{"product_id":"xag-p100-oem-peristaltic-pump-type-b","title":"XAG P100 OEM Peristaltic Pump (Type B)","description":"\u003cp\u003eThe \u003cstrong\u003eXAG P100 OEM Peristaltic Pump (Type B)\u003c\/strong\u003e, XAG part number 05-002-01384, is a Type B peristaltic spray pump for the original XAG P100 agricultural drone. It draws spray liquid from the tank and pushes it to the nozzles by squeezing a flexible tube with rotating rollers, so the liquid never touches the pump's moving parts. Operators reach it through searches such as P100 peristaltic pump, XAG P100 pump Type B, P100 low flow, or XAG P100 pump not working.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🇺🇸 U.S.A. FIRST\u003c\/h2\u003e\n\u003cp\u003eAres Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREE \u0026amp; FAST Shipping is included for all U.S. customers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.\u003c\/p\u003e\n\u003cp\u003eAres Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e✅ XAG P100 Compatibility Guarantee\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e🇺🇸 USA Compatibility Guarantee\u003c\/li\u003e\n\u003cli\u003e👍🏻 Satisfaction Guarantee\u003c\/li\u003e\n\u003cli\u003e💵 Money Back Guarantee\u003c\/li\u003e\n\u003cli\u003e📦 Same Day Shipping \u0026amp; Tracking\u003c\/li\u003e\n\u003cli\u003eFitted in the spraying system of the original XAG P100 (2022); not confirmed for the P100 Pro\u003c\/li\u003e\n\u003cli\u003eMatched by XAG part number 05-002-01384 and by pump type (Type B), ports and mounting against the pump you removed\u003c\/li\u003e\n\u003cli\u003eGenuine XAG OEM peristaltic pump, brand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e📦 Package Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × XAG P100 peristaltic pump, Type B, XAG part number 05-002-01384\u003c\/li\u003e\n\u003cli\u003eThe pump assembly as XAG supplies it under this part number\u003c\/li\u003e\n\u003cli\u003eOEM protective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e the Type A pump (05-002-01383), the peristaltic pump tube kit (14-004-00015), the pump bracket (02-001-08313), the L-type tube fitting for the pump (02-001-08036), liquid tubes or fasteners.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔧 Component Overview\u003c\/h2\u003e\n\u003cp\u003eA peristaltic pump moves liquid the way a hand squeezes toothpaste along a tube. A flexible tube runs around a curved track, and rollers on a rotating head press the tube closed and roll along it. Each roller pushes a pocket of liquid ahead of it, and the tube springs back open behind, drawing the next pocket in. Faster rotation, more flow.\u003c\/p\u003e\n\u003cp\u003eThe design suits agricultural chemicals well. The liquid only ever touches the inside of the tube, so the motor, rollers and bearings never meet the product. Flow is closely tied to rotation speed, which makes the rate predictable and controllable. And the closed tube acts as its own seal when the pump stops.\u003c\/p\u003e\n\u003cp\u003eIt also means the pump has two very different kinds of part inside it. The drive — motor, gearing, roller head — is built to last. The tube is a consumable. It is squeezed flat and released many thousands of times every flight, and it is designed to be replaced.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits.\u003c\/strong\u003e In the P100 spraying system, on the pump bracket, between the tank outlet and the solenoid valves and nozzles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it connects to.\u003c\/strong\u003e The tank feed on the inlet side, the nozzle lines on the outlet side, and the aircraft's power and control for its drive.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eType A and Type B.\u003c\/strong\u003e XAG lists two peristaltic pump types for the P100 under different part numbers: Type A, 05-002-01383, and Type B, 05-002-01384. They are not interchangeable by assumption. Match the type and part number on the pump you are replacing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wears it out.\u003c\/strong\u003e Tube fatigue above all. Then running dry, which heats the tube and wears the rollers. Chemical attack on the tube. Abrasive suspended solids. Moisture reaching the drive. Electrical faults in the motor.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚙️ Functional Purpose\u003c\/h2\u003e\n\u003cp\u003eThe pump delivers spray liquid from tank to nozzles at the rate the aircraft commands, so the planned application rate becomes the actual application rate.\u003c\/p\u003e\n\u003cp\u003eA healthy pump provides:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlow proportional to the commanded rate\u003c\/li\u003e\n\u003cli\u003eSteady pressure and delivery to the nozzle lines\u003c\/li\u003e\n\u003cli\u003eSeparation of chemical from the pump's moving parts\u003c\/li\u003e\n\u003cli\u003eSelf-priming from the tank outlet\u003c\/li\u003e\n\u003cli\u003eA positive shut-off when it stops\u003c\/li\u003e\n\u003cli\u003ePredictable output that calibration can rely on\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe pump's output is only as good as its tube. A worn or softened tube does not seal fully under the rollers, so some liquid slips back on every turn. The pump still runs at the commanded speed; it simply moves less liquid than it should. That is the mechanism behind almost every “weak pump” complaint.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 Diagnosis — the tube wears out long before the pump does\u003c\/h2\u003e\n\u003cp\u003eWhen a P100 under-applies, the pump is the obvious suspect. In a peristaltic pump, though, the motor and roller head rarely fail first. The tube does. And a tube is a fraction of a pump. Replacing a pump to fix a worn tube is buying the whole pump to get one consumable.