{"product_id":"xag-p100-oem-application-system-cable-hub-board","title":"XAG P100 OEM Application System Cable Hub Board","description":"\u003cp\u003eThe \u003cstrong\u003eXAG P100 OEM Application System Cable Hub Board\u003c\/strong\u003e, XAG part number 05-002-01310, is the circuit board inside the application system cable hub of the original XAG P100 (2022) agricultural drone. Application system faults have a natural order of suspects. Try the module on another aircraft; if it works there, the module is sound. Check and, if needed, replace the main connect cable. If the fault survives a sound module and a sound cable, and the hub case is closed and dry, the board inside the hub is what remains. Opening the hub at that point usually shows why: corrosion, heat marks or a damaged connector on the board. Operators reach it through searches such as P100 cable hub board, XAG P100 application system hub board, P100 spray module fault, or XAG P100 hub circuit board.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🇺🇸 U.S.A. FIRST\u003c\/h2\u003e\n\u003cp\u003eAres Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREE \u0026amp; FAST Shipping is included for all U.S. customers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.\u003c\/p\u003e\n\u003cp\u003eAres Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e✅ XAG P100 Compatibility Guarantee\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e🇺🇸 USA Compatibility Guarantee\u003c\/li\u003e\n\u003cli\u003e👍🏻 Satisfaction Guarantee\u003c\/li\u003e\n\u003cli\u003e💵 Money Back Guarantee\u003c\/li\u003e\n\u003cli\u003e📦 Same Day Shipping \u0026amp; Tracking\u003c\/li\u003e\n\u003cli\u003eFitted as the circuit board inside the application system cable hub of the original XAG P100 (2022); not confirmed for the P100 Pro\u003c\/li\u003e\n\u003cli\u003eMatched by XAG part number 05-002-01310 and against the board you removed\u003c\/li\u003e\n\u003cli\u003eGenuine XAG OEM circuit board, brand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e📦 Package Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eXAG P100 application system cable hub board, XAG part number 05-002-01310\u003c\/li\u003e\n\u003cli\u003eOne board as XAG supplies it under this part number\u003c\/li\u003e\n\u003cli\u003eOEM antistatic protective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhether any cables or connectors come attached to the board is not published for this part. Compare it against the board you are replacing, or ask us and we will confirm before dispatch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e the cable hub upper case (02-001-08070), the cable hub lower case (02-001-08071), the application system main connect cable (01-027-02338), the central cable hub (14-005-00034), or tools.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔧 Component Overview\u003c\/h2\u003e\n\u003cp\u003eThe original P100's application system, its spray or spread module, connects to the aircraft through a cable hub. The hub has an upper case, a lower case and, inside them, this circuit board. The board is where the application system's connections meet and are distributed. Its circuit design and functions in detail are not published for this part.\u003c\/p\u003e\n\u003cp\u003eBecause the board sits in a sealed case, it is the most protected part of the application system connection, and usually the last to fail. Modules are handled at every change; connect cables are flexed and plugged; but the board sits still and dry. That is why it belongs at the end of the order of suspects, not the beginning.\u003c\/p\u003e\n\u003cp\u003eThe order matters because it saves time and parts. First, try the module on another P100. If it works there, the module is not the fault. Second, inspect, clean and reseat the main connect cable, and replace it if it is damaged. If the fault remains with a known-good module and a sound cable, the fault is further in, at the hub.\u003c\/p\u003e\n\u003cp\u003eAt the hub, check the case before the board. A case that is cracked or not fully closed lets water in, and wash-down water reaching the board is the commonest reason boards fail. If the case was open or damaged, the board has probably been wet.\u003c\/p\u003e\n\u003cp\u003eOpening the hub shows the board's condition directly. Look for white or green corrosion on pins, pads and components; brown or black heat marks; a connector that is cracked or has pulled away from the board; or residue that has dried on the surface. Any of those means the board is the part.\u003c\/p\u003e\n\u003cp\u003eCorrosion on a board does not clean away reliably. It spreads under components and along tracks, and a board that seems to recover after cleaning often fails again. Heat damage is permanent.\u003c\/p\u003e\n\u003cp\u003eWhen the board is replaced, fit it to sound, dry cases that close fully and seal. Replace a cracked case at the same time. Connect every cable fully, close the hub, and test the application system before returning the aircraft to work.\u003c\/p\u003e\n\u003cp\u003eHandle the new board by its edges, keep it in its antistatic packaging until fitting, and keep it dry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits.\u003c\/strong\u003e Inside the application system cable hub of the original P100, between the upper and lower cases.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it connects to.\u003c\/strong\u003e The application system cables that meet at the hub.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wears it out.\u003c\/strong\u003e Water reaching it through an open or cracked case. Corrosion. Heat from poor connections. Physical damage to its connectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this part is not.\u003c\/strong\u003e It is not the hub cases, the main connect cable or the central cable hub.