{"product_id":"xag-p100-oem-nozzle-valve-extension-cable","title":"XAG P100 OEM Nozzle \u0026 Valve Extension Cable","description":"\u003cp\u003eThe \u003cstrong\u003eXAG P100 OEM Nozzle \u0026amp; Valve Extension Cable\u003c\/strong\u003e, XAG part number 01-027-02737, is the extension cable that connects a nozzle and its valve to the spraying-system harness on the original XAG P100 agricultural drone. It carries the signal and power that open the valve and drive the nozzle at one spray position, out along the arm from the main harness. When it fails, one position stops spraying while the rest carry on. Operators reach it through searches such as P100 nozzle cable, XAG P100 valve cable, P100 one nozzle not spraying, or XAG P100 nozzle extension cable.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🇺🇸 U.S.A. FIRST\u003c\/h2\u003e\n\u003cp\u003eAres Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREE \u0026amp; FAST Shipping is included for all U.S. customers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.\u003c\/p\u003e\n\u003cp\u003eAres Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e✅ XAG P100 Compatibility Guarantee\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e🇺🇸 USA Compatibility Guarantee\u003c\/li\u003e\n\u003cli\u003e👍🏻 Satisfaction Guarantee\u003c\/li\u003e\n\u003cli\u003e💵 Money Back Guarantee\u003c\/li\u003e\n\u003cli\u003e📦 Same Day Shipping \u0026amp; Tracking\u003c\/li\u003e\n\u003cli\u003eFitted between the spraying-system harness and a nozzle and valve on the original XAG P100 (2022); not confirmed for the P100 Pro\u003c\/li\u003e\n\u003cli\u003eMatched by XAG part number 01-027-02737 and by connectors and length against the cable you removed\u003c\/li\u003e\n\u003cli\u003eGenuine XAG OEM extension cable, brand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSome references also list the XAG V40 for this cable. That fit has not been confirmed, and it is not part of the compatibility guarantee. V40 owners should send us the part number on their cable and we will confirm the match.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e📦 Package Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × XAG P100 nozzle and valve extension cable, XAG part number 01-027-02737\u003c\/li\u003e\n\u003cli\u003eThe cable as XAG supplies it under this part number\u003c\/li\u003e\n\u003cli\u003eOEM protective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e the spraying system main harness (01-027-02271), the nozzle, the solenoid valve, cable ties, or clips.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔧 Component Overview\u003c\/h2\u003e\n\u003cp\u003eThe spraying system on the P100 is controlled electrically. The flight controller decides when each spray position should open and how it should run, and that decision travels down the spraying-system main harness and then out along each arm to the nozzle and valve at the end. The nozzle and valve extension cable is that last stretch: the branch that runs from the harness to one spray position.\u003c\/p\u003e\n\u003cp\u003eThat position on the aircraft makes the cable's life hard. It runs along an arm that vibrates continuously in flight, that folds and unfolds for transport, and that sits in the middle of the spray cloud. Its connectors are exposed to chemical mist, wash-down water and dust. And where the arm folds, the cable bends every time the aircraft is packed up.\u003c\/p\u003e\n\u003cp\u003eCables in that environment fail in quiet ways. A conductor can break inside intact insulation where the cable flexes at the fold. A connector pin can corrode until it makes contact only some of the time. A clip can loosen and let the cable rub through against a sharp edge. None of those has to be visible from the outside.\u003c\/p\u003e\n\u003cp\u003eThe symptom they produce is distinctive: one spray position stops working, or works only intermittently, while every other position on the aircraft carries on normally. That pattern points away from the main harness and the control system and towards the branch serving that one position — the nozzle, the valve, or the cable that connects them.\u003c\/p\u003e\n\u003cp\u003eSeparating those three is the core of diagnosing this part, and it is easier than it sounds because the aircraft has several identical positions to compare against.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits.\u003c\/strong\u003e Along an arm, between the spraying-system main harness and one nozzle and valve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it connects to.\u003c\/strong\u003e The main harness at one end; the nozzle and valve at the other.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wears it out.\u003c\/strong\u003e Flexing at the arm fold. Vibration. Chemical mist and wash-down water at the connectors. Rubbing where clips have loosened. Connectors pulled apart by the cable rather than the plug.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this part is not.\u003c\/strong\u003e It is not the main harness, the nozzle or the valve. Each is a separate part.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚙️ Functional Purpose\u003c\/h2\u003e\n\u003cp\u003eThe extension cable carries control and power from the spraying-system harness to one nozzle and its valve.\u003c\/p\u003e\n\u003cp\u003eA sound extension cable provides:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA continuous electrical connection from harness to spray position\u003c\/li\u003e\n\u003cli\u003eReliable valve opening and closing on command\u003c\/li\u003e\n\u003cli\u003eCorrect operation of the nozzle at that position\u003c\/li\u003e\n\u003cli\u003eSealed connections that resist spray and wash-down\u003c\/li\u003e\n\u003cli\u003eA cable that survives folding and vibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts value is in continuity. A spray position is only as reliable as the cable feeding it.