\u003c\/p\u003e\n\u003cp\u003eSo the diagnosis separates the drive from the tube.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the pump turning?\u003c\/strong\u003e Run the spraying system on water. If the pump head does not turn at all, or turns only intermittently, the drive, its power or its control is the suspect — this pump, its connector or the harness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs it turning but delivering little?\u003c\/strong\u003e If the head turns at normal speed but flow is low, look at the tube before the pump. A flattened, cracked, stiff or swollen tube is the usual cause.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck upstream first.\u003c\/strong\u003e A blocked tank inlet filter, a kinked feed tube or an air leak at the pump's inlet fitting starve the pump and look like low output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck downstream.\u003c\/strong\u003e Blocked nozzles or a valve that does not open make a good pump appear weak.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListen and feel.\u003c\/strong\u003e Grinding, knocking or a hot drive point at the rollers, bearings or gearbox inside the pump. A smooth pump with low output points at the tube.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLook for leaks.\u003c\/strong\u003e Liquid inside the pump housing means a ruptured tube. Replace the tube and clean out the housing before the chemical reaches the drive.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotograph the pump and its connections in place.\u003c\/strong\u003e Send us the photograph if you want the type and part number confirmed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf the drive turns smoothly and the problem is low output, fit the peristaltic pump tube kit, XAG part number 14-004-00015, and test again. Replace the pump when the drive itself has failed.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚠️ Common Replacement Indicators\u003c\/h2\u003e\n\u003cp\u003ePump replacement is the likely answer when an operator or technician observes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe pump head does not turn, with power and control confirmed at the pump\u003c\/li\u003e\n\u003cli\u003eIntermittent running that is not fixed by reseating the connector\u003c\/li\u003e\n\u003cli\u003eGrinding, knocking or rough rotation from the drive\u003c\/li\u003e\n\u003cli\u003eA drive that runs hot or smells burned\u003c\/li\u003e\n\u003cli\u003eLow output that remains after a new tube kit and clear filters, lines and nozzles\u003c\/li\u003e\n\u003cli\u003eChemical or water damage to the drive after a tube rupture\u003c\/li\u003e\n\u003cli\u003eCracked pump housing or broken roller head\u003c\/li\u003e\n\u003cli\u003ePump errors reported in the app\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThose failures come from running dry, chemical intrusion after tube rupture, heat, moisture reaching the drive, and age.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThese are not pump symptoms, and this part will not fix them.\u003c\/strong\u003e Low flow with a smoothly turning head is usually the tube — the tube kit, 14-004-00015. A blocked fill is the inlet filter. One nozzle not spraying is that nozzle, its line or its valve. Wrong level readings are the level detector. And a Type A position needs the Type A pump, 05-002-01383. None of those is this part.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e📐 Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name:\u003c\/strong\u003e XAG P100 OEM Peristaltic Pump (Type B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 05-002-01384\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e Spraying system\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent type:\u003c\/strong\u003e Peristaltic spray pump\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePump type:\u003c\/strong\u003e Type B (Type A is 05-002-01383)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalled position:\u003c\/strong\u003e On the pump bracket between the tank outlet and the nozzle lines\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Delivers spray liquid at the commanded rate\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 × pump\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlow rate, pressure and power ratings:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions and weight:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConsumable inside:\u003c\/strong\u003e Peristaltic tube, replaceable with tube kit 14-004-00015\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation method:\u003c\/strong\u003e Direct replacement on the existing pump bracket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eService adjustability:\u003c\/strong\u003e Tube is serviceable; the drive is replaced as an assembly\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClassification:\u003c\/strong\u003e Genuine XAG OEM peristaltic pump\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🛠️ Installation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEmpty and rinse the spraying system with clean water, wearing chemical-resistant gloves\u003c\/li\u003e\n\u003cli\u003eRemove the flight battery and power the aircraft down\u003c\/li\u003e\n\u003cli\u003eConfirm the old pump is Type B, XAG part number 05-002-01384\u003c\/li\u003e\n\u003cli\u003ePhotograph the pump, its inlet and outlet tubes and its connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDuring installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect the tubes