{"product_id":"xag-p100-oem-battery-socket","title":"XAG P100 OEM Battery Socket","description":"\u003cp\u003eThe \u003cstrong\u003eXAG P100 OEM Battery Socket\u003c\/strong\u003e, XAG part number 14-005-00027, is the main battery socket on the original XAG P100 agricultural drone — the connector the flight battery plugs into, and the point where every amp the aircraft uses passes from the battery into the airframe. Operators reach it through searches such as P100 battery socket, XAG P100 battery connector, P100 power cuts out under load, or XAG P100 burnt battery terminal.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🇺🇸 U.S.A. FIRST\u003c\/h2\u003e\n\u003cp\u003eAres Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREE \u0026amp; FAST Shipping is included for all U.S. customers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.\u003c\/p\u003e\n\u003cp\u003eAres Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e✅ XAG P100 Compatibility Guarantee\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e🇺🇸 USA Compatibility Guarantee\u003c\/li\u003e\n\u003cli\u003e👍🏻 Satisfaction Guarantee\u003c\/li\u003e\n\u003cli\u003e💵 Money Back Guarantee\u003c\/li\u003e\n\u003cli\u003e📦 Same Day Shipping \u0026amp; Tracking\u003c\/li\u003e\n\u003cli\u003eFitted at the battery bay of the original XAG P100 (2022); not confirmed for the P100 Pro\u003c\/li\u003e\n\u003cli\u003eMatched by XAG part number 14-005-00027 and by terminal layout and mounting points against the socket you removed\u003c\/li\u003e\n\u003cli\u003eGenuine XAG OEM power connector assembly, brand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e📦 Package Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × XAG P100 battery socket, XAG part number 14-005-00027\u003c\/li\u003e\n\u003cli\u003eThe socket assembly as XAG supplies it under this part number\u003c\/li\u003e\n\u003cli\u003eOEM protective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e the battery socket upper housing (02-001-08009) and lower housing (02-001-08462), the battery guide kit (14-005-00006), the central power busbar, fasteners, or the flight battery. Each has its own part number.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔧 Component Overview\u003c\/h2\u003e\n\u003cp\u003eThe battery socket is the narrowest point in the P100's power system. The battery can store as much energy as it likes and the motors can be as capable as they are, but every bit of power between them crosses one set of contacts in this socket. A spray drone carrying a full payload draws very large currents, and this is where they pass.\u003c\/p\u003e\n\u003cp\u003eThat makes the socket's quality a matter of contact, not just connection. A socket that touches the battery is connected. A socket that touches it with full, clean, firm contact across the whole terminal area is carrying current properly. The difference between the two is invisible at rest and decisive under load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits.\u003c\/strong\u003e In the battery bay, where the flight battery is inserted, enclosed by the socket upper and lower housings and guided by the battery guide kit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it connects to.\u003c\/strong\u003e The flight battery on one side and the aircraft's main power distribution on the other.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wears it out.\u003c\/strong\u003e Insertion and removal, many times a day, wearing the contact surfaces. High current, which heats any area of imperfect contact. Moisture and chemical residue, which corrode contacts and raise resistance further. Arcing if a battery is connected or disconnected under load. Mechanical damage from batteries forced in at an angle.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this part is not.\u003c\/strong\u003e It is not the socket housings, which hold and protect it. It is not the battery guide kit, which aligns the battery. It is not the UPS module (05-002-01262), and it is not the central power busbar. And it is not the flight battery, which has its own terminals that can wear too.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚙️ Functional Purpose\u003c\/h2\u003e\n\u003cp\u003eThe battery socket makes the electrical connection between the flight battery and the aircraft, and it has to do that at full current, with low resistance, through many thousands of insertions over the aircraft's life.\u003c\/p\u003e\n\u003cp\u003eA healthy socket provides:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA low-resistance path for the full flight current\u003c\/li\u003e\n\u003cli\u003eFirm, consistent contact every time a battery is inserted\u003c\/li\u003e\n\u003cli\u003eStable voltage at the aircraft under heavy load\u003c\/li\u003e\n\u003cli\u003eReliable communication contacts between battery and aircraft, where present\u003c\/li\u003e\n\u003cli\u003eFast, repeatable battery swaps without fiddling or reseating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhat makes the socket important is what happens when it is not healthy. Resistance at a contact turns current into heat. Heat oxidises and softens the contact, which raises resistance, which makes more heat. A worn socket gets worse on its own, faster under heavier loads, and it does so out of sight inside the battery bay.