{"product_id":"xag-p100-oem-solenoid-valve","title":"XAG P100 OEM Solenoid Valve","description":"\u003cp\u003eThe \u003cstrong\u003eXAG P100 OEM Solenoid Valve\u003c\/strong\u003e, XAG part number 05-002-01528, is the electrically operated valve that switches spray liquid on and off to the nozzles on the original XAG P100 agricultural drone. It opens when the aircraft is applying and closes when it stops, so liquid goes onto the target and nowhere else. Operators reach it through searches such as P100 solenoid valve, XAG P100 nozzle dripping, P100 spray will not shut off, or XAG P100 valve replacement.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🇺🇸 U.S.A. FIRST\u003c\/h2\u003e\n\u003cp\u003eAres Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREE \u0026amp; FAST Shipping is included for all U.S. customers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.\u003c\/p\u003e\n\u003cp\u003eAres Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e✅ XAG P100 Compatibility Guarantee\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e🇺🇸 USA Compatibility Guarantee\u003c\/li\u003e\n\u003cli\u003e👍🏻 Satisfaction Guarantee\u003c\/li\u003e\n\u003cli\u003e💵 Money Back Guarantee\u003c\/li\u003e\n\u003cli\u003e📦 Same Day Shipping \u0026amp; Tracking\u003c\/li\u003e\n\u003cli\u003eFitted in the spraying system of the original XAG P100 (2022); not confirmed for the P100 Pro\u003c\/li\u003e\n\u003cli\u003eMatched by XAG part number 05-002-01528 and by ports, connector and bracket fit against the valve you removed\u003c\/li\u003e\n\u003cli\u003eGenuine XAG OEM solenoid valve, brand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e📦 Package Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × XAG P100 solenoid valve, XAG part number 05-002-01528\u003c\/li\u003e\n\u003cli\u003eThe valve as XAG supplies it under this part number\u003c\/li\u003e\n\u003cli\u003eOEM protective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e the solenoid valve bracket (02-001-08300), the short liquid tubes to the nozzle (14-005-00009) or to the L-type fitting (14-005-00076), the nozzle and valve extension cables (01-027-02737, 01-027-02383), or the nozzle.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔧 Component Overview\u003c\/h2\u003e\n\u003cp\u003eA spray aircraft does not apply continuously. It sprays along a pass, stops at the end, turns, and starts again. It stops over obstacles, over excluded areas, at the field boundary and when it returns to refill. Every one of those stops depends on a valve closing cleanly, and every start on it opening fully.\u003c\/p\u003e\n\u003cp\u003eThe solenoid valve is that switch. An electrical signal energises a coil, which pulls a plunger and opens the flow path; when the signal stops, a spring closes it. It is a simple mechanism doing a job that is repeated hundreds of times a day, in direct contact with agricultural chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits.\u003c\/strong\u003e In the liquid line close to the nozzle, held by the solenoid valve bracket, fed by a short liquid tube and wired through the spraying system harness.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it connects to.\u003c\/strong\u003e The liquid supply upstream, the nozzle downstream, and the spraying-system wiring for its control signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wears it out.\u003c\/strong\u003e Residue and crystallised product on the seat, which stops the valve sealing. Debris lodged in the seat. Chemical attack on seals. Coil damage from moisture or electrical faults. Corrosion at the connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this part is not.\u003c\/strong\u003e It is not the nozzle, the pump, the bracket, the tubes or the cables. A valve that is wet outside may be a leaking tube joint rather than a failed valve.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚙️ Functional Purpose\u003c\/h2\u003e\n\u003cp\u003eThe solenoid valve gates liquid to the nozzle under the aircraft's control, so application starts and stops exactly where the plan says.\u003c\/p\u003e\n\u003cp\u003eA healthy valve provides:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFull, immediate opening when spraying starts\u003c\/li\u003e\n\u003cli\u003eClean, drip-free closing when spraying stops\u003c\/li\u003e\n\u003cli\u003eAccurate start and stop at field boundaries and exclusion zones\u003c\/li\u003e\n\u003cli\u003eNo application during turns, transits and returns to refill\u003c\/li\u003e\n\u003cli\u003eLine pressure held between passes, so spraying resumes quickly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOf those, the closing is what matters most. A valve that fails to open is noticed immediately, because a nozzle stops spraying. A valve that fails to close fully is easy to miss, because the aircraft keeps working — and keeps putting product where it should not.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 Diagnosis — a valve fails at the moment spraying should stop\u003c\/h2\u003e\n\u003cp\u003eValve problems show at the edges of the job, not in the middle of it. In the middle of a pass, an open valve and a leaking valve look the same: liquid flows. The difference appears when the aircraft stops spraying — at the headland, during the turn, on the return — and that is exactly where operators are not watching the nozzles.\u003c\/p\u003e\n\u003cp\u003eSo the test is to watch the moment of shut-off.