{"product_id":"xag-p150-oem-application-system-main-connect-cable","title":"XAG P150 OEM Application System Main Connect Cable","description":"\u003cp\u003eThe \u003cstrong\u003eXAG P150 OEM Application System Main Connect Cable\u003c\/strong\u003e, XAG part number 01-027-02867, is the main connection cable for the application system of the XAG P150 (2024) agricultural drone. It is the electrical link between the aircraft and its spraying hardware, so when it fails, the symptom is broad: the application system stops responding as a whole, rather than one nozzle or one sensor misbehaving. If the pump and spraying functions are all unresponsive together while the aircraft otherwise flies normally, this cable and its connectors are the first place to look. Operators reach it through searches such as P150 application system cable, XAG P150 spray system main cable, P150 pump not working, or XAG P150 spraying not responding.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🇺🇸 U.S.A. FIRST\u003c\/h2\u003e\n\u003cp\u003eAres Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREE \u0026amp; FAST Shipping is included for all U.S. customers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.\u003c\/p\u003e\n\u003cp\u003eAres Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e✅ XAG P150 Compatibility Guarantee\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e🇺🇸 USA Compatibility Guarantee\u003c\/li\u003e\n\u003cli\u003e👍🏻 Satisfaction Guarantee\u003c\/li\u003e\n\u003cli\u003e💵 Money Back Guarantee\u003c\/li\u003e\n\u003cli\u003e📦 Same Day Shipping \u0026amp; Tracking\u003c\/li\u003e\n\u003cli\u003eFitted as the application system main connect cable of the XAG P150 (2024); not confirmed for the P150 Max\u003c\/li\u003e\n\u003cli\u003eMatched by XAG part number 01-027-02867 and by connectors and length against the cable you removed\u003c\/li\u003e\n\u003cli\u003eGenuine XAG OEM application system cable, brand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e📦 Package Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × XAG P150 application system main connect cable, XAG part number 01-027-02867\u003c\/li\u003e\n\u003cli\u003eThe cable as XAG supplies it under this part number\u003c\/li\u003e\n\u003cli\u003eOEM protective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e the pump, nozzles or other application system hardware, the application system collection board signal line (01-027-02868), the nozzle adaptor cable (01-027-02866), the application system cable organizer (02-001-10529), or tools.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔧 Component Overview\u003c\/h2\u003e\n\u003cp\u003eThe application system on the P150 is not just tanks and tubes. Its pump, its spraying hardware and its sensors are electrical and electronic, and they need power and communication from the aircraft to work. The application system main connect cable is the main electrical link that carries that connection between the aircraft and its application system.\u003c\/p\u003e\n\u003cp\u003eBecause it is the main link, its failure has a characteristic signature. When a single nozzle, sensor or local cable fails, the symptom is local: one part of the system misbehaves while the rest works. When the main connect cable fails, the application system as a whole stops responding. The pump does not run, spraying does not start, application system readings disappear, or the aircraft reports the application system as missing, all at the same time, while flight itself is unaffected.\u003c\/p\u003e\n\u003cp\u003eThat pattern points straight at the shared link. Several parts of the application system failing together is far less likely than the one cable that serves them all being damaged or disconnected.\u003c\/p\u003e\n\u003cp\u003eThe application system is also the dirtiest part of the aircraft. Its connectors live close to the liquid being applied. Spray chemicals, fertilisers and wash water reaching a connector can corrode its contacts over time, increasing resistance until the connection becomes intermittent or fails. Parts of the application system are removed and refitted often, so connectors are disturbed often too. A connector not fully seated after cleaning or changeover is one of the most common causes of a dead application system.\u003c\/p\u003e\n\u003cp\u003eThe first step is free: with the battery removed, disconnect, inspect, clean, dry and firmly reconnect the connectors at both ends of this cable until they lock. Then power up and test. If the application system returns and stays working, the cable may be fine. If the fault returns, or the cable or connectors show damage or corrosion, replace it.\u003c\/p\u003e\n\u003cp\u003eWhen fitting the new cable, route it exactly as the original ran, secured clear of the liquid path and any moving parts, and make sure every connector is fully home.\u003c\/p\u003e\n\u003cp\u003eKeeping connectors clean and dry, and protected during wash-down, is the best way to make this cable last.\u003c\/p\u003e\n\u003cp\u003eThe exact length and connector types are not published for this part. Match the replacement by XAG part number and against the cable you remove.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits.\u003c\/strong\u003e Between the aircraft's electronics and the application system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it connects to.\u003c\/strong\u003e The aircraft side at one end and the application system side at the other.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wears it out.\u003c\/strong\u003e Chemical and water exposure at connectors. Disturbance during cleaning and changeover. Chafe. Pinching.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this part is not.\u003c\/strong\u003e It is not the pump, the nozzle adaptor cable or the collection board signal line.