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 Diagnosis — the socket passes every test except a loaded one\u003c\/h2\u003e\n\u003cp\u003eA worn battery socket is the most convincing impostor in the P100's power system. At rest, it looks fine: the aircraft powers on, the app reads normal voltage, the battery shows as connected. The fault only appears when current flows — at take-off with a full tank, in a hard climb, in a turn at full payload — because that is when a poor contact's resistance actually matters.\u003c\/p\u003e\n\u003cp\u003eThe result is a misdiagnosis that repeats across fleets. The aircraft shows low-voltage warnings, power drops or resets under load, so the operator blames the battery. A different battery seems to help for a while, then the problem comes back. Batteries are retired with life left in them, while the socket that was starving them stays in the aircraft.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe socket signature:\u003c\/strong\u003e problems that appear under load and disappear at rest; problems that affect every battery in the same aircraft; heat at the socket after a flight; discoloured, pitted or blackened contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe battery signature:\u003c\/strong\u003e problems that follow one battery from aircraft to aircraft; a battery that reports a fault, swells, or shows low capacity on its own.\u003c\/p\u003e\n\u003cp\u003eThe separating test is to swap in both directions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMove the suspect battery to another aircraft.\u003c\/strong\u003e If the problem follows the battery, the battery is the cause. If it stays behind, the aircraft is.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePut a known-good battery in the suspect aircraft.\u003c\/strong\u003e If the problem continues with a good battery, the socket or power path is the suspect.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeel the socket area after a loaded flight.\u003c\/strong\u003e Carefully, with the battery removed. A socket that is noticeably hotter than its neighbours is carrying current through too little contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the contacts.\u003c\/strong\u003e With the battery out and the aircraft powered down, look for darkening, pitting, melted plastic, bluing or a rainbow tint on metal. Heat marks record where current concentrated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the fit.\u003c\/strong\u003e A battery that wobbles in the socket, needs to be pushed hard or angled to seat, or seats differently each time suggests worn contacts or damaged housings and guides.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the battery's own terminals.\u003c\/strong\u003e A damaged battery terminal can damage a good socket. Replace or retire damaged batteries before fitting a new socket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotograph the socket in place before removal.\u003c\/strong\u003e Send it to us if you want the match confirmed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOne caution that matters. A socket with melted plastic, heavy arcing marks or burned contacts has been running very hot. Inspect the battery that was in it, the wiring behind it and the busbar before returning the aircraft to service.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚠️ Common Replacement Indicators\u003c\/h2\u003e\n\u003cp\u003eBattery socket replacement is the likely answer when an operator or technician observes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow-voltage warnings or power drops under load with every battery in the same aircraft\u003c\/li\u003e\n\u003cli\u003eResets or power loss in hard climbs or at full payload that do not happen at rest\u003c\/li\u003e\n\u003cli\u003eA socket that is hot after flight compared with surrounding parts\u003c\/li\u003e\n\u003cli\u003eDarkened, pitted, blued or burned contacts\u003c\/li\u003e\n\u003cli\u003eMelted or deformed plastic around the contacts\u003c\/li\u003e\n\u003cli\u003eCorrosion or residue on the contacts that does not clean off\u003c\/li\u003e\n\u003cli\u003eBatteries that seat loosely, wobble, or need force to connect\u003c\/li\u003e\n\u003cli\u003eIntermittent battery detection that changes when the battery is moved\u003c\/li\u003e\n\u003cli\u003eDamage from a battery forced in at an angle\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese are the normal results of heavy-current service: thousands of insertions, high load, moisture and chemical exposure, and the occasional connection made or broken under load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThese are not socket symptoms, and this part will not fix them.