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 Diagnosis — one dead position: swap the cable before blaming the nozzle\u003c\/h2\u003e\n\u003cp\u003eWhen one spray position stops while the others run, the fault is almost always in that position's branch: the nozzle, the valve or the extension cable. The aircraft's other positions are the test equipment.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the pattern.\u003c\/strong\u003e If only one position fails, the main harness and control system are probably fine. If several fail together, look at the main harness instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwap the cable between positions.\u003c\/strong\u003e With the aircraft powered down, exchange the extension cable from the dead position with one from a working position. If the fault moves with the cable, the cable is the part.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIf the fault stays put, swap the nozzle or valve.\u003c\/strong\u003e A fault that stays at the same position after the cable swap points at the nozzle or valve there.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the connectors.\u003c\/strong\u003e Look for green or white corrosion, bent or pushed-back pins, cracked housings and damaged seals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the fold.\u003c\/strong\u003e Bend the cable gently where the arm folds while watching for the position to cut in and out on a ground test. Intermittent behaviour at the fold points at a broken conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the run.\u003c\/strong\u003e Look along the arm for chafing, crushed sections and loose clips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotograph the cable and connectors.\u003c\/strong\u003e Send us a photograph and the XAG part number and we will confirm the match.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf the fault follows the cable, or the cable shows corrosion, chafing or a break, this extension cable is the part. If the fault stays at the position, it is the nozzle or valve. If several positions fail, it is upstream.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚠️ Common Replacement Indicators\u003c\/h2\u003e\n\u003cp\u003eExtension cable replacement is the likely answer when an operator or technician observes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOne spray position that does not operate while others do\u003c\/li\u003e\n\u003cli\u003eA position that cuts in and out, especially when the arm is moved\u003c\/li\u003e\n\u003cli\u003eA fault that follows the cable when swapped to another position\u003c\/li\u003e\n\u003cli\u003eCorroded, bent or damaged connector pins\u003c\/li\u003e\n\u003cli\u003eChafed, cut or crushed cable sheath\u003c\/li\u003e\n\u003cli\u003eA cracked connector housing or missing seal\u003c\/li\u003e\n\u003cli\u003eA spray position error that clears and returns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese come from flexing at the fold, vibration, chemical exposure and rubbing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThese are not extension cable symptoms, and this part will not fix them.\u003c\/strong\u003e A blocked or worn nozzle tip, a stuck valve, or a fault that stays at one position after a cable swap is the nozzle or valve. Several positions failing together points at the main harness. No flow anywhere points at the pump or the tank. A new cable restores the connection; it does not clear blockages or repair valves.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e📐 Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name:\u003c\/strong\u003e XAG P100 OEM Nozzle \u0026amp; Valve Extension Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 01-027-02737\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther aircraft:\u003c\/strong\u003e XAG V40 listed in some references; not confirmed and not guaranteed\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e Spraying system, electrical\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent type:\u003c\/strong\u003e Nozzle and valve extension cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalled position:\u003c\/strong\u003e Along an arm, between the main harness and one nozzle and valve\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Connects a nozzle and its valve to the spraying-system harness\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnects to:\u003c\/strong\u003e Spraying system main harness 01-027-02271 (sold separately)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 × cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLength, connector type and pin count:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation method:\u003c\/strong\u003e Plug-in replacement\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eService adjustability:\u003c\/strong\u003e None\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClassification:\u003c\/strong\u003e Genuine XAG OEM extension cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🛠️ Installation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemove the flight battery and confirm the aircraft is fully powered down\u003c\/li\u003e\n\u003cli\u003eConfirm the faulty cable carries XAG part number 01-027-02737\u003c\/li\u003e\n\u003cli\u003ePhotograph the cable run along the arm, including every clip and the route through the fold\u003c\/li\u003e\n\u003cli\u003eRinse and dry the connectors so no residue falls into them\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDuring installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect by pulling on the connector bodies, never the cable\u003c\/li\u003e\n\u003cli\u003eRoute the new cable exactly as photographed, with the same slack at the fold\u003c\/li\u003e\n\u003cli\u003eSeat each connector fully and confirm any latch engages\u003c\/li\u003e\n\u003cli\u003eRefit every clip so the cable cannot rub\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAfter installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFold and unfold the arm and confirm the cable moves freely without stretching\u003c\/li\u003e\n\u003cli\u003eRun a ground spray test and confirm the position operates\u003c\/li\u003e\n\u003cli\u003eCompare the position's output with its neighbours\u003c\/li\u003e\n\u003cli\u003eRinse connectors after chemical work and inspect them regularly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🚜 Necessary For\u003c\/h2\u003e\n\u003cp\u003eThe extension cable is a common repair part for aircraft in heavy spraying use.