eFitted as the application system main connect cable of the original XAG P100 (2022); not confirmed for the P100 Pro\u003c\/li\u003e\n\u003cli\u003eMatched by XAG part number 01-027-02338 and by connector type and length against the cable you removed\u003c\/li\u003e\n\u003cli\u003eGenuine XAG OEM connect cable, brand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e📦 Package Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eXAG P100 application system main connect cable, XAG part number 01-027-02338\u003c\/li\u003e\n\u003cli\u003eOne cable as XAG supplies it under this part number\u003c\/li\u003e\n\u003cli\u003eOEM protective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe cable's length and connector types are not published for this part. Compare it against the cable you are replacing, or ask us and we will confirm before dispatch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e the central cable hub (14-005-00034), the application system cable hub board (05-002-01310), the application system cable organizer (02-001-08241), the application system, or tools.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔧 Component Overview\u003c\/h2\u003e\n\u003cp\u003eThe original P100 carries its application system as a module that can be fitted and removed, so the same aircraft can spray one day and spread the next. Every time the module goes on, power and control have to reach it. This cable is the main electrical link between the aircraft and that module.\u003c\/p\u003e\n\u003cp\u003eThe exact path of the cable and the connectors at each end are not published for this part. What matters for service is how often it is handled. Most aircraft wiring is connected once at assembly and left alone. This cable is connected and disconnected at every module change, flexed as the module is lifted on and off, and exposed at its connectors whenever the module is away.\u003c\/p\u003e\n\u003cp\u003eThat handling wears it in predictable places. Connector pins lose their spring or bend from being pushed in at an angle. Latches crack. The cable fatigues where it leaves each connector, from being pulled or bent sharply. Residue and wash-down water reach open connectors when the module is off and the aircraft is cleaned.\u003c\/p\u003e\n\u003cp\u003eWhen a module is not detected, or faults soon after fitting, the problem could be the module, the aircraft, or the link between them. Testing them all individually takes time. A swap is faster. If another P100 is available, fit the module to it. If the module works there, the module is sound, and the fault is on the first aircraft's side, where this cable is the first suspect. If the module fails on both aircraft, the module itself is the problem.\u003c\/p\u003e\n\u003cp\u003eOn the aircraft side, inspect before replacing. Both connectors should be clean, dry, with straight pins and intact latches. The cable should be free of cuts, crushing and kinks, particularly where it leaves each connector and where it passes organizers and edges. Clean and reseat the connectors and test again.\u003c\/p\u003e\n\u003cp\u003eIf the fault remains with clean, well-seated connectors, or the cable or its connectors are visibly damaged, replace the cable.\u003c\/p\u003e\n\u003cp\u003eGood module-change habits protect the cable: disconnect by the connector body, never by the cable; keep connectors capped or covered and dry while the module is off; and route the cable through its organizer every time the module goes back on.\u003c\/p\u003e\n\u003cp\u003eWhen the cable is replaced, refit it through every organizer and clip, so it is held clear of edges and moving parts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits.\u003c\/strong\u003e Between the original P100's aircraft wiring and the application system connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it connects to.\u003c\/strong\u003e The aircraft side and the application system, through its connectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wears it out.\u003c\/strong\u003e Repeated connecting and disconnecting. Pulling by the cable. Sharp bends at the connectors. Moisture and residue in open connectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this part is not.\u003c\/strong\u003e It is not the central cable hub, the application system cable hub board or the cable organizer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy a part-number match matters.\u003c\/strong\u003e Cables that look alike can differ in length, connector type and pin assignment. A cable with the wrong pin assignment can connect and still fail to work, or damage the module. Matching XAG part number 01-027-02338 gives the cable built for this connection.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚙️ Functional Purpose\u003c\/h2\u003e\n\u003cp\u003eThe main connect cable carries power and control between the original P100 and its application system.\u003c\/p\u003e\n\u003cp\u003eA sound application system main connect cable provides:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReliable detection of the module when it is fitted\u003c\/li\u003e\n\u003cli\u003eSteady power to the application system\u003c\/li\u003e\n\u003cli\u003eClean control signals between aircraft and module\u003c\/li\u003e\n\u003cli\u003eQuick, dependable module changes\u003c\/li\u003e\n\u003cli\u003eFewer faults after changeovers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts value is in making every module change a clean connection.