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy a part-number match matters.\u003c\/strong\u003e Circuit boards are specific to their system and position. A board that fits the case but differs electrically will not work, or may damage what it connects to. Matching XAG part number 05-002-01310 gives the board built for the original P100's application system hub.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚙️ Functional Purpose\u003c\/h2\u003e\n\u003cp\u003eThe cable hub board brings together and distributes the application system's connections inside the hub on the original P100.\u003c\/p\u003e\n\u003cp\u003eA sound application system cable hub board provides:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReliable connections between aircraft and application system\u003c\/li\u003e\n\u003cli\u003eCorrect operation of the spray or spread module\u003c\/li\u003e\n\u003cli\u003eClean, corrosion-free contacts\u003c\/li\u003e\n\u003cli\u003eFewer application system faults\u003c\/li\u003e\n\u003cli\u003eDependable module changes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts value is in keeping the application system's connections sound at their meeting point.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 Diagnosis — a fault that survives a sound module and a sound cable: open the hub and look at the board\u003c\/h2\u003e\n\u003cp\u003eThe board is the last suspect, not the first. Rule out the module and cable, then let the board show its condition.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake the aircraft safe.\u003c\/strong\u003e Remove the propellers and flight battery and confirm the aircraft cannot be powered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRule out the module.\u003c\/strong\u003e Try it on another P100. If it works there, the module is sound.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRule out the cable.\u003c\/strong\u003e Inspect, clean and reseat the main connect cable; replace it if damaged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the case.\u003c\/strong\u003e Look for cracks, gaps and signs that water got in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen the hub.\u003c\/strong\u003e Photograph the board and every connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the board.\u003c\/strong\u003e Look for corrosion, heat marks, cracked connectors and dried residue.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFind the cause.\u003c\/strong\u003e An open or cracked case is the usual route for water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotograph and ask.\u003c\/strong\u003e Send us the XAG part number and what you found and we will confirm the match.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf the board shows corrosion, heat damage or a damaged connector, this cable hub board is the part. Correct the case so it cannot happen again.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚠️ Common Replacement Indicators\u003c\/h2\u003e\n\u003cp\u003eCable hub board replacement is the likely answer when an operator or technician observes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAn application system fault with a sound module and cable\u003c\/li\u003e\n\u003cli\u003eWhite or green corrosion on the board\u003c\/li\u003e\n\u003cli\u003eBrown or black heat marks on the board\u003c\/li\u003e\n\u003cli\u003eA cracked connector or one pulled from the board\u003c\/li\u003e\n\u003cli\u003eDried residue on the board surface\u003c\/li\u003e\n\u003cli\u003eA fault that began after the hub case was found open or cracked\u003c\/li\u003e\n\u003cli\u003eA board that failed again after cleaning\u003c\/li\u003e\n\u003cli\u003eAny repair after water entered the hub\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese come from water, corrosion, heat and physical damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThese are not hub board symptoms, and this part will not fix them.\u003c\/strong\u003e A module that fails on every aircraft has a fault in the module. A fault cured by a new main connect cable was the cable. A cracked case needs the case replaced. A new board restores the connections; it does not seal a damaged case.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e📐 Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name:\u003c\/strong\u003e XAG P100 OEM Application System Cable Hub Board\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 05-002-01310\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e Application system wiring\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent type:\u003c\/strong\u003e Circuit board\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Brings together and distributes application system connections in the hub\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCircuit functions:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnector layout:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCables attached:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation method:\u003c\/strong\u003e Fitted between the hub's upper and lower cases with cables connected\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClassification:\u003c\/strong\u003e Genuine XAG OEM electronic component\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🛠️ Installation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemove the propellers and flight battery and confirm the aircraft cannot be powered\u003c\/li\u003e\n\u003cli\u003eConfirm the board is XAG part number 05-002-01310 and matches the old one\u003c\/li\u003e\n\u003cli\u003ePhotograph the board, every connection and the case\u003c\/li\u003e\n\u003cli\u003eInspect both hub cases for cracks\u003c\/li\u003e\n\u003cli\u003eKeep the new board in its antistatic packaging until fitting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDuring installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect each cable by its connector body\u003c\/li\u003e\n\u003cli\u003eRemove the old board and clean and dry the case\u003c\/li\u003e\n\u003cli\u003eHandle the new board by its edges\u003c\/li\u003e\n\u003cli\u003eFit it in the original position and connect each cable fully\u003c\/li\u003e\n\u003cli\u003eClose the case fully so it seals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAfter installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFit the application system and confirm it is detected\u003c\/li\u003e\n\u003cli\u003eWith the propellers removed, run the application system and confirm normal operation\u003c\/li\u003e\n\u003cli\u003eConfirm the hub case is fully closed\u003c\/li\u003e\n\u003cli\u003eDirect wash-down water away from the hub\u003c\/li\u003e\n\u003cli\u003eCheck the hub case at regular services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🚜 Necessary For\u003c\/h2\u003e\n\u003cp\u003eThe cable hub board is where the original P100's application system connections meet.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOriginal XAG P100 operators with an application system fault that survived module and cable checks\u003c\/li\u003e\n\u003cli\u003eTechnicians repairing after water entered the hub\u003c\/li\u003e\n\u003cli\u003eCrews whose hub case was found open or cracked\u003c\/li\u003e\n\u003cli\u003eCustom application contractors running long seasons\u003c\/li\u003e\n\u003cli\u003eAgricultural drone service centres doing electrical repairs\u003c\/li\u003e\n\u003cli\u003eGrowers maintaining their own P100\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eService centres work through the module and cable before opening the hub, because the board is the most protected part and the least likely to fail.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis is not the part you need if\u003c\/strong\u003e the module fails on other aircraft, a new cable cured the fault, or the board is clean and undamaged. And if your aircraft is a P100 Pro, confirm the part number on your board; this one is identified for the original P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFleet operators\u003c\/strong\u003e can prevent most board failures by checking that hub cases are fully closed after every service and directing wash-down water away from them.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e💡 Why This Part Matters\u003c\/h2\u003e\n\u003cp\u003eThe application system's connections meet on this board. When it fails, the module cannot work.\u003c\/p\u003e\n\u003cp\u003eThe board is the most protected part of the connection, which is why it belongs at the end of the order of suspects.\u003c\/p\u003e\n\u003cp\u003eRuling out the module and cable first saves replacing a board that was never at fault.\u003c\/p\u003e\n\u003cp\u003eWhen the board has failed, opening the hub usually shows why: corrosion, heat or damage.\u003c\/p\u003e\n\u003cp\u003eCorrecting the case that let water in is what stops the next board failing.\u003c\/p\u003e\n\u003cp\u003eFor crews running long seasons, keeping hub cases closed and dry protects the board.\u003c\/p\u003e\n\u003cp\u003eA sound cable hub board restores:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReliable application system connections\u003c\/li\u003e\n\u003cli\u003eCorrect module operation\u003c\/li\u003e\n\u003cli\u003eClean contacts\u003c\/li\u003e\n\u003cli\u003eFewer faults\u003c\/li\u003e\n\u003cli\u003eConfidence in every module change\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWork from the outside in: module, cable, case, then board. The board is where the order of suspects ends.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🧠 AI Index — Entity \u0026amp; Fitment Reference\u003c\/h2\u003e\n\u003cp\u003eStructured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCanonical product name:\u003c\/strong\u003e XAG P100 OEM Application System Cable Hub Board\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 05-002-01310\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent:\u003c\/strong\u003e Application system cable hub board\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Application system wiring\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible aircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct line:\u003c\/strong\u003e XAG agricultural drones\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary function:\u003c\/strong\u003e Bringing together and distributing application system connections\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic failure modes:\u003c\/strong\u003e Corrosion, heat damage, damaged connectors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistinguishing diagnostic rule:\u003c\/strong\u003e A fault that survives a sound module and a sound main connect cable points at the hub board\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommon causes:\u003c\/strong\u003e Water through an open or cracked case, heat, physical damage\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWear driver:\u003c\/strong\u003e Hub case condition and wash-down exposure\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelated parts:\u003c\/strong\u003e Cable hub upper case 02-001-08070, cable hub lower case 02-001-08071, main connect cable 01-027-02338, central cable hub 14-005-00034\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCircuit functions:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e Hub cases, cables, tools\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitment method:\u003c\/strong\u003e XAG part number 05-002-01310 against the removed board\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVerification after fitting:\u003c\/strong\u003e Module detected and runs