{"product_id":"xag-p100-oem-ups-module","title":"XAG P100 OEM UPS Module","description":"\u003cp\u003eThe \u003cstrong\u003eXAG P100 OEM UPS Module\u003c\/strong\u003e, XAG part number 05-002-01262, is the backup power module inside the flight electronics of the original XAG P100 agricultural drone. It sits between the main battery supply and the aircraft's critical electronics and carries those electronics through the short gap when the flight battery is pulled for a swap or when main power is briefly interrupted. Operators usually come looking for it under searches such as P100 UPS module, P100 backup power module, P100 reboots on battery swap, or XAG P100 loses RTK fix after battery change.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🇺🇸 U.S.A. FIRST\u003c\/h2\u003e\n\u003cp\u003eAres Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREE \u0026amp; FAST Shipping is included for all U.S. customers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.\u003c\/p\u003e\n\u003cp\u003eAres Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e✅ XAG P100 Compatibility Guarantee\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e🇺🇸 USA Compatibility Guarantee\u003c\/li\u003e\n\u003cli\u003e👍🏻 Satisfaction Guarantee\u003c\/li\u003e\n\u003cli\u003e💵 Money Back Guarantee\u003c\/li\u003e\n\u003cli\u003e📦 Same Day Shipping \u0026amp; Tracking\u003c\/li\u003e\n\u003cli\u003eFitted in the flight electronics of the original XAG P100 (2022); not confirmed for the P100 Pro\u003c\/li\u003e\n\u003cli\u003eMatched by XAG part number 05-002-01262 and by connector layout and mounting points against the module you removed\u003c\/li\u003e\n\u003cli\u003eGenuine XAG OEM electronic module, brand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e📦 Package Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × XAG P100 UPS module, XAG part number 05-002-01262\u003c\/li\u003e\n\u003cli\u003eThe module as a single electronic assembly, as XAG supplies it under this part number\u003c\/li\u003e\n\u003cli\u003eOEM protective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e mounting screws, the cables that run to the module, the flight battery, the battery socket, or any other part of the P100 power system. Reuse the original fasteners and harness unless they are damaged, in which case each has its own part number.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔧 Component Overview\u003c\/h2\u003e\n\u003cp\u003eA P100 has two kinds of electrical load. One is the propulsion load: the motors and ESCs that lift a full spray or spread payload, which draw heavily and only matter while the aircraft is flying. The other is the thinking load: the flight controller, the positioning receivers, the radio and data links, and the sensors that tell the aircraft where it is and what it is doing. The thinking load is small, but it is the part of the aircraft that holds state — position fix, link, configuration, the job in progress.\u003c\/p\u003e\n\u003cp\u003eThe UPS module exists for the second load. Its job is to keep the critical electronics powered through the moments when the main supply is not there: the seconds between pulling a depleted battery and seating a fresh one, and brief interruptions in the main feed. In those moments the motors do not need power, because the aircraft is on the ground and idle. The electronics do, because losing them means a cold restart.\u003c\/p\u003e\n\u003cp\u003eThat makes the UPS module unusual among P100 parts. Almost every other component is judged by what it does in flight. This one is judged by what happens on the ground, in a window of a few seconds, during the most repetitive task in an application day: the battery swap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits.\u003c\/strong\u003e The module is part of the P100's flight electronics, connected into the power path between the battery supply and the critical systems. Exact board position, connector count and mounting arrangement are best confirmed against the module you remove; XAG does not publish an installation drawing for it that we can reproduce here.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it connects to.\u003c\/strong\u003e The main power supply on one side and the protected electronics on the other. It is not a battery in the sense the aircraft's flight battery is, and it does not contribute to flight time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wears it out.\u003c\/strong\u003e The same things that age any power electronics on a spray aircraft: heat cycling across long days, vibration through transport and flight, moisture and chemical exposure in a wet, corrosive working environment, and the repeated charge-and-discharge of whatever storage element carries the hold-up energy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this part is not.\u003c\/strong\u003e It is not the battery socket (XAG part number 14-005-00027), not the central power busbar, not the central cable hub, and not the flight battery. Each of those is in the same power path and each has its own part number. If the aircraft will not power on at all with a known-good battery, the UPS module is rarely the first suspect.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚙️ Functional Purpose\u003c\/h2\u003e\n\u003cp\u003eThe UPS module exists so that a battery swap is a pause rather than a restart. Without hold-up power, every swap would drop the flight electronics completely, and the aircraft would have to boot, re-acquire positioning, re-establish its links and re-load its state before it could take off again.