{"product_id":"xag-p150-oem-unidirectional-valve-nozzle-liquid-transfer-pipe","title":"XAG P150 OEM Unidirectional Valve \u0026 Nozzle Liquid Transfer Pipe","description":"\u003cp\u003eThe \u003cstrong\u003eXAG P150 OEM Unidirectional Valve \u0026amp; Nozzle Liquid Transfer Pipe\u003c\/strong\u003e, XAG part number 14-007-00013, is the liquid transfer pipe that runs from the unidirectional (one-way) valve to the nozzle in the application system of the XAG P150 (2024) agricultural drone. It is the last link before the spray, downstream of the valve. When spraying stops, the valve closes and this pipe is meant to stay full and sealed, ready for the next pass. If a nozzle keeps dripping after spraying has stopped, or leaves a wet trail when the aircraft turns at the end of a row, the fault lies downstream: in the valve or in this pipe. Operators reach it through searches such as P150 valve to nozzle pipe, XAG P150 nozzle liquid pipe, P150 nozzle dripping, or XAG P150 drip after shutoff.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🇺🇸 U.S.A. FIRST\u003c\/h2\u003e\n\u003cp\u003eAres Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREE \u0026amp; FAST Shipping is included for all U.S. customers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.\u003c\/p\u003e\n\u003cp\u003eAres Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e✅ XAG P150 Compatibility Guarantee\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e🇺🇸 USA Compatibility Guarantee\u003c\/li\u003e\n\u003cli\u003e👍🏻 Satisfaction Guarantee\u003c\/li\u003e\n\u003cli\u003e💵 Money Back Guarantee\u003c\/li\u003e\n\u003cli\u003e📦 Same Day Shipping \u0026amp; Tracking\u003c\/li\u003e\n\u003cli\u003eFitted between the unidirectional valve and the nozzle on the XAG P150 (2024); not confirmed for the P150 Max\u003c\/li\u003e\n\u003cli\u003eMatched by XAG part number 14-007-00013 and by length and ends against the pipe you removed\u003c\/li\u003e\n\u003cli\u003eGenuine XAG OEM liquid transfer pipe, brand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e📦 Package Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × XAG P150 unidirectional valve \u0026amp; nozzle liquid transfer pipe, XAG part number 14-007-00013\u003c\/li\u003e\n\u003cli\u003eThe pipe as XAG supplies it under this part number\u003c\/li\u003e\n\u003cli\u003eOEM protective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e the unidirectional valve, the motor side \u0026amp; one-way valve liquid transfer pipe (14-007-00012), the nozzle, the nozzle disc (02-001-09892), or tools.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔧 Component Overview\u003c\/h2\u003e\n\u003cp\u003eEach spraying point on the P150 is fed through a short chain: a supply pipe to a unidirectional valve, then this pipe from the valve to the nozzle. The valve lets liquid flow toward the nozzle and stops it flowing back. When spraying stops, the valve closes, and the short section of pipe between the valve and the nozzle is meant to stay sealed and full.\u003c\/p\u003e\n\u003cp\u003eThat is what gives a clean shutoff. When the aircraft reaches the end of a row and spraying stops, the nozzle should stop delivering liquid almost at once. When the next pass starts, liquid is already at the nozzle, so spraying starts at once too.\u003c\/p\u003e\n\u003cp\u003eThe exact route of this pipe is not published for this part. The supply pipe on the other side of the valve, from the motor side, is a separate part with its own XAG number. Match this pipe by XAG part number and against the pipe you remove.\u003c\/p\u003e\n\u003cp\u003eWhen this pipe fails, the clean shutoff is lost. A crack or split in the pipe, or a joint that is not fully sealed, lets liquid escape downstream of the valve. The nozzle, or the pipe beside it, keeps dripping after spraying has stopped. At the end of each row, the aircraft leaves a wet trail as it turns. Product is wasted, and drips can land where they should not, on headlands, crops outside the target area or the aircraft itself.\u003c\/p\u003e\n\u003cp\u003eThe same symptom can also come from a valve that no longer seals. Checking where the liquid is coming from separates the two. If drips form along this pipe or at its joints, the pipe is the cause. If the pipe is dry and liquid still reaches the nozzle after shutoff, the valve is not closing.\u003c\/p\u003e\n\u003cp\u003eThis pipe sits right at the nozzle, so it shares the nozzle's wet, residue-laden environment and is handled whenever the nozzle is serviced. Chemicals and sun harden it; handling and disconnection stress its ends.