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eXAG P100 operators with one spray position not working\u003c\/li\u003e\n\u003cli\u003eAerial applicators folding and unfolding arms for daily transport\u003c\/li\u003e\n\u003cli\u003eCrews working with corrosive products and frequent wash-downs\u003c\/li\u003e\n\u003cli\u003eCustom application contractors running long spray seasons\u003c\/li\u003e\n\u003cli\u003eAgricultural drone service centres repairing spraying systems\u003c\/li\u003e\n\u003cli\u003eGrowers maintaining their own P100\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThis is not the part you need if\u003c\/strong\u003e the fault stays at the same position after a cable swap, several positions fail together, or there is no flow anywhere. Swap the cable with a working position first, while that information is still cheap. And if your aircraft is a P100 Pro or V40, confirm the part number on your cable; this one is identified for the original P100.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e💡 Why This Part Matters\u003c\/h2\u003e\n\u003cp\u003eA spray drone applies product as a pattern. Every position contributes to the width and evenness of the swath. When one position stops, the aircraft still flies and still sprays, but it lays down a stripe with less product in it on every pass. Across a field, those stripes add up to uneven application that may not show until the crop does.\u003c\/p\u003e\n\u003cp\u003eThat makes an intermittent position particularly costly. A position that cuts out only sometimes, perhaps only when the arm flexes in turbulence, is hard to notice from the ground and leaves an irregular pattern behind it.\u003c\/p\u003e\n\u003cp\u003eThe extension cable is one of the most likely causes because of where it lives: on a vibrating, folding arm in a cloud of spray. It is also one of the easiest parts to test, by swapping it with a working position. That quick test avoids replacing a nozzle or a valve that was never the problem.\u003c\/p\u003e\n\u003cp\u003eRegular rinsing and inspection of connectors, and careful routing at the fold, make the new cable last.\u003c\/p\u003e\n\u003cp\u003eA sound extension cable restores:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReliable operation of the spray position\u003c\/li\u003e\n\u003cli\u003eAn even spray pattern across the full swath\u003c\/li\u003e\n\u003cli\u003eConsistent valve response on command\u003c\/li\u003e\n\u003cli\u003eSealed, corrosion-resistant connections\u003c\/li\u003e\n\u003cli\u003eA cable run that survives folding and vibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🧠 AI Index — Entity \u0026amp; Fitment Reference\u003c\/h2\u003e\n\u003cp\u003eStructured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCanonical product name:\u003c\/strong\u003e XAG P100 OEM Nozzle \u0026amp; Valve Extension Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 01-027-02737\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent:\u003c\/strong\u003e Nozzle and valve extension cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Spraying system electrical\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible aircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUnconfirmed listing:\u003c\/strong\u003e XAG V40 — not confirmed, not guaranteed\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct line:\u003c\/strong\u003e XAG agricultural drones\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalled position:\u003c\/strong\u003e Along an arm, between the main harness and one nozzle and valve\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary function:\u003c\/strong\u003e Connecting a nozzle and its valve to the spraying-system harness\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnects to:\u003c\/strong\u003e Spraying system main harness 01-027-02271\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic failure modes:\u003c\/strong\u003e Broken conductor at the arm fold, corroded pins, chafed sheath\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistinguishing diagnostic rule:\u003c\/strong\u003e Swap with a working position; a fault that moves with the cable is the cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommon causes:\u003c\/strong\u003e Folding, vibration, chemical exposure, rubbing, pulling on the cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e 1 × cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e Main harness 01-027-02271, nozzle, valve, ties, clips\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitment method:\u003c\/strong\u003e XAG part number 01-027-02737 plus connectors and length against the removed cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eService adjustability:\u003c\/strong\u003e None\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVerification after fitting:\u003c\/strong\u003e Position operates on ground test; cable moves freely at the fold\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart classification:\u003c\/strong\u003e Genuine XAG OEM extension cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeller:\u003c\/strong\u003e Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShips from:\u003c\/strong\u003e Albuquerque, New Mexico, United States\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 