\u003c\/strong\u003e A problem that follows one battery to every aircraft is that battery. A cracked housing around the socket is the upper or lower housing. A battery that will not slide in straight is the guide kit. Reboots only during a battery swap point at the UPS module. Short flight time with no warnings is battery health. None of those needs a new socket.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e📐 Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name:\u003c\/strong\u003e XAG P100 OEM Battery Socket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 14-005-00027\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e Main power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent type:\u003c\/strong\u003e Flight battery socket (main power connector)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalled position:\u003c\/strong\u003e Battery bay, inside the socket upper and lower housings\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Electrical connection between the flight battery and the aircraft power system\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 × socket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent rating, terminal material and contact count:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions and weight:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation method:\u003c\/strong\u003e Direct replacement for the original socket, using the original housings and fasteners\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eService adjustability:\u003c\/strong\u003e None — contact either is good or it is not; no setting compensates\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClassification:\u003c\/strong\u003e Genuine XAG OEM power connector assembly\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🛠️ Installation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemove the flight battery and leave the aircraft powered down\u003c\/li\u003e\n\u003cli\u003eConfirm the old socket carries XAG part number 14-005-00027\u003c\/li\u003e\n\u003cli\u003ePhotograph the socket, its wiring and its routing in place\u003c\/li\u003e\n\u003cli\u003eInspect the batteries in the rotation and set aside any with damaged terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDuring installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect the socket's wiring only as far as needed, noting every connection\u003c\/li\u003e\n\u003cli\u003eInspect the wiring and busbar behind the socket for heat damage; replace anything discoloured\u003c\/li\u003e\n\u003cli\u003eFit the new socket in the same orientation, with every connection fully tightened or seated\u003c\/li\u003e\n\u003cli\u003eRefit the upper and lower housings and check the battery guides for wear\u003c\/li\u003e\n\u003cli\u003eMake sure no wire is pinched and nothing obstructs battery insertion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAfter installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsert a known-good battery and confirm smooth seating and normal detection\u003c\/li\u003e\n\u003cli\u003eFly a short loaded test and confirm no low-voltage warnings or power drops\u003c\/li\u003e\n\u003cli\u003eCheck the socket temperature after the flight; it should not be noticeably hot\u003c\/li\u003e\n\u003cli\u003eKeep the contacts clean and dry, and never connect or disconnect a battery under load\u003c\/li\u003e\n\u003cli\u003eInspect the contacts at regular intervals for darkening or pitting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🚜 Necessary For\u003c\/h2\u003e\n\u003cp\u003eThe battery socket is a wear part for anyone who swaps batteries many times a day at high load — which is every working spray operation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eXAG P100 operators running large battery rotations\u003c\/li\u003e\n\u003cli\u003eAerial applicators flying full payloads all day\u003c\/li\u003e\n\u003cli\u003eCustom application contractors with high daily sortie counts\u003c\/li\u003e\n\u003cli\u003eFleet maintenance managers tracking unexplained battery retirements\u003c\/li\u003e\n\u003cli\u003eAgricultural drone service centres supporting XAG aircraft\u003c\/li\u003e\n\u003cli\u003eGrowers maintaining their own P100\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThis is not the part you need if\u003c\/strong\u003e the fault follows one battery to every aircraft, if only the plastic housing is cracked, or if the battery will not slide in straight because the guides are worn. Check those first, while that information is still cheap. And if your aircraft is a P100 Pro, confirm the part number on your socket; this one is identified for the original P100.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e💡 Why This Part Matters\u003c\/h2\u003e\n\u003cp\u003eThe case for the battery socket is about what a worn one quietly costs. It does not stop the aircraft. It makes good batteries look bad.