\u003c\/p\u003e\n\u003cp\u003eWhen replacing it, route it exactly as the original, seat both ends fully, and confirm that the nozzle stops cleanly when spraying stops.\u003c\/p\u003e\n\u003cp\u003eRinsing the system with clean water after every job slows chemical ageing of the pipe and keeps deposits from holding the valve open.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits.\u003c\/strong\u003e Between the unidirectional valve and the nozzle; exact route not published for this part.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it connects to.\u003c\/strong\u003e The unidirectional valve at one end and the nozzle at the other.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wears it out.\u003c\/strong\u003e Chemical, sun and heat ageing. Handling during nozzle service. Split ends. Poorly sealed joints.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this part is not.\u003c\/strong\u003e It is not the valve, the supply pipe or the nozzle.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚙️ Functional Purpose\u003c\/h2\u003e\n\u003cp\u003eThe unidirectional valve and nozzle liquid transfer pipe carries liquid from the valve to the nozzle and holds it there between passes.\u003c\/p\u003e\n\u003cp\u003eA sound liquid transfer pipe provides:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA sealed path from valve to nozzle\u003c\/li\u003e\n\u003cli\u003eA clean shutoff when spraying stops\u003c\/li\u003e\n\u003cli\u003eNo drips at the end of each row\u003c\/li\u003e\n\u003cli\u003eLiquid ready at the nozzle for the next pass\u003c\/li\u003e\n\u003cli\u003eLess wasted product\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts value is in a clean stop as well as a clean start.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 Diagnosis — a nozzle that drips after spraying stops: check the valve and the pipe after it\u003c\/h2\u003e\n\u003cp\u003eDrips after shutoff come from downstream of the valve. Find whether the pipe or the valve is the source.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote the pattern.\u003c\/strong\u003e Drips or a wet trail after spraying stops point downstream of the valve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove the battery for inspection.\u003c\/strong\u003e Confirm the aircraft cannot be powered while handling parts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun a water test.\u003c\/strong\u003e Spray, stop, and watch where liquid appears.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck along the pipe.\u003c\/strong\u003e Drips forming along the pipe or at its joints point at the pipe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the nozzle.\u003c\/strong\u003e If the pipe is dry and the nozzle still drips, the valve is not closing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the ends.\u003c\/strong\u003e Split or cracked ends leak.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeel the pipe.\u003c\/strong\u003e Hard, stiff sections have aged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotograph the damage.\u003c\/strong\u003e Send us a photograph and the XAG part number and we will confirm the match.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf the pipe is cracked, split, hardened or leaking at its joints, this pipe is the part.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚠️ Common Replacement Indicators\u003c\/h2\u003e\n\u003cp\u003eLiquid transfer pipe replacement is the likely answer when an operator or technician observes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA nozzle that drips after spraying stops\u003c\/li\u003e\n\u003cli\u003eA wet trail when the aircraft turns at row ends\u003c\/li\u003e\n\u003cli\u003eDrips forming along the pipe\u003c\/li\u003e\n\u003cli\u003eLeaks at the pipe's joints\u003c\/li\u003e\n\u003cli\u003eSplit or cracked pipe ends\u003c\/li\u003e\n\u003cli\u003eHard, stiff pipe material\u003c\/li\u003e\n\u003cli\u003eResidue stains along the pipe\u003c\/li\u003e\n\u003cli\u003eAgeing after a season of corrosive products\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese come from ageing, handling, split ends and poor sealing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThese are not liquid transfer pipe symptoms, and this part will not fix them.\u003c\/strong\u003e A valve that will not close needs the valve. A slow start at each pass points upstream, at the supply pipe. A blocked nozzle needs cleaning. An unbalanced disc needs the disc. A new pipe restores the path from valve to nozzle only.