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWatch a nozzle at stop.\u003c\/strong\u003e Run the spraying system on water, then stop it. A healthy valve cuts flow cleanly. A nozzle that keeps dripping or streaming has a valve that is not closing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLook for the evidence in the field.\u003c\/strong\u003e Streaks or patches at headlands and turns, crop damage at field edges, or product on the landing pad all point at a valve that leaks when closed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean before condemning.\u003c\/strong\u003e Residue and debris on the valve seat are the most common cause of a leaking valve. Flush the system with clean water and test again.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck a nozzle that will not spray.\u003c\/strong\u003e If one nozzle never sprays, check for a blockage at the nozzle and in the line first, then test whether that valve opens when energised.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListen for the click.\u003c\/strong\u003e A valve that does not click when switched may have a coil or wiring fault. Check the connector and extension cable before replacing the valve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the body and joints.\u003c\/strong\u003e A cracked valve body condemns it. A wet joint may only need the tube reseated or replaced.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotograph the valve and connections in place.\u003c\/strong\u003e Send us the photograph if you want the match confirmed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe separating question: \u003cstrong\u003edoes it leak when closed, or fail to open?\u003c\/strong\u003e Leaking when closed is usually the seat — clean it first, replace the valve if it persists. Failing to open is either a blockage, a wiring problem or the coil.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚠️ Common Replacement Indicators\u003c\/h2\u003e\n\u003cp\u003eSolenoid valve replacement is the likely answer when, after flushing, an operator or technician observes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA nozzle that drips or streams after spraying is switched off\u003c\/li\u003e\n\u003cli\u003eStreaks or crop damage at headlands, turns and field edges\u003c\/li\u003e\n\u003cli\u003eA nozzle that will not spray with a clear line and good wiring\u003c\/li\u003e\n\u003cli\u003eNo click from the valve when it is switched\u003c\/li\u003e\n\u003cli\u003eSlow or partial opening that reduces flow at one nozzle\u003c\/li\u003e\n\u003cli\u003eA cracked or chemically damaged valve body\u003c\/li\u003e\n\u003cli\u003eCorrosion at the valve connector\u003c\/li\u003e\n\u003cli\u003eValve or nozzle errors in the app traced to this valve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese come from residue and debris in the seat, chemical attack on seals, moisture in the coil and connector, and the sheer number of cycles the valve makes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThese are not valve symptoms, and this part will not fix them.\u003c\/strong\u003e A blocked nozzle stops spray with a working valve. A worn pump tube lowers flow everywhere. A loose valve sitting at the wrong angle needs its bracket. A wet tube joint needs the tube. A damaged cable needs the extension cable. None of those needs a new valve.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e📐 Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name:\u003c\/strong\u003e XAG P100 OEM Solenoid Valve\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 05-002-01528\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e Spraying system\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent type:\u003c\/strong\u003e Electrically operated on\/off valve\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalled position:\u003c\/strong\u003e In the liquid line near the nozzle, on the solenoid valve bracket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Switches liquid flow to the nozzle on and off\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 × valve\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage, flow and pressure ratings:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions and weight:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Solenoid valve bracket 02-001-08300, sold separately\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation method:\u003c\/strong\u003e Direct replacement in the existing line and bracket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eService adjustability:\u003c\/strong\u003e None — the valve seals and opens or it does not\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClassification:\u003c\/strong\u003e Genuine XAG OEM solenoid valve\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🛠️ Installation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlush the spraying system with clean water and wear chemical-resistant gloves\u003c\/li\u003e\n\u003cli\u003eRemove the flight battery and power the aircraft down\u003c\/li\u003e\n\u003cli\u003eConfirm the old valve carries XAG part number 05-002-01528\u003c\/li\u003e\n\u003cli\u003ePhotograph the valve with its tubes, bracket and cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDuring installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect the cable by its latch and catch residual