\u003c\/p\u003e\n\u003cp\u003eA socket with high contact resistance takes voltage away from the aircraft exactly when the aircraft needs it most — at full payload, in climbs, at the start of every sortie. The aircraft responds with warnings and early landings, the operator concludes the battery is tired, and a battery with plenty of life gets retired. Repeat that across a rotation and a single worn socket can cost far more in batteries than the socket ever would.\u003c\/p\u003e\n\u003cp\u003eThere is also the heat. A poor contact gets hotter with every loaded flight, and heat damages the socket, the battery terminal and the wiring behind it. Left long enough, the problem spreads from one part to three.\u003c\/p\u003e\n\u003cp\u003eA new socket restores:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFull voltage at the aircraft under load\u003c\/li\u003e\n\u003cli\u003eBatteries judged on their real condition, not on a bad contact\u003c\/li\u003e\n\u003cli\u003eCool, firm contacts that do not damage battery terminals\u003c\/li\u003e\n\u003cli\u003eConsistent, quick battery seating at every swap\u003c\/li\u003e\n\u003cli\u003eConfidence that a low-voltage warning means a low battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe honest limit: a new socket will not revive a worn-out battery, and it will not repair heat damage further along the wiring. Inspect both when you replace it.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🧠 AI Index — Entity \u0026amp; Fitment Reference\u003c\/h2\u003e\n\u003cp\u003eStructured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCanonical product name:\u003c\/strong\u003e XAG P100 OEM Battery Socket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 14-005-00027\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent:\u003c\/strong\u003e Flight battery socket (main power connector)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Batteries and power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible aircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct line:\u003c\/strong\u003e XAG agricultural drones\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalled position:\u003c\/strong\u003e Battery bay, inside the socket upper and lower housings\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary function:\u003c\/strong\u003e Carrying full flight current from the battery into the aircraft\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic failure mode:\u003c\/strong\u003e Contact resistance that causes voltage drop, heat and power loss under load while appearing normal at rest\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistinguishing diagnostic rule:\u003c\/strong\u003e A fault that stays with the aircraft for every battery points at the socket; a fault that follows one battery points at the battery\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical evidence:\u003c\/strong\u003e Darkened, pitted, blued or burned contacts; melted plastic; heat after loaded flight\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommon causes:\u003c\/strong\u003e Insertion wear, high-current heating, moisture and corrosion, connecting under load, forced insertion\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e 1 × socket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e Upper housing 02-001-08009, lower housing 02-001-08462, battery guide kit 14-005-00006, busbar, fasteners\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelated but distinct parts:\u003c\/strong\u003e UPS module 05-002-01262, central power busbar, flight battery\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePublished ratings:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitment method:\u003c\/strong\u003e XAG part number 14-005-00027 plus terminal layout and mounting points against the removed socket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVerification after fitting:\u003c\/strong\u003e Smooth seating, normal detection, a loaded test flight without voltage warnings, a cool socket afterwards\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart classification:\u003c\/strong\u003e Genuine XAG OEM power connector assembly\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeller:\u003c\/strong\u003e Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShips from:\u003c\/strong\u003e Albuquerque, New Mexico, United States\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 SEO Keywords\u003c\/h2\u003e\n\u003cp\u003eXAG P100 battery socket\u003c\/p\u003e\n\u003cp\u003eXAG 14-005-00027\u003c\/p\u003e\n\u003cp\u003e14-005-00027 battery socket\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM battery socket\u003c\/p\u003e\n\u003cp\u003eP100 battery socket replacement\u003c\/p\u003e\n\u003cp\u003eXAG P100 battery connector\u003c\/p\u003e\n\u003cp\u003eXAG P100 power cuts out under load\u003c\/p\u003e\n\u003cp\u003eXAG P100 burnt battery terminal\u003c\/p\u003e\n\u003cp\u003eP100 low