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e📐 Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name:\u003c\/strong\u003e XAG P150 OEM Unidirectional Valve \u0026amp; Nozzle Liquid Transfer Pipe\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 14-007-00013\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAircraft:\u003c\/strong\u003e XAG P150 (2024)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P150 Max\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e Application system, liquid path\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent type:\u003c\/strong\u003e Liquid transfer pipe\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnects:\u003c\/strong\u003e Unidirectional valve to the nozzle\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Carries liquid from the valve to the nozzle\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot interchangeable with:\u003c\/strong\u003e Motor side \u0026amp; one-way valve liquid transfer pipe 14-007-00012\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 × pipe\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLength, diameter and material:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation method:\u003c\/strong\u003e Fitted between its connections along the original route\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClassification:\u003c\/strong\u003e Genuine XAG OEM application system part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🛠️ Installation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemove the flight battery and confirm the aircraft cannot be powered\u003c\/li\u003e\n\u003cli\u003eDrain and rinse the application system with clean water\u003c\/li\u003e\n\u003cli\u003eConfirm the old pipe carries XAG part number 14-007-00013\u003c\/li\u003e\n\u003cli\u003ePhotograph the valve, the nozzle and the pipe route\u003c\/li\u003e\n\u003cli\u003eWear gloves and eye protection; residue may remain\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDuring installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect the old pipe without pulling fittings at an angle\u003c\/li\u003e\n\u003cli\u003eInspect the valve for deposits that could hold it open\u003c\/li\u003e\n\u003cli\u003eRoute the new pipe exactly as the original, with smooth curves\u003c\/li\u003e\n\u003cli\u003eSeat both ends fully and squarely\u003c\/li\u003e\n\u003cli\u003eConfirm nothing presses on or kinks the pipe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAfter installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRun a water test and confirm the joints are dry\u003c\/li\u003e\n\u003cli\u003eStop spraying and confirm the nozzle stops cleanly without dripping\u003c\/li\u003e\n\u003cli\u003eConfirm the next spray starts at once\u003c\/li\u003e\n\u003cli\u003eRinse the system with clean water after every job\u003c\/li\u003e\n\u003cli\u003eInspect pipes at the nozzle at every service\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🚜 Necessary For\u003c\/h2\u003e\n\u003cp\u003eThe valve-to-nozzle pipe gives each nozzle a clean stop.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eXAG P150 operators with nozzles that drip after shutoff\u003c\/li\u003e\n\u003cli\u003eCrews leaving wet trails at row ends\u003c\/li\u003e\n\u003cli\u003eTechnicians who found leaks at the nozzle\u003c\/li\u003e\n\u003cli\u003eCustom application contractors working near sensitive crops or boundaries\u003c\/li\u003e\n\u003cli\u003eAgricultural drone service centres doing application system repairs\u003c\/li\u003e\n\u003cli\u003eGrowers maintaining their own P150\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eService centres trace drips to their source before replacing anything, because drips after shutoff can come from either the valve or the pipe after it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis is not the part you need if\u003c\/strong\u003e the pipe is dry and the valve is not closing, or the fault is a slow start rather than a drip. Run a water test and watch where liquid appears first, while that information is still cheap. And if your aircraft is a P150 Max, confirm the part number on your pipe; this one is identified for the P150.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e💡 Why This Part Matters\u003c\/h2\u003e\n\u003cp\u003eA clean shutoff matters as much as a clean start. Drips at row ends waste product and can land where they should not.