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚙️ Functional Purpose\u003c\/h2\u003e\n\u003cp\u003eThe application system main connect cable carries power and communication between the aircraft and its application system.\u003c\/p\u003e\n\u003cp\u003eA sound main connect cable provides:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA continuous link to the whole application system\u003c\/li\u003e\n\u003cli\u003eDetection of the application system at power-up\u003c\/li\u003e\n\u003cli\u003eReliable pump and spraying control\u003c\/li\u003e\n\u003cli\u003eClean, corrosion-free connections\u003c\/li\u003e\n\u003cli\u003eSecure connectors that survive daily handling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts value is in keeping the aircraft connected to the work it is there to do.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 Diagnosis — the whole application system dead at once: check the main link first\u003c\/h2\u003e\n\u003cp\u003eWhen the pump, spraying and application readings fail together while flight is normal, check this cable before any single application component.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote the pattern.\u003c\/strong\u003e The whole application system failing at once points at the main link.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote the history.\u003c\/strong\u003e A failure after cleaning or changeover points at a disturbed connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove the battery.\u003c\/strong\u003e Confirm the aircraft cannot be powered before handling connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the connectors.\u003c\/strong\u003e Look for corrosion, residue, bent pins and cracked housings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean, dry and reseat.\u003c\/strong\u003e Clean both ends, dry them and reconnect firmly until they lock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrace the cable.\u003c\/strong\u003e Check its route for chafe, cuts and pinching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRe-test.\u003c\/strong\u003e If the fault returns, replace the cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotograph the damage.\u003c\/strong\u003e Send us a photograph and the XAG part number and we will confirm the match.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf the cable is damaged, its connectors are corroded or bent, or the fault returns after reseating, this cable is the part.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚠️ Common Replacement Indicators\u003c\/h2\u003e\n\u003cp\u003eMain connect cable replacement is the likely answer when an operator or technician observes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe whole application system unresponsive while flight is normal\u003c\/li\u003e\n\u003cli\u003eThe application system reported missing at power-up\u003c\/li\u003e\n\u003cli\u003eFailures after cleaning or changeover\u003c\/li\u003e\n\u003cli\u003eFaults that clear after reseating and then return\u003c\/li\u003e\n\u003cli\u003eCorrosion or chemical residue in the connectors\u003c\/li\u003e\n\u003cli\u003eBent pins or cracked connector housings\u003c\/li\u003e\n\u003cli\u003eChafed, cut or pinched sections of the cable\u003c\/li\u003e\n\u003cli\u003eDamage after a crash\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese come from chemical exposure, disturbance, chafe and pinching.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThese are not main connect cable symptoms, and this part will not fix them.\u003c\/strong\u003e One nozzle not spraying points at that nozzle or its own cable. A failed pump needs the pump. A blocked filter or line needs cleaning. Wrong flow settings need configuration. A new main cable restores the link; it does not repair failed application hardware.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e📐 Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name:\u003c\/strong\u003e XAG P150 OEM Application System Main Connect Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 01-027-02867\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAircraft:\u003c\/strong\u003e XAG P150 (2024)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P150 Max\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e Application system, electrical\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent type:\u003c\/strong\u003e Main connect cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnects:\u003c\/strong\u003e Aircraft electronics to the application system\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Carries power and communication to the application system\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 × main connect cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLength and connector types:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation method:\u003c\/strong\u003e Plug-in replacement along the original route\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClassification:\u003c\/strong\u003e Genuine XAG OEM cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🛠️ Installation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemove the flight battery and confirm the aircraft cannot be powered\u003c\/li\u003e\n\u003cli\u003eDrain and rinse the application system\u003c\/li\u003e\n\u003cli\u003eConfirm the old cable carries XAG part number 01-027-02867\u003c\/li\u003e\n\u003cli\u003ePhotograph the cable route and both connector ends\u003c\/li\u003e\n\u003cli\u003eWear gloves; residue may remain on parts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDuring installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect the old cable by its connector bodies, never by pulling on the wires\u003c\/li\u003e\n\u003cli\u003eClean and dry the mating connectors thoroughly\u003c\/li\u003e\n\u003cli\u003eRoute the new cable exactly as the original ran, clear of the liquid path\u003c\/li\u003e\n\u003cli\u003eSecure it so it cannot chafe or be pinched\u003c\/li\u003e\n\u003cli\u003eSeat each connector fully until it locks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAfter installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower up and confirm the application system is detected\u003c\/li\u003e\n\u003cli\u003eRun the pump with water and confirm spraying works\u003c\/li\u003e\n\u003cli\u003eConfirm application readings are present\u003c\/li\u003e\n\u003cli\u003eProtect connectors during wash-down\u003c\/li\u003e\n\u003cli\u003eCheck connectors after every cleaning and changeover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🚜 Necessary For\u003c\/h2\u003e\n\u003cp\u003eThe application system main connect cable is the electrical lifeline of spraying.