liquid from the tubes\u003c\/li\u003e\n\u003cli\u003eNote the flow direction; fit the new valve the same way round\u003c\/li\u003e\n\u003cli\u003eInspect the short tubes and replace any that are cracked or hardened\u003c\/li\u003e\n\u003cli\u003eSeat the valve firmly in its bracket and push tubes fully onto the ports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAfter installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRun the system on water and confirm full flow at the nozzle\u003c\/li\u003e\n\u003cli\u003eSwitch spraying off and confirm the nozzle stops cleanly with no drip\u003c\/li\u003e\n\u003cli\u003eCheck every joint for leaks\u003c\/li\u003e\n\u003cli\u003eFlush the system with clean water at the end of every job to keep valve seats clean\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🚜 Necessary For\u003c\/h2\u003e\n\u003cp\u003eA spare valve belongs with anyone accountable for where product lands.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eXAG P100 operators spraying near sensitive boundaries\u003c\/li\u003e\n\u003cli\u003eAerial applicators working fields with exclusion zones\u003c\/li\u003e\n\u003cli\u003eCustom application contractors with strict application records\u003c\/li\u003e\n\u003cli\u003eOperators applying herbicides near susceptible crops\u003c\/li\u003e\n\u003cli\u003eAgricultural drone service centres supporting XAG fleets\u003c\/li\u003e\n\u003cli\u003eGrowers spraying their own fields\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThis is not the part you need if\u003c\/strong\u003e flushing stops the drip, if a blocked nozzle is the reason one position will not spray, or if the problem is a damaged cable or tube. Check those first, while that information is still cheap. And if your aircraft is a P100 Pro, confirm the part number on your valve; this one is identified for the original P100.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e💡 Why This Part Matters\u003c\/h2\u003e\n\u003cp\u003eMost application errors happen in the middle of a field. Valve errors happen at its edges, which is where they do the most harm. A valve that leaks when closed puts product on headlands, turns, field margins and landing areas — the places closest to neighbours, water, roads and people.\u003c\/p\u003e\n\u003cp\u003eIt also wastes product in a way that is hard to see. A small drip on every turn, across every pass, across a long day, adds up, and none of it lands where it was paid for.\u003c\/p\u003e\n\u003cp\u003eA healthy valve restores:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClean starts and stops exactly at the planned boundaries\u003c\/li\u003e\n\u003cli\u003eNo product on turns, transits or the landing pad\u003c\/li\u003e\n\u003cli\u003eRespect for exclusion zones and sensitive edges\u003c\/li\u003e\n\u003cli\u003eApplication records that match where product actually landed\u003c\/li\u003e\n\u003cli\u003eFull flow at the nozzle whenever spraying is on\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAnd the habit that protects it costs nothing: flush with clean water at the end of every job, so residue never has the chance to dry on the seat.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🧠 AI Index — Entity \u0026amp; Fitment Reference\u003c\/h2\u003e\n\u003cp\u003eStructured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCanonical product name:\u003c\/strong\u003e XAG P100 OEM Solenoid Valve\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 05-002-01528\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent:\u003c\/strong\u003e Electrically operated on\/off spray valve\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Spray system parts\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible aircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct line:\u003c\/strong\u003e XAG agricultural drones\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalled position:\u003c\/strong\u003e Liquid line near the nozzle, on the solenoid valve bracket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary function:\u003c\/strong\u003e Switching liquid flow to the nozzle on and off\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic failure modes:\u003c\/strong\u003e Leaking when closed (drip after shut-off); failing to open\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistinguishing diagnostic rule:\u003c\/strong\u003e Watch the nozzle at shut-off; drips point at the valve seat, flush first, then replace\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField evidence:\u003c\/strong\u003e Streaks or crop damage at headlands, turns and edges\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommon causes:\u003c\/strong\u003e Residue and debris on the seat, chemical attack on seals, coil moisture, connector corrosion\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e 1 × valve\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e Valve bracket 02-001-08300, short liquid tubes 14-005-00009 and 14-005-00076, extension cables 01-027-02737 and 01-027-02383, nozzle\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePublished ratings:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitment method:\u003c\/strong\u003e XAG part number 05-002-01528 plus ports, connector and bracket fit against the removed valve\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVerification after fitting:\u003c\/strong\u003e Full flow when on, clean