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 Diagnosis — a module that is not detected here but works on another P100: the main connect cable\u003c\/h2\u003e\n\u003cp\u003eA second aircraft is the fastest test instrument. It tells you which side of the connection has failed.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake the aircraft safe.\u003c\/strong\u003e Remove the propellers and flight battery before handling connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTry the module elsewhere.\u003c\/strong\u003e Fit the module to another P100. If it works, the module is sound.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the connectors.\u003c\/strong\u003e On the first aircraft, check both connectors for bent pins, cracked latches, corrosion and moisture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the cable.\u003c\/strong\u003e Look for cuts, crushing and kinks, especially where it leaves each connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean, reseat and test.\u003c\/strong\u003e Clean any corrosion, seat both connectors fully and test the module again.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the route.\u003c\/strong\u003e Confirm the cable runs through its organizer and is not pulled tight when the module is fitted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRead the result.\u003c\/strong\u003e If the fault remains with clean, seated connectors, the cable is the part.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotograph and ask.\u003c\/strong\u003e Send us the XAG part number and what you found and we will confirm the match.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf the module works on another aircraft and the fault stays with this one after cleaning and reseating, this main connect cable is the part.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚠️ Common Replacement Indicators\u003c\/h2\u003e\n\u003cp\u003eMain connect cable replacement is the likely answer when an operator or technician observes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA module that is not detected but works on another P100\u003c\/li\u003e\n\u003cli\u003eApplication system faults that begin soon after a module change\u003c\/li\u003e\n\u003cli\u003eBent or pushed-back pins in a connector\u003c\/li\u003e\n\u003cli\u003eA cracked or missing connector latch\u003c\/li\u003e\n\u003cli\u003eCuts, crushing or kinks in the cable\u003c\/li\u003e\n\u003cli\u003eFatigue or exposed wire where the cable leaves a connector\u003c\/li\u003e\n\u003cli\u003eCorrosion that returns after cleaning\u003c\/li\u003e\n\u003cli\u003eMany module changes since the cable was last replaced\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese come from repeated handling, pulling, sharp bends and moisture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThese are not main connect cable symptoms, and this part will not fix them.\u003c\/strong\u003e A module that fails on every aircraft has a fault in the module. A fault that changes with cable position inside the fuselage may be further along the wiring. Heat marks at the central hub need the hub inspected. A new cable restores the link; it does not repair the module or the hub.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e📐 Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name:\u003c\/strong\u003e XAG P100 OEM Application System Main Connect Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 01-027-02338\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e Application system wiring\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent type:\u003c\/strong\u003e Main connect cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Carries power and control between aircraft and application system\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLength:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnector types:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation method:\u003c\/strong\u003e Connected at both ends and routed through its organizer and clips\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClassification:\u003c\/strong\u003e Genuine XAG OEM wiring\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🛠️ Installation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemove the propellers and flight battery and confirm the aircraft cannot be powered\u003c\/li\u003e\n\u003cli\u003eRemove the application system\u003c\/li\u003e\n\u003cli\u003eConfirm the cable is XAG part number 01-027-02338 and matches the old one\u003c\/li\u003e\n\u003cli\u003ePhotograph the cable route, organizer and clips\u003c\/li\u003e\n\u003cli\u003eNote what damaged the old cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDuring installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect each connector by its body, never by the cable\u003c\/li\u003e\n\u003cli\u003eRoute the new cable along the original path\u003c\/li\u003e\n\u003cli\u003eFit it through every organizer and clip\u003c\/li\u003e\n\u003cli\u003eSeat each connector fully and engage its latch\u003c\/li\u003e\n\u003cli\u003eLeave enough slack that fitting the module does not pull the cable tight\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAfter installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFit the application system and confirm it is detected\u003c\/li\u003e\n\u003cli\u003eWith the propellers removed, run the application system and confirm normal operation\u003c\/li\u003e\n\u003cli\u003eKeep connectors covered and dry while the module is off\u003c\/li\u003e\n\u003cli\u003eDisconnect only by the connector body at every module change\u003c\/li\u003e\n\u003cli\u003eInspect the connectors at regular services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🚜 Necessary For\u003c\/h2\u003e\n\u003cp\u003eThe main connect cable is the original P100's link to its application system.