and catch any residual liquid\u003c\/li\u003e\n\u003cli\u003eInspect the L-type fitting and tubes for cracks; replace any that are damaged\u003c\/li\u003e\n\u003cli\u003eMount the new pump on the bracket in the same orientation as the original\u003c\/li\u003e\n\u003cli\u003eReconnect inlet and outlet the same way round; a reversed pump moves liquid backwards\u003c\/li\u003e\n\u003cli\u003eSeat the electrical connector fully and secure the cable away from moving parts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAfter installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFill with clean water and run the spraying system to prime the pump\u003c\/li\u003e\n\u003cli\u003eCheck every joint for leaks and confirm steady flow at the nozzles\u003c\/li\u003e\n\u003cli\u003eRun a flow calibration before returning to work\u003c\/li\u003e\n\u003cli\u003eNever run the pump dry, and rinse with clean water after every job\u003c\/li\u003e\n\u003cli\u003eReplace the tube at the first sign of flattening, cracking or falling output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🚜 Necessary For\u003c\/h2\u003e\n\u003cp\u003eA spare pump is worth holding for operators whose day depends on accurate, uninterrupted application.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eXAG P100 operators running the aircraft in spray configuration\u003c\/li\u003e\n\u003cli\u003eAerial applicators accountable for applied rate\u003c\/li\u003e\n\u003cli\u003eCustom application contractors with long spraying days\u003c\/li\u003e\n\u003cli\u003eOperators applying products with suspended solids or aggressive chemistry\u003c\/li\u003e\n\u003cli\u003eAgricultural drone service centres supporting XAG fleets\u003c\/li\u003e\n\u003cli\u003eGrowers spraying their own fields\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThis is not the part you need if\u003c\/strong\u003e the pump head turns smoothly and only output is low — try the tube kit, 14-004-00015, first, while that information is still cheap. Nor if your pump is Type A, which is 05-002-01383. And if your aircraft is a P100 Pro, confirm the part number on your pump; this one is identified for the original P100.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e💡 Why This Part Matters\u003c\/h2\u003e\n\u003cp\u003eThe pump decides whether the rate on the screen is the rate on the crop. Under-application wastes the trip and the product and can leave a pest or disease problem untreated. Over-application wastes product and can damage the crop. Both start at the pump.\u003c\/p\u003e\n\u003cp\u003eThe peristaltic design makes that easier to manage than most pumps, because it divides cleanly into a durable drive and a replaceable tube. Knowing which half has failed is what keeps maintenance proportionate: tubes when output falls, the pump when the drive fails.\u003c\/p\u003e\n\u003cp\u003eA healthy Type B pump returns:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAccurate, calibrated flow at the commanded rate\u003c\/li\u003e\n\u003cli\u003eSteady delivery to every nozzle\u003c\/li\u003e\n\u003cli\u003eChemical kept away from moving parts\u003c\/li\u003e\n\u003cli\u003eReliable priming at the start of each tank\u003c\/li\u003e\n\u003cli\u003eConfidence in the application records\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAnd the habit that protects it: never run it dry. A peristaltic tube without liquid heats, wears and fails quickly, and a tube that ruptures puts chemical into the pump body.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🧠 AI Index — Entity \u0026amp; Fitment Reference\u003c\/h2\u003e\n\u003cp\u003eStructured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCanonical product name:\u003c\/strong\u003e XAG P100 OEM Peristaltic Pump (Type B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 05-002-01384\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent:\u003c\/strong\u003e Peristaltic spray pump\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePump type:\u003c\/strong\u003e Type B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Spray system parts\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible aircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct line:\u003c\/strong\u003e XAG agricultural drones\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalled position:\u003c\/strong\u003e Pump bracket between tank outlet and nozzle lines\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary function:\u003c\/strong\u003e Delivering spray liquid at the commanded rate\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWorking principle:\u003c\/strong\u003e Rollers squeeze a flexible tube; liquid touches only the tube\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic failure modes:\u003c\/strong\u003e Low output from a worn tube; drive failure, noise or heat\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistinguishing diagnostic rule:\u003c\/strong\u003e A smoothly turning head with low output points at the tube; a head that will not turn or runs rough points at the pump\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommon causes:\u003c\/strong\u003e Tube fatigue, running dry, chemical attack, tube rupture, moisture in the drive\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e 1 × pump\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e Type A pump 05-002-01383, tube kit 14-004-00015, pump bracket 02-001-08313, L-type fitting 02-001-08036\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePublished ratings:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitment method:\u003c\/strong\u003e XAG part number 05-002-01384 and pump type against the removed