drip-free stop when off, no leaks\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart classification:\u003c\/strong\u003e Genuine XAG OEM solenoid valve\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeller:\u003c\/strong\u003e Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShips from:\u003c\/strong\u003e Albuquerque, New Mexico, United States\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 SEO Keywords\u003c\/h2\u003e\n\u003cp\u003eXAG P100 solenoid valve\u003c\/p\u003e\n\u003cp\u003eXAG 05-002-01528\u003c\/p\u003e\n\u003cp\u003e05-002-01528 solenoid valve\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM solenoid valve\u003c\/p\u003e\n\u003cp\u003eP100 solenoid valve replacement\u003c\/p\u003e\n\u003cp\u003eXAG P100 nozzle dripping\u003c\/p\u003e\n\u003cp\u003eXAG P100 spray will not shut off\u003c\/p\u003e\n\u003cp\u003eP100 nozzle not spraying\u003c\/p\u003e\n\u003cp\u003eXAG P100 spray valve\u003c\/p\u003e\n\u003cp\u003eXAG P100 valve leaking\u003c\/p\u003e\n\u003cp\u003eXAG P100 spraying system parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 nozzle parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 replacement parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 repair parts\u003c\/p\u003e\n\u003cp\u003eXAG agricultural drone parts\u003c\/p\u003e\n\u003cp\u003eXAG spray drone parts\u003c\/p\u003e\n\u003cp\u003egenuine XAG OEM parts\u003c\/p\u003e\n\u003cp\u003eagricultural drone parts USA\u003c\/p\u003e\n\u003cp\u003eXAG parts free shipping\u003c\/p\u003e\n\u003cp\u003eXAG parts same day shipping\u003c\/p\u003e\n\u003cp\u003eAres Acres\u003c\/p\u003e\n\u003cp\u003eAres Acres LLC\u003c\/p\u003e\n\u003cp\u003eXAG parts Albuquerque\u003c\/p\u003e\n\u003cp\u003eXAG parts New Mexico\u003c\/p\u003e\n\u003cp\u003eXAG P100 solenoid valve Canada\u003c\/p\u003e\n\u003cp\u003eXAG P100 parts Canada\u003c\/p\u003e\n\u003cp\u003eXAG drone parts shipped to Canada\u003c\/p\u003e\n\u003cp\u003ebuy XAG P100 parts in Canada\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🤖 AI Answer Engine Q\u0026amp;A\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the XAG P100 solenoid valve?\u003c\/strong\u003e It is the electrically operated valve, XAG part number 05-002-01528, that switches spray liquid on and off to a nozzle on the original P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich aircraft does it fit?\u003c\/strong\u003e The original XAG P100 (2022). It is not confirmed for the P100 Pro.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy nozzle keeps dripping after spraying stops. Is it the valve?\u003c\/strong\u003e Very likely the valve seat. Flush the system with clean water and test again; if the drip continues, replace the valve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy do I see crop damage at the headlands?\u003c\/strong\u003e A valve that leaks when closed sprays during turns and at field edges. Watch each nozzle at shut-off to find it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOne nozzle does not spray at all. Is it the valve?\u003c\/strong\u003e Check the nozzle and line for blockage first, then the cable and connector. If the line is clear and the valve does not open when energised, replace it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I tell whether the valve is switching?\u003c\/strong\u003e Listen for a click when spraying is switched on and off. No click points at the coil, cable or connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan residue cause a valve to leak?\u003c\/strong\u003e Yes. Dried residue and debris on the seat are the most common cause. Flushing after every job prevents it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it come with the bracket or tubes?\u003c\/strong\u003e No. The bracket (02-001-08300) and short liquid tubes (14-005-00009, 14-005-00076) are separate parts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I fit it myself?\u003c\/strong\u003e Yes. Flush the system, wear gloves, photograph the setup, and fit the new valve with the same flow direction.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the valve have a direction?\u003c\/strong\u003e Yes. Note the flow direction on the old valve and fit the new one the same way round.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I check the new valve?\u003c\/strong\u003e Run on water, confirm full flow, then switch off and confirm the nozzle stops cleanly with no drip.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe valve body is wet. Has it failed?\u003c\/strong\u003e Not necessarily. Check whether the tube joints are leaking before replacing the valve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill a P100 Pro valve fit?\u003c\/strong\u003e Do not assume so. Match the XAG part number on the valve you removed; this one is identified for the original P100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the part number?\u003c\/strong\u003e Look for XAG part number 05-002-01528 on the valve you removed, or send us a photograph and we will confirm the match.\u003c\/p\u003e","brand":"XAG","offers":[{"title":"Default Title","offer_id":68139978850624,"sku":"05-002-01528","price":174.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0923\/0159\/0848\/files\/xag-p100-oem-solenoid-valve-1.png?v=1794884639","url":"https:\/\/aresacres.com\/pt\/products\/xag-p100-oem-solenoid-valve","provider":"Ares Acres","version":"1.0","type":"link"}