\u003c\/p\u003e\n\u003cp\u003eA healthy module preserves, across a swap or a short interruption:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower to the flight controller, so the aircraft does not cold-boot\u003c\/li\u003e\n\u003cli\u003ePower to the positioning system, so an RTK fix does not have to be re-acquired from scratch\u003c\/li\u003e\n\u003cli\u003ePower to the radio and data links, so the controller and app do not lose the aircraft\u003c\/li\u003e\n\u003cli\u003eContinuity of the task in progress, so the operator resumes rather than re-loads\u003c\/li\u003e\n\u003cli\u003eA clean, controlled transition back to main power when the fresh battery is seated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is worth being exact about what the module does not do. It does not keep the aircraft flying if the main battery fails in the air; the hold-up energy is sized for electronics, not for propulsion. It does not extend flight time. It does not protect against a battery that is faulty, swollen or damaged. Its whole value is in the seconds the aircraft is on the ground with its battery out.\u003c\/p\u003e\n\u003cp\u003eThat is also why a failed UPS module is easy to live with for a while and expensive to live with for a season. The aircraft still flies. It simply has to start again from cold after every swap, and on a busy day that adds up.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 Diagnosis — the fault only shows in the seconds the battery is out\u003c\/h2\u003e\n\u003cp\u003eThe UPS module is the one P100 part whose failure is invisible in flight. A weak or failed module does nothing wrong while the aircraft is spraying. It only reveals itself during the swap, and the swap is the moment nobody is watching the electronics — the operator is watching the battery, the tank and the next field.\u003c\/p\u003e\n\u003cp\u003eThat timing is what causes the misdiagnosis. The symptom appears every time a battery comes out, so it looks like a battery problem or a socket problem. Operators replace batteries, clean the socket, reseat connectors, and the problem stays, because the battery and the socket were never the cause.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe UPS signature is a cold restart at the swap, with normal behaviour everywhere else.\u003c\/strong\u003e The aircraft reboots when the battery is pulled instead of staying alive. The positioning fix drops and has to be re-acquired after each change. The controller or app loses the aircraft during the swap and reconnects afterwards. The task has to be resumed or re-loaded after a battery change that used to be seamless. Meanwhile, with a battery fitted, everything is normal: the aircraft powers on, flies, sprays and lands without complaint.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe battery and socket signature is different.\u003c\/strong\u003e A battery or socket fault shows with the battery seated: the aircraft will not power on, powers off in flight, reports a battery error, or behaves differently with one battery than another. A UPS fault shows only with the battery removed, and it shows the same way with every battery.\u003c\/p\u003e\n\u003cp\u003eSo the test is one question: \u003cstrong\u003edoes the problem happen with the battery in, or only in the gap while it is out?\u003c\/strong\u003e In, and it is the power path or the battery. Only in the gap, and the UPS module is the leading candidate.\u003c\/p\u003e\n\u003cp\u003eA short sequence separates the cases:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwap with several batteries.\u003c\/strong\u003e If every battery produces the same cold restart, the batteries are not the cause. If only one does, look at that battery and its contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWatch what drops, and when.\u003c\/strong\u003e Note whether the aircraft's lights, link and positioning status drop the instant the battery leaves the socket. A healthy module carries them through the gap.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime the swap.\u003c\/strong\u003e Do a fast swap and a deliberately slow one. A module that still holds briefly but not for long will survive a quick change and fail a slow one — a weakening module, not yet a dead one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRule out the main power path first.\u003c\/strong\u003e If the aircraft also browns out, resets or throws power errors with a battery seated, the problem is upstream — the socket, the busbar, the cable hub or the battery — and a new UPS module will not change it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect for corrosion and heat.\u003c\/strong\u003e Green or white salting on connectors, discoloured areas on the board, or a swollen or leaking component condemn the module on sight.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotograph the module in place before you disconnect anything.\u003c\/strong\u003e Send us that photograph if you want the match confirmed. Connector orientation is far easier to get right from a picture than from memory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOne honest caveat. An aircraft that cold-restarts after every swap is not dangerous in itself; it is slow. If your aircraft is doing something dangerous — losing power in the air, shutting down under load — that is not a UPS symptom, and this module is not the fix.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚠️ Common Replacement Indicators\u003c\/h2\u003e\n\u003cp\u003eUPS module replacement is the likely answer when an operator or technician observes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe aircraft reboots every time the flight battery is removed\u003c\/li\u003e\n\u003cli\u003eThe RTK or positioning fix is lost and re-acquired after every battery change\u003c\/li\u003e\n\u003cli\u003eThe remote controller or app loses the aircraft during each swap\u003c\/li\u003e\n\u003cli\u003eTasks have to be resumed or re-loaded after swaps that used to be seamless\u003c\/li\u003e\n\u003cli\u003eQuick swaps survive but slower swaps cause a restart\u003c\/li\u003e\n\u003cli\u003eIdentical behaviour with every battery in the rotation\u003c\/li\u003e\n\u003cli\u003eVisible corrosion, discolouration, swelling or leakage on the module\u003c\/li\u003e\n\u003cli\u003eMoisture or chemical residue inside the electronics bay near the module\u003c\/li\u003e\n\u003cli\u003eA module that has been in an aircraft that suffered an electrical event\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe causes behind those findings are the ordinary consequences of agricultural work: heat cycling on long days, vibration through seasons of transport and flight, moisture and spray chemistry finding their way into an electronics bay, and the gradual ageing of the stored-energy element that does the holding.