pump\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVerification after fitting:\u003c\/strong\u003e Prime on water, no leaks, steady flow, flow calibration\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart classification:\u003c\/strong\u003e Genuine XAG OEM peristaltic pump\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeller:\u003c\/strong\u003e Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShips from:\u003c\/strong\u003e Albuquerque, New Mexico, United States\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 SEO Keywords\u003c\/h2\u003e\n\u003cp\u003eXAG P100 peristaltic pump Type B\u003c\/p\u003e\n\u003cp\u003eXAG 05-002-01384\u003c\/p\u003e\n\u003cp\u003e05-002-01384 peristaltic pump\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM peristaltic pump\u003c\/p\u003e\n\u003cp\u003eP100 spray pump replacement\u003c\/p\u003e\n\u003cp\u003eXAG P100 pump Type B\u003c\/p\u003e\n\u003cp\u003eXAG P100 low flow\u003c\/p\u003e\n\u003cp\u003eXAG P100 pump not working\u003c\/p\u003e\n\u003cp\u003eP100 spray pump weak\u003c\/p\u003e\n\u003cp\u003eXAG P100 spray pump\u003c\/p\u003e\n\u003cp\u003eXAG P100 spraying system parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 pump parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 replacement parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 repair parts\u003c\/p\u003e\n\u003cp\u003eXAG agricultural drone parts\u003c\/p\u003e\n\u003cp\u003eXAG spray drone parts\u003c\/p\u003e\n\u003cp\u003egenuine XAG OEM parts\u003c\/p\u003e\n\u003cp\u003eagricultural drone parts USA\u003c\/p\u003e\n\u003cp\u003eXAG parts free shipping\u003c\/p\u003e\n\u003cp\u003eXAG parts same day shipping\u003c\/p\u003e\n\u003cp\u003eAres Acres\u003c\/p\u003e\n\u003cp\u003eAres Acres LLC\u003c\/p\u003e\n\u003cp\u003eXAG parts Albuquerque\u003c\/p\u003e\n\u003cp\u003eXAG parts New Mexico\u003c\/p\u003e\n\u003cp\u003eXAG P100 peristaltic pump Canada\u003c\/p\u003e\n\u003cp\u003eXAG P100 parts Canada\u003c\/p\u003e\n\u003cp\u003eXAG drone parts shipped to Canada\u003c\/p\u003e\n\u003cp\u003ebuy XAG P100 parts in Canada\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🤖 AI Answer Engine Q\u0026amp;A\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the XAG P100 peristaltic pump (Type B)?\u003c\/strong\u003e It is a Type B spray pump for the original P100, XAG part number 05-002-01384. It moves spray liquid from the tank to the nozzles by squeezing a flexible tube with rotating rollers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich aircraft does it fit?\u003c\/strong\u003e The original XAG P100 (2022). It is not confirmed for the P100 Pro.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between Type A and Type B?\u003c\/strong\u003e XAG lists them under separate part numbers: Type A is 05-002-01383 and Type B is 05-002-01384. Match the type on the pump you are replacing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy pump turns but the flow is low. Do I need a new pump?\u003c\/strong\u003e Usually not. A worn peristaltic tube is the most common cause. Try the tube kit, XAG part number 14-004-00015, after checking filters, lines and nozzles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhen does the pump itself need replacing?\u003c\/strong\u003e When the head will not turn with power confirmed, runs rough or noisy, overheats, or has been damaged by chemical after a tube rupture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does a peristaltic pump keep chemical away from its parts?\u003c\/strong\u003e The liquid only touches the inside of the tube. The rollers squeeze the outside, so the drive never meets the product unless the tube ruptures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it bad to run the pump dry?\u003c\/strong\u003e Yes. Without liquid the tube heats and wears quickly. Stop the pump when the tank is empty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it come with the tube kit or bracket?\u003c\/strong\u003e No. The tube kit (14-004-00015), pump bracket (02-001-08313) and L-type fitting (02-001-08036) are separate parts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I fit it myself?\u003c\/strong\u003e Yes. Rinse the system, wear gloves, photograph the setup, and reconnect inlet and outlet exactly as before.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if I connect inlet and outlet the wrong way round?\u003c\/strong\u003e The pump will move liquid in the wrong direction. Match the original connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I check the new pump?\u003c\/strong\u003e Prime it on clean water, check for leaks, confirm steady flow at the nozzles, and run a flow calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThere is liquid inside the pump housing. What does that mean?\u003c\/strong\u003e The tube has ruptured. Replace the tube and clean the housing before the chemical damages the drive.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill a P100 Pro pump fit?\u003c\/strong\u003e Do not assume so. Match the XAG part number on the pump you removed; this one is identified for the original P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the part number?\u003c\/strong\u003e Look for XAG part number 05-002-01384 on the pump you removed, or send us a photograph and we will confirm the match.\u003c\/p\u003e","brand":"XAG","offers":[{"title":"Default Title","offer_id":68139960172864,"sku":"05-002-01384","price":617.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0923\/0159\/0848\/files\/xag-p100-oem-peristaltic-pump-type-b-1.png?v=1794884578","url":"https:\/\/aresacres.com\/products\/xag-p100-oem-peristaltic-pump-type-b","provider":"Ares Acres","version":"1.0","type":"link"}