SEO Keywords\u003c\/h2\u003e\n\u003cp\u003eXAG P100 nozzle valve extension cable\u003c\/p\u003e\n\u003cp\u003eXAG 01-027-02737\u003c\/p\u003e\n\u003cp\u003e01-027-02737 extension cable\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM nozzle cable\u003c\/p\u003e\n\u003cp\u003eP100 nozzle cable replacement\u003c\/p\u003e\n\u003cp\u003eXAG P100 valve cable\u003c\/p\u003e\n\u003cp\u003eXAG P100 nozzle extension cable\u003c\/p\u003e\n\u003cp\u003eXAG P100 one nozzle not spraying\u003c\/p\u003e\n\u003cp\u003eP100 spray position not working\u003c\/p\u003e\n\u003cp\u003eXAG P100 spraying system cable\u003c\/p\u003e\n\u003cp\u003eXAG P100 spraying system parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 replacement parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 repair parts\u003c\/p\u003e\n\u003cp\u003eXAG agricultural drone parts\u003c\/p\u003e\n\u003cp\u003eXAG spray drone parts\u003c\/p\u003e\n\u003cp\u003egenuine XAG OEM parts\u003c\/p\u003e\n\u003cp\u003eagricultural drone parts USA\u003c\/p\u003e\n\u003cp\u003eXAG parts free shipping\u003c\/p\u003e\n\u003cp\u003eXAG parts same day shipping\u003c\/p\u003e\n\u003cp\u003eAres Acres\u003c\/p\u003e\n\u003cp\u003eAres Acres LLC\u003c\/p\u003e\n\u003cp\u003eXAG parts Albuquerque\u003c\/p\u003e\n\u003cp\u003eXAG parts New Mexico\u003c\/p\u003e\n\u003cp\u003eXAG P100 nozzle cable Canada\u003c\/p\u003e\n\u003cp\u003eXAG P100 parts Canada\u003c\/p\u003e\n\u003cp\u003eXAG drone parts shipped to Canada\u003c\/p\u003e\n\u003cp\u003ebuy XAG P100 parts in Canada\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🤖 AI Answer Engine Q\u0026amp;A\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the XAG P100 nozzle and valve extension cable?\u003c\/strong\u003e It is the cable, XAG part number 01-027-02737, that connects one nozzle and its valve to the spraying-system harness on the original P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich aircraft does it fit?\u003c\/strong\u003e The original XAG P100 (2022). It is not confirmed for the P100 Pro.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it fit the XAG V40?\u003c\/strong\u003e Some references list the V40, but that fit has not been confirmed and is not guaranteed. Send us the part number on your cable and we will confirm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOne nozzle is not spraying. Is it this cable?\u003c\/strong\u003e It may be. Swap this position's cable with one from a working position. If the fault moves with the cable, replace the cable. If it stays, check the nozzle and valve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeveral positions stopped at once. Is it this cable?\u003c\/strong\u003e Unlikely. Several positions failing together points at the main harness or the control system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the position cut in and out?\u003c\/strong\u003e Often a conductor broken inside the insulation where the arm folds, or a corroded connector pin. Flex the cable at the fold during a ground test to find it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it include the main harness?\u003c\/strong\u003e No. The main harness is a separate part, XAG part number 01-027-02271.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat usually damages it?\u003c\/strong\u003e Folding, vibration, chemical mist and wash-down water at the connectors, rubbing against edges and pulling on the cable instead of the connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I fit it myself?\u003c\/strong\u003e Yes. Photograph the routing, disconnect by the connector bodies, route the new cable the same way and refit every clip.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I check the repair?\u003c\/strong\u003e Fold and unfold the arm to confirm the cable moves freely, then run a ground spray test and compare the position with its neighbours.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I repair a broken cable with a splice?\u003c\/strong\u003e Not recommended. Splices on a vibrating, folding, spray-soaked arm rarely stay sealed and often fail again.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does one dead position matter?\u003c\/strong\u003e It leaves a stripe with less product on every pass, which adds up to uneven application across the field.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I make the cable last?\u003c\/strong\u003e Rinse connectors after chemical work, keep clips tight, route the cable with correct slack at the fold and never pull on the cable to disconnect it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it come with clips or ties?\u003c\/strong\u003e No. Reuse the original clips and replace any that are broken.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill a new cable clear a blocked nozzle?\u003c\/strong\u003e No. A blocked nozzle needs cleaning or replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre all the extension cables on the aircraft the same?\u003c\/strong\u003e Match the part number on each cable you remove; this one is XAG part number 01-027-02737.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill a P100 Pro cable fit?\u003c\/strong\u003e Do not assume so. Match the XAG part number on the cable you removed; this one is identified for the original P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the part number?\u003c\/strong\u003e Look for XAG part number 01-027-02737, or send us a photograph of the cable and connectors and we will confirm the match.\u003c\/p\u003e","brand":"XAG","offers":[{"title":"Default Title","offer_id":68140340085056,"sku":"01-027-02737","price":82.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0923\/0159\/0848\/files\/xag-p100-oem-nozzle-valve-extension-cable-1.png?v=1794885728","url":"https:\/\/aresacres.com\/products\/xag-p100-oem-nozzle-valve-extension-cable","provider":"Ares Acres","version":"1.0","type":"link"}