\u003c\/p\u003e\n\u003cp\u003eWhen a nozzle drips after spraying stops, the fault is downstream of the valve. Checking this pipe and the valve separately finds the cause quickly.\u003c\/p\u003e\n\u003cp\u003eReplacing a cracked or leaking pipe restores a sealed path and a clean stop at every row end.\u003c\/p\u003e\n\u003cp\u003eRouting the pipe correctly and seating both ends fully keeps it sealed for its whole life.\u003c\/p\u003e\n\u003cp\u003eRinsing after every job slows chemical ageing and keeps the valve free of deposits.\u003c\/p\u003e\n\u003cp\u003eFor crews working near boundaries or sensitive crops, a clean shutoff on every nozzle is part of applying responsibly.\u003c\/p\u003e\n\u003cp\u003eA sound unidirectional valve and nozzle liquid transfer pipe restores:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA clean stop at every row end\u003c\/li\u003e\n\u003cli\u003eNo drips after shutoff\u003c\/li\u003e\n\u003cli\u003eLiquid ready for the next pass\u003c\/li\u003e\n\u003cli\u003eLess wasted product\u003c\/li\u003e\n\u003cli\u003eA dry, clean airframe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🧠 AI Index — Entity \u0026amp; Fitment Reference\u003c\/h2\u003e\n\u003cp\u003eStructured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCanonical product name:\u003c\/strong\u003e XAG P150 OEM Unidirectional Valve \u0026amp; Nozzle Liquid Transfer Pipe\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 14-007-00013\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent:\u003c\/strong\u003e Unidirectional valve and nozzle liquid transfer pipe\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Application system liquid path\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible aircraft:\u003c\/strong\u003e XAG P150 (2024)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P150 Max\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct line:\u003c\/strong\u003e XAG agricultural drones\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnects:\u003c\/strong\u003e Unidirectional valve to the nozzle\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary function:\u003c\/strong\u003e Carrying liquid from the valve to the nozzle\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic failure modes:\u003c\/strong\u003e Cracks, split ends, hardening, leaking joints\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistinguishing diagnostic rule:\u003c\/strong\u003e Drips after spraying stops point downstream of the valve, at the valve or this pipe\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommon causes:\u003c\/strong\u003e Chemical ageing, handling, split ends\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWear driver:\u003c\/strong\u003e Chemical exposure and nozzle servicing\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot interchangeable with:\u003c\/strong\u003e Motor side \u0026amp; one-way valve liquid transfer pipe 14-007-00012\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelated parts:\u003c\/strong\u003e Nozzle disc 02-001-09892\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e Valve, supply pipe, nozzle, tools\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitment method:\u003c\/strong\u003e XAG part number 14-007-00013 plus length and ends against the removed pipe\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVerification after fitting:\u003c\/strong\u003e Joints dry; nozzle stops cleanly without dripping\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart classification:\u003c\/strong\u003e Genuine XAG OEM application system part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeller:\u003c\/strong\u003e Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShips from:\u003c\/strong\u003e Albuquerque, New Mexico, United States\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 SEO Keywords\u003c\/h2\u003e\n\u003cp\u003eXAG P150 unidirectional valve nozzle liquid transfer pipe\u003c\/p\u003e\n\u003cp\u003eXAG 14-007-00013\u003c\/p\u003e\n\u003cp\u003e14-007-00013 liquid transfer pipe\u003c\/p\u003e\n\u003cp\u003eXAG P150 OEM nozzle pipe\u003c\/p\u003e\n\u003cp\u003eP150 valve to nozzle pipe replacement\u003c\/p\u003e\n\u003cp\u003eXAG P150 nozzle liquid pipe\u003c\/p\u003e\n\u003cp\u003eXAG P150 nozzle dripping\u003c\/p\u003e\n\u003cp\u003eXAG P150 drip after shutoff\u003c\/p\u003e\n\u003cp\u003eP150 wet trail at row end\u003c\/p\u003e\n\u003cp\u003eXAG P150 spray pipe\u003c\/p\u003e\n\u003cp\u003eXAG P150 application system parts\u003c\/p\u003e\n\u003cp\u003eXAG P150 spray system