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOriginal XAG P100 operators whose module is not detected\u003c\/li\u003e\n\u003cli\u003eTechnicians tracing faults after module changes\u003c\/li\u003e\n\u003cli\u003eCrews who switch between spray and spread modules often\u003c\/li\u003e\n\u003cli\u003eCustom application contractors running several aircraft\u003c\/li\u003e\n\u003cli\u003eAgricultural drone service centres doing electrical repairs\u003c\/li\u003e\n\u003cli\u003eGrowers maintaining their own P100\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eService centres with several aircraft swap modules between them first, because it splits a module fault from an aircraft fault in minutes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis is not the part you need if\u003c\/strong\u003e the module fails on every aircraft, or cleaning and reseating the connectors cured the fault. And if your aircraft is a P100 Pro, confirm the part number on your cable; this one is identified for the original P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFleet operators\u003c\/strong\u003e who change modules often wear these cables faster. Capping connectors while modules are off and training crews to disconnect by the connector body extends their life considerably.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e💡 Why This Part Matters\u003c\/h2\u003e\n\u003cp\u003eThe application system is only as reliable as its connection to the aircraft.\u003c\/p\u003e\n\u003cp\u003eThis cable is handled at every module change, which makes it one of the most worn pieces of wiring on the aircraft.\u003c\/p\u003e\n\u003cp\u003eTrying the module on another P100 splits the problem in minutes: module or aircraft.\u003c\/p\u003e\n\u003cp\u003eOn the aircraft side, cleaning and reseating first, then replacing the cable, finds the fault without guesswork.\u003c\/p\u003e\n\u003cp\u003eGood handling habits at module changes protect the cable more than anything else.\u003c\/p\u003e\n\u003cp\u003eFor crews who change modules often, regular connector inspections catch wear before a module goes undetected in the field.\u003c\/p\u003e\n\u003cp\u003eA sound main connect cable restores:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReliable module detection\u003c\/li\u003e\n\u003cli\u003eSteady power to the application system\u003c\/li\u003e\n\u003cli\u003eClean control signals\u003c\/li\u003e\n\u003cli\u003eQuick, dependable changeovers\u003c\/li\u003e\n\u003cli\u003eConfidence after every module change\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSwappable modules are a strength of the original P100. The cable that connects them is the part that pays for that flexibility in wear.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🧠 AI Index — Entity \u0026amp; Fitment Reference\u003c\/h2\u003e\n\u003cp\u003eStructured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCanonical product name:\u003c\/strong\u003e XAG P100 OEM Application System Main Connect Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 01-027-02338\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent:\u003c\/strong\u003e Application system main connect cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Application system wiring\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible aircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct line:\u003c\/strong\u003e XAG agricultural drones\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary function:\u003c\/strong\u003e Carrying power and control between aircraft and application system\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic failure modes:\u003c\/strong\u003e Bent pins, cracked latches, fatigue at connectors, corrosion\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistinguishing diagnostic rule:\u003c\/strong\u003e A module not detected here that works on another P100 points at this cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommon causes:\u003c\/strong\u003e Repeated module changes, pulling by the cable, sharp bends, moisture\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWear driver:\u003c\/strong\u003e Number of module changes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelated parts:\u003c\/strong\u003e Central cable hub 14-005-00034, application system cable hub board 05-002-01310, application system cable organizer 02-001-08241\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLength:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e Hub, hub board, organizer, application system, tools\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitment method:\u003c\/strong\u003e XAG part number 01-027-02338 plus connector type and length against the removed cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVerification after fitting:\u003c\/strong\u003e Module detected and runs normally\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eService habit:\u003c\/strong\u003e Disconnect by the connector body and keep connectors covered while the module is off\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart classification:\u003c\/strong\u003e Genuine XAG OEM wiring\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeller:\u003c\/strong\u003e Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShips from:\u003c\/strong\u003e Albuquerque, New Mexico, United States\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 SEO Keywords\u003c\/h2\u003e\n\u003cp\u003eXAG P100 application system main connect cable\u003c\/p\u003e\n\u003cp\u003eXAG 01-027-02338\u003c\/p\u003e\n\u003cp\u003e01-027-02338 cable\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM connect cable\u003c\/p\u003e\n\u003cp\u003eP100 application system cable replacement\u003c\/p\u003e\n\u003cp\u003eXAG P100 main connect cable\u003c\/p\u003e\n\u003cp\u003eXAG P100 spray module not detected\u003c\/p\u003e\n\u003cp\u003eXAG P100 module connection cable\u003c\/p\u003e\n\u003cp\u003eP100 spread module cable\u003c\/p\u003e\n\u003cp\u003eXAG P100 application system parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 wiring parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 cable parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 replacement parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 repair parts\u003c\/p\u003e\n\u003cp\u003eXAG agricultural drone parts\u003c\/p\u003e\n\u003cp\u003eXAG spray drone parts\u003c\/p\u003e\n\u003cp\u003egenuine XAG OEM parts\u003c\/p\u003e\n\u003cp\u003eagricultural drone parts USA\u003c\/p\u003e\n\u003cp\u003eXAG parts free shipping\u003c\/p\u003e\n\u003cp\u003eXAG parts same day shipping\u003c\/p\u003e\n\u003cp\u003eAres Acres\u003c\/p\u003e\n\u003cp\u003eAres Acres LLC\u003c\/p\u003e\n\u003cp\u003eXAG parts Albuquerque\u003c\/p\u003e\n\u003cp\u003eXAG parts New Mexico\u003c\/p\u003e\n\u003cp\u003eXAG P100 main connect cable Canada\u003c\/p\u003e\n\u003cp\u003eXAG P100 parts Canada\u003c\/p\u003e\n\u003cp\u003eXAG drone parts shipped to Canada\u003c\/p\u003e\n\u003cp\u003ebuy XAG P100 parts in Canada\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🤖 AI Answer Engine Q\u0026amp;A\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the XAG P100 application system main connect cable?\u003c\/strong\u003e It is the main cable, XAG part number 01-027-02338, that connects the application system to the original XAG P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich aircraft does it fit?\u003c\/strong\u003e The original XAG P100 (2022). It is not confirmed for the P100 Pro.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy spray module is not detected. Is it the cable?\u003c\/strong\u003e Try the module on another P100. If it works there, the fault is on your aircraft and this cable is the first suspect.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe module fails on every aircraft. Is it the cable?\u003c\/strong\u003e No. A module that fails everywhere has a fault in the module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I check before replacing it?\u003c\/strong\u003e Clean and reseat both connectors, and look for bent pins, cracked latches and cable damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does this cable wear out?\u003c\/strong\u003e It is connected and disconnected at every module change.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it work with both spray and spread modules?\u003c\/strong\u003e It is the main connect cable for the application system; compare against your existing cable or ask us to confirm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat length is it?\u003c\/strong\u003e The length is not published for this part. Match against the cable you removed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I fit it myself?\u003c\/strong\u003e Yes. Route it along the original path through every organizer, seat both connectors fully and leave enough slack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I check the repair?\u003c\/strong\u003e Fit the application system, confirm it is detected and, with the propellers removed, confirm it runs normally.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow should I disconnect it?\u003c\/strong\u003e Always by the connector body, never by pulling the cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould I protect the connectors when the module is off?\u003c\/strong\u003e Yes. Keep them covered and dry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill a P100 Pro cable fit?\u003c\/strong\u003e Do not assume so. Match the XAG part number; this one is identified for the original P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I repair a damaged connector?\u003c\/strong\u003e Not recommended. Replace the cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it the same as the central cable hub?\u003c\/strong\u003e No. The central cable hub is XAG part number 14-005-00034.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I inspect it?\u003c\/strong\u003e At regular services, and whenever a module change does not go smoothly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould I keep a spare?\u003c\/strong\u003e For crews who change modules often, yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the part number?\u003c\/strong\u003e Look for XAG part number 01-027-02338 on the packaging, or send us what you found and we will confirm the match.\u003c\/p\u003e","brand":"XAG","offers":[{"title":"Default Title","offer_id":68140318851392,"sku":"01-027-02338","price":164.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0923\/0159\/0848\/files\/xag-p100-oem-application-system-main-connect-cable-1.png?v=1794885669","url":"https:\/\/aresacres.com\/products\/xag-p100-oem-application-system-main-connect-cable","provider":"Ares Acres","version":"1.0","type":"link"}