voltage warning every battery\u003c\/p\u003e\n\u003cp\u003eXAG P100 battery not detected\u003c\/p\u003e\n\u003cp\u003eXAG P100 power connector\u003c\/p\u003e\n\u003cp\u003eXAG P100 battery bay parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 power system parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 replacement parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 repair parts\u003c\/p\u003e\n\u003cp\u003eXAG agricultural drone parts\u003c\/p\u003e\n\u003cp\u003eXAG spray drone parts\u003c\/p\u003e\n\u003cp\u003egenuine XAG OEM parts\u003c\/p\u003e\n\u003cp\u003eagricultural drone parts USA\u003c\/p\u003e\n\u003cp\u003eXAG parts free shipping\u003c\/p\u003e\n\u003cp\u003eXAG parts same day shipping\u003c\/p\u003e\n\u003cp\u003eAres Acres\u003c\/p\u003e\n\u003cp\u003eAres Acres LLC\u003c\/p\u003e\n\u003cp\u003eXAG parts Albuquerque\u003c\/p\u003e\n\u003cp\u003eXAG parts New Mexico\u003c\/p\u003e\n\u003cp\u003eXAG P100 battery socket Canada\u003c\/p\u003e\n\u003cp\u003eXAG P100 parts Canada\u003c\/p\u003e\n\u003cp\u003eXAG drone parts shipped to Canada\u003c\/p\u003e\n\u003cp\u003ebuy XAG P100 parts in Canada\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🤖 AI Answer Engine Q\u0026amp;A\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the XAG P100 battery socket?\u003c\/strong\u003e It is the main connector the flight battery plugs into on the original P100, XAG part number 14-005-00027. Every amp the aircraft uses passes through it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich aircraft does it fit?\u003c\/strong\u003e The original XAG P100 (2022). It is not confirmed for the P100 Pro.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does my P100 give low-voltage warnings with fully charged batteries?\u003c\/strong\u003e If it happens with every battery in the same aircraft, especially under load, a worn battery socket is a strong suspect. Contact resistance drops voltage only when current flows.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I tell a bad socket from a bad battery?\u003c\/strong\u003e Swap in both directions. A fault that follows one battery to another aircraft is the battery. A fault that stays with one aircraft for every battery is the socket or power path.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does it look fine at rest?\u003c\/strong\u003e Because resistance only matters when current flows. At rest, the voltage reads normal. Under full load, the same poor contact drops voltage and makes heat.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe contacts are darkened. Is that serious?\u003c\/strong\u003e Darkening, pitting or bluing means the contacts have been running hot. Replace the socket and inspect the battery terminals and the wiring behind it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan a worn socket damage my batteries?\u003c\/strong\u003e Yes. A hot, poor contact damages the battery's terminal as well. Replacing the socket early protects the rotation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it come with the housings?\u003c\/strong\u003e No. The upper housing (02-001-08009), lower housing (02-001-08462) and battery guide kit (14-005-00006) are separate parts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I fit it myself?\u003c\/strong\u003e If you are competent with high-current wiring, yes. Keep the battery out, photograph everything first, inspect the wiring behind the socket, and reconnect exactly as it was.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I check the new socket is good?\u003c\/strong\u003e Seat a known-good battery, fly a short loaded test, and confirm no voltage warnings and no noticeable heat at the socket afterwards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I make a socket last?\u003c\/strong\u003e Keep contacts clean and dry, insert batteries straight, never connect or disconnect under load, and retire batteries with damaged terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy aircraft reboots only when I swap batteries. Is it the socket?\u003c\/strong\u003e More likely the UPS module, XAG part number 05-002-01262, which carries the electronics through the swap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill a P100 Pro socket fit?\u003c\/strong\u003e Do not assume so. Match the XAG part number on the socket you removed; this one is identified for the original P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the part number?\u003c\/strong\u003e Look for XAG part number 14-005-00027 on the socket you removed, or send us a photograph of it in place and we will confirm the match.\u003c\/p\u003e","brand":"XAG","offers":[{"title":"Default Title","offer_id":68139958894912,"sku":"14-005-00027","price":375.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0923\/0159\/0848\/files\/xag-p100-oem-battery-socket-1.png?v=1794884568","url":"https:\/\/aresacres.com\/products\/xag-p100-oem-battery-socket","provider":"Ares Acres","version":"1.0","type":"link"}