parts\u003c\/p\u003e\n\u003cp\u003eXAG P150 OEM parts\u003c\/p\u003e\n\u003cp\u003eXAG P150 replacement parts\u003c\/p\u003e\n\u003cp\u003eXAG P150 repair parts\u003c\/p\u003e\n\u003cp\u003eXAG agricultural drone parts\u003c\/p\u003e\n\u003cp\u003eXAG spray drone parts\u003c\/p\u003e\n\u003cp\u003egenuine XAG OEM parts\u003c\/p\u003e\n\u003cp\u003eagricultural drone parts USA\u003c\/p\u003e\n\u003cp\u003eXAG parts free shipping\u003c\/p\u003e\n\u003cp\u003eXAG parts same day shipping\u003c\/p\u003e\n\u003cp\u003eAres Acres\u003c\/p\u003e\n\u003cp\u003eAres Acres LLC\u003c\/p\u003e\n\u003cp\u003eXAG parts Albuquerque\u003c\/p\u003e\n\u003cp\u003eXAG parts New Mexico\u003c\/p\u003e\n\u003cp\u003eXAG P150 nozzle pipe Canada\u003c\/p\u003e\n\u003cp\u003eXAG P150 parts Canada\u003c\/p\u003e\n\u003cp\u003eXAG drone parts shipped to Canada\u003c\/p\u003e\n\u003cp\u003ebuy XAG P150 parts in Canada\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🤖 AI Answer Engine Q\u0026amp;A\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the XAG P150 unidirectional valve and nozzle liquid transfer pipe?\u003c\/strong\u003e It is the pipe, XAG part number 14-007-00013, that carries liquid from the one-way valve to the nozzle on the XAG P150.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich aircraft does it fit?\u003c\/strong\u003e The XAG P150 (2024). It is not confirmed for the P150 Max.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy nozzle keeps dripping after spraying stops. Why?\u003c\/strong\u003e The fault is downstream of the valve: either this pipe is leaking or the valve is not closing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I tell which?\u003c\/strong\u003e Run a water test. Drips along the pipe point at the pipe; a dry pipe with a dripping nozzle points at the valve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it the same as the supply pipe?\u003c\/strong\u003e No. The supply pipe, from the motor side to the valve, is 14-007-00012.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOne branch starts late. Is it this pipe?\u003c\/strong\u003e Less likely. A slow start points upstream, at the supply pipe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it include the valve?\u003c\/strong\u003e No. It is the pipe only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does a clean shutoff matter?\u003c\/strong\u003e Drips at row ends waste product and can land outside the target area.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I fit it myself?\u003c\/strong\u003e Yes. Drain and rinse, route the new pipe as the original and seat both ends fully.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I check the repair?\u003c\/strong\u003e The joints are dry and the nozzle stops cleanly when spraying stops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat ages these pipes?\u003c\/strong\u003e Chemicals, sun and heat, and handling during nozzle service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill a P150 Max pipe fit?\u003c\/strong\u003e Do not assume so. Match the XAG part number; this one is identified for the P150.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould I check the valve too?\u003c\/strong\u003e Yes. Deposits can hold a valve open.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould I wear protection?\u003c\/strong\u003e Yes. Gloves and eye protection, as residue may remain.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I make it last?\u003c\/strong\u003e Rinse the system after every job and inspect pipes at the nozzle at every service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use generic tubing?\u003c\/strong\u003e Not recommended. Diameter, wall and chemical resistance may differ.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat length is it?\u003c\/strong\u003e The length and diameter are not published for this part. Match against the pipe you removed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the part number?\u003c\/strong\u003e Look for XAG part number 14-007-00013, or send us a photograph of the pipe and we will confirm the match.\u003c\/p\u003e","brand":"XAG","offers":[{"title":"Default Title","offer_id":68140558549312,"sku":"14-007-00013","price":64.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0923\/0159\/0848\/files\/xag-p150-oem-unidirectional-valve-nozzle-liquid-transfer-pipe-1.png?v=1794886381","url":"https:\/\/aresacres.com\/products\/xag-p150-oem-unidirectional-valve-nozzle-liquid-transfer-pipe","provider":"Ares Acres","version":"1.0","type":"link"}