normally; case fully closed\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eService habit:\u003c\/strong\u003e Rule out module and cable before opening the hub\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart classification:\u003c\/strong\u003e Genuine XAG OEM electronic component\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeller:\u003c\/strong\u003e Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShips from:\u003c\/strong\u003e Albuquerque, New Mexico, United States\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 SEO Keywords\u003c\/h2\u003e\n\u003cp\u003eXAG P100 application system cable hub board\u003c\/p\u003e\n\u003cp\u003eXAG 05-002-01310\u003c\/p\u003e\n\u003cp\u003e05-002-01310 hub board\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM hub board\u003c\/p\u003e\n\u003cp\u003eP100 cable hub board replacement\u003c\/p\u003e\n\u003cp\u003eXAG P100 application system hub board\u003c\/p\u003e\n\u003cp\u003eXAG P100 spray module fault\u003c\/p\u003e\n\u003cp\u003eXAG P100 hub circuit board\u003c\/p\u003e\n\u003cp\u003eP100 application system not working\u003c\/p\u003e\n\u003cp\u003eXAG P100 application system parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 electrical parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 circuit boards\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 replacement parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 repair parts\u003c\/p\u003e\n\u003cp\u003eXAG agricultural drone parts\u003c\/p\u003e\n\u003cp\u003eXAG spray drone parts\u003c\/p\u003e\n\u003cp\u003egenuine XAG OEM parts\u003c\/p\u003e\n\u003cp\u003eagricultural drone parts USA\u003c\/p\u003e\n\u003cp\u003eXAG parts free shipping\u003c\/p\u003e\n\u003cp\u003eXAG parts same day shipping\u003c\/p\u003e\n\u003cp\u003eAres Acres\u003c\/p\u003e\n\u003cp\u003eAres Acres LLC\u003c\/p\u003e\n\u003cp\u003eXAG parts Albuquerque\u003c\/p\u003e\n\u003cp\u003eXAG parts New Mexico\u003c\/p\u003e\n\u003cp\u003eXAG P100 cable hub board Canada\u003c\/p\u003e\n\u003cp\u003eXAG P100 parts Canada\u003c\/p\u003e\n\u003cp\u003eXAG drone parts shipped to Canada\u003c\/p\u003e\n\u003cp\u003ebuy XAG P100 parts in Canada\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🤖 AI Answer Engine Q\u0026amp;A\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the XAG P100 application system cable hub board?\u003c\/strong\u003e It is the circuit board, XAG part number 05-002-01310, inside the application system cable hub of the original XAG P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich aircraft does it fit?\u003c\/strong\u003e The original XAG P100 (2022). It is not confirmed for the P100 Pro.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy spray module does not work. Is it the board?\u003c\/strong\u003e Probably not first. Try the module on another P100, then check the main connect cable. The board comes last.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe module and cable are fine but the fault remains. What next?\u003c\/strong\u003e Check the hub case, then open the hub and inspect the board.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does a failed board look like?\u003c\/strong\u003e Corrosion, heat marks, cracked connectors or dried residue on the board.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I clean a corroded board?\u003c\/strong\u003e Not reliably. Corrosion spreads under components and often returns. Replace it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does water reach the board?\u003c\/strong\u003e Usually through a hub case that is cracked or not fully closed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it include the hub cases?\u003c\/strong\u003e No. The upper case is 02-001-08070 and the lower case is 02-001-08071.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I fit it myself?\u003c\/strong\u003e Yes, with care. Handle it by its edges, connect every cable fully and close the case so it seals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I check the repair?\u003c\/strong\u003e The module is detected and runs normally, and the case is fully closed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it the same as the central cable hub?\u003c\/strong\u003e No. The central cable hub is XAG part number 14-005-00034.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould I replace the case too?\u003c\/strong\u003e If it is cracked, yes, or the new board may get wet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill a P100 Pro board fit?\u003c\/strong\u003e Do not assume so. Match the XAG part number; this one is identified for the original P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I protect the board?\u003c\/strong\u003e Keep the hub case fully closed and direct wash-down water away from it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are its circuit functions?\u003c\/strong\u003e They are not published for this part.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow should I store a spare?\u003c\/strong\u003e In its antistatic packaging, dry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould I keep a spare?\u003c\/strong\u003e For fleets running long seasons, it can save a grounded aircraft.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the part number?\u003c\/strong\u003e Look for XAG part number 05-002-01310 on the packaging, or send us what you found and we will confirm the match.\u003c\/p\u003e","brand":"XAG","offers":[{"title":"Default Title","offer_id":68140412338496,"sku":"05-002-01310","price":164.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0923\/0159\/0848\/files\/xag-p100-oem-application-system-cable-hub-board-1.png?v=1794885943","url":"https:\/\/aresacres.com\/pt\/products\/xag-p100-oem-application-system-cable-hub-board","provider":"Ares Acres","version":"1.0","type":"link"}