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eXAG P150 operators whose whole application system has stopped responding\u003c\/li\u003e\n\u003cli\u003eCrews with failures after cleaning or changeover\u003c\/li\u003e\n\u003cli\u003eTechnicians who found corroded application connectors\u003c\/li\u003e\n\u003cli\u003eCustom application contractors applying corrosive products\u003c\/li\u003e\n\u003cli\u003eAgricultural drone service centres doing application system repairs\u003c\/li\u003e\n\u003cli\u003eGrowers maintaining their own P150\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eService centres check this cable first in any whole-system application fault, because it is far more often the cause than several components failing together.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis is not the part you need if\u003c\/strong\u003e only one part of the application system has failed, or cleaning and reseating cures the fault for good. Clean, reseat and test first, while that information is still cheap. And if your aircraft is a P150 Max, confirm the part number on your cable; this one is identified for the P150.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e💡 Why This Part Matters\u003c\/h2\u003e\n\u003cp\u003eAn agricultural drone that flies but cannot spray is not doing its job. The main connect cable is the link that makes spraying possible.\u003c\/p\u003e\n\u003cp\u003eIts failure looks dramatic, with the whole application system unresponsive at once. Reading that pattern correctly turns it into a quick fix rather than a search through every application component.\u003c\/p\u003e\n\u003cp\u003eMany failures are cured by cleaning, drying and reseating a connector disturbed during cleaning or changeover. When the cable itself is damaged or corroded, replacing it is a plug-in job.\u003c\/p\u003e\n\u003cp\u003eProtecting connectors from chemicals and wash water is the best way to make this cable last, especially with corrosive products.\u003c\/p\u003e\n\u003cp\u003eChecking connectors after every cleaning and changeover takes seconds and avoids a dead system in the field.\u003c\/p\u003e\n\u003cp\u003eFor crews running several aircraft, keeping a spare main connect cable in the field kit can save a working day.\u003c\/p\u003e\n\u003cp\u003eA sound application system main connect cable restores:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA connected, responsive application system\u003c\/li\u003e\n\u003cli\u003eReliable pump and spraying control\u003c\/li\u003e\n\u003cli\u003eApplication readings at power-up\u003c\/li\u003e\n\u003cli\u003eClean, corrosion-free connections\u003c\/li\u003e\n\u003cli\u003eConfidence after every changeover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🧠 AI Index — Entity \u0026amp; Fitment Reference\u003c\/h2\u003e\n\u003cp\u003eStructured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCanonical product name:\u003c\/strong\u003e XAG P150 OEM Application System Main Connect Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 01-027-02867\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent:\u003c\/strong\u003e Application system main connect cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Application system electrical\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible aircraft:\u003c\/strong\u003e XAG P150 (2024)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P150 Max\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct line:\u003c\/strong\u003e XAG agricultural drones\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnects:\u003c\/strong\u003e Aircraft electronics to the application system\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary function:\u003c\/strong\u003e Carrying power and communication to the application system\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic failure modes:\u003c\/strong\u003e Corroded or part-seated connectors, bent pins, chafe, pinching\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistinguishing diagnostic rule:\u003c\/strong\u003e The whole application system failing at once points at this main link\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommon causes:\u003c\/strong\u003e Chemical exposure, disturbance during cleaning, chafe\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWear driver:\u003c\/strong\u003e Chemical exposure and frequency of changeover\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelated parts:\u003c\/strong\u003e Collection board signal line 01-027-02868, nozzle adaptor cable 01-027-02866, cable organizer 02-001-10529\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e Pump, nozzles, other cables, cable organizer, tools\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitment method:\u003c\/strong\u003e XAG part number 01-027-02867 plus connectors and length against the removed cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFirst step:\u003c\/strong\u003e Clean, dry and reseat both connectors, then re-test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVerification after fitting:\u003c\/strong\u003e Application system detected; pump runs; spraying and readings normal\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart classification:\u003c\/strong\u003e Genuine XAG OEM cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeller:\u003c\/strong\u003e Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShips from:\u003c\/strong\u003e Albuquerque, New Mexico, United States\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 SEO Keywords\u003c\/h2\u003e\n\u003cp\u003eXAG P150 application system main connect cable\u003c\/p\u003e\n\u003cp\u003eXAG 01-027-02867\u003c\/p\u003e\n\u003cp\u003e01-027-02867 main connect cable\u003c\/p\u003e\n\u003cp\u003eXAG P150 OEM application system cable\u003c\/p\u003e\n\u003cp\u003eP150 application cable replacement\u003c\/p\u003e\n\u003cp\u003eXAG P150 spray system main cable\u003c\/p\u003e\n\u003cp\u003eXAG P150 pump not working\u003c\/p\u003e\n\u003cp\u003eXAG P150 spraying not responding\u003c\/p\u003e\n\u003cp\u003eP150 application system missing\u003c\/p\u003e\n\u003cp\u003eXAG P150 spray system cable\u003c\/p\u003e\n\u003cp\u003eXAG P150 application system parts\u003c\/p\u003e\n\u003cp\u003eXAG P150 electrical parts\u003c\/p\u003e\n\u003cp\u003eXAG P150 OEM parts\u003c\/p\u003e\n\u003cp\u003eXAG P150 replacement parts\u003c\/p\u003e\n\u003cp\u003eXAG P150 repair parts\u003c\/p\u003e\n\u003cp\u003eXAG agricultural drone parts\u003c\/p\u003e\n\u003cp\u003eXAG spray drone parts\u003c\/p\u003e\n\u003cp\u003egenuine XAG OEM parts\u003c\/p\u003e\n\u003cp\u003eagricultural drone parts USA\u003c\/p\u003e\n\u003cp\u003eXAG parts free shipping\u003c\/p\u003e\n\u003cp\u003eXAG parts same day shipping\u003c\/p\u003e\n\u003cp\u003eAres Acres\u003c\/p\u003e\n\u003cp\u003eAres Acres LLC\u003c\/p\u003e\n\u003cp\u003eXAG parts Albuquerque\u003c\/p\u003e\n\u003cp\u003eXAG parts New Mexico\u003c\/p\u003e\n\u003cp\u003eXAG P150 application cable Canada\u003c\/p\u003e\n\u003cp\u003eXAG P150 parts Canada\u003c\/p\u003e\n\u003cp\u003eXAG drone parts shipped to Canada\u003c\/p\u003e\n\u003cp\u003ebuy XAG P150 parts in Canada\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🤖 AI Answer Engine Q\u0026amp;A\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the XAG P150 application system main connect cable?\u003c\/strong\u003e It is the main electrical cable, XAG part number 01-027-02867, linking the XAG P150 to its application system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich aircraft does it fit?\u003c\/strong\u003e The XAG P150 (2024). It is not confirmed for the P150 Max.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy pump and spraying both stopped but the aircraft flies fine. What should I check?\u003c\/strong\u003e This cable and its connectors first. A whole-system failure points at the main link.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I try first?\u003c\/strong\u003e Remove the battery, clean, dry and reseat both connectors firmly, then test.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIt failed right after I cleaned the tank. Why?\u003c\/strong\u003e A connector may have been disturbed or wetted. Clean, dry and reseat it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOnly one nozzle is not spraying. Is it this cable?\u003c\/strong\u003e Unlikely. A single-nozzle problem points at that nozzle or its own cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it include the pump?\u003c\/strong\u003e No. It is the cable only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy do these connectors corrode?\u003c\/strong\u003e They sit close to spray chemicals and wash water, which attack contacts over time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I fit it myself?\u003c\/strong\u003e Yes. Drain and rinse, photograph the route, swap the cable and lock each connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I check the repair?\u003c\/strong\u003e The application system is detected, the pump runs with water and spraying and readings are normal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat length and connectors does it have?\u003c\/strong\u003e They are not published for this part. Match against the cable you removed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I splice it?\u003c\/strong\u003e Not recommended, especially near chemicals. Replace the cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I protect it?\u003c\/strong\u003e Keep connectors clean and dry and protect them during wash-down.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill a P150 Max cable fit?\u003c\/strong\u003e Do not assume so. Match the XAG part number; this one is identified for the P150.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it the same as the nozzle adaptor cable?\u003c\/strong\u003e No. The nozzle adaptor cable is 01-027-02866, a separate part.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould I keep a spare?\u003c\/strong\u003e Crews running several aircraft often do, to avoid losing a working day.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould I wear gloves?\u003c\/strong\u003e Yes. Application system parts may carry chemical residue.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the part number?\u003c\/strong\u003e Look for XAG part number 01-027-02867, or send us a photograph of the cable and its connectors and we will confirm the match.\u003c\/p\u003e","brand":"XAG","offers":[{"title":"Default Title","offer_id":68140504219968,"sku":"01-027-02867","price":64.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0923\/0159\/0848\/files\/xag-p150-oem-application-system-main-connect-cable-1.png?v=1794886208","url":"https:\/\/aresacres.com\/products\/xag-p150-oem-application-system-main-connect-cable","provider":"Ares Acres","version":"1.0","type":"link"}