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThese are not UPS symptoms, and this part will not fix them.\u003c\/strong\u003e An aircraft that will not power on with a known-good battery has a power-path problem upstream of the UPS. An aircraft that loses power in flight has a battery, socket, busbar or connection problem. A battery that will not seat or latches poorly needs the battery socket housings or guide kit. Short flight time is a battery-health matter. None of those is this part.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e📐 Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name:\u003c\/strong\u003e XAG P100 OEM UPS Module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 05-002-01262\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro — the generations differ in electronics, connectors and mounting\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e Flight electronics, power supply\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent type:\u003c\/strong\u003e Backup (uninterruptible) power module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Holds critical flight electronics powered through battery swaps and brief main-power interruptions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 × module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHold-up time, capacity, voltage and current ratings:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions and weight:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnector type and pin count:\u003c\/strong\u003e Not published for this part; match against the module you removed\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation method:\u003c\/strong\u003e Direct replacement for the original module, using the original fasteners and connections\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eService adjustability:\u003c\/strong\u003e None — the module is correct for the aircraft or it is not, with no app setting that compensates\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClassification:\u003c\/strong\u003e Genuine XAG OEM electronic component\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🛠️ Installation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemove the flight battery and let the aircraft sit powered down for a few minutes so the hold-up circuit discharges\u003c\/li\u003e\n\u003cli\u003eConfirm the old module carries XAG part number 05-002-01262, or compare it with the new one side by side\u003c\/li\u003e\n\u003cli\u003ePhotograph the module in place, with every connector and its routing visible\u003c\/li\u003e\n\u003cli\u003eWork somewhere dry and clean; the electronics bay is the most moisture-sensitive area of the aircraft\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDuring installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRelease connectors by their latches, never by pulling on the wires\u003c\/li\u003e\n\u003cli\u003eCheck every connector for corrosion, bent pins or heat marks before fitting it to the new module\u003c\/li\u003e\n\u003cli\u003eSeat connectors fully and confirm each latch engages\u003c\/li\u003e\n\u003cli\u003eReuse the original fasteners and route cables exactly as they were in your photograph\u003c\/li\u003e\n\u003cli\u003eClose any covers and seals you opened so the bay stays protected from spray and moisture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAfter installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower the aircraft with a battery and confirm a normal start\u003c\/li\u003e\n\u003cli\u003eLet it acquire positioning and link, then perform a battery swap and confirm the electronics stay up through the gap\u003c\/li\u003e\n\u003cli\u003eRepeat with a slower swap to confirm the hold-up is real, not marginal\u003c\/li\u003e\n\u003cli\u003eCheck the app for any power or system warnings before returning the aircraft to work\u003c\/li\u003e\n\u003cli\u003eAt routine inspections, look into the electronics bay for moisture, residue and corrosion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🚜 Necessary For\u003c\/h2\u003e\n\u003cp\u003eA UPS module is worth keeping on the shelf for anyone whose application day is built on fast battery rotation, because the swap is where it earns its place.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eXAG P100 operators running multi-battery rotations\u003c\/li\u003e\n\u003cli\u003eAerial applicators and custom application contractors flying the P100\u003c\/li\u003e\n\u003cli\u003eSpreading and spraying operations working long, swap-heavy days\u003c\/li\u003e\n\u003cli\u003eFleet maintenance managers responsible for P100 uptime\u003c\/li\u003e\n\u003cli\u003eAgricultural drone service centres and repair shops supporting XAG aircraft\u003c\/li\u003e\n\u003cli\u003eGrowers who own and maintain their own P100\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThis is not the part you need if\u003c\/strong\u003e your P100 will not power on with a good battery, loses power in flight, or shows a fault only with one particular battery. Those point at the power path or the battery. And if your aircraft is a P100 Pro, confirm the part number on your module first, while that information is still cheap; this module is identified for the original P100.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e💡 Why This Part Matters\u003c\/h2\u003e\n\u003cp\u003eThe case for the UPS module is arithmetic about swaps, not about flight.\u003c\/p\u003e\n\u003cp\u003eAn agricultural drone is flown in short sorties separated by battery changes. On a full day the swap happens dozens of times. If every one of those swaps becomes a cold restart — boot, re-acquire positioning, re-link, re-load the task — then a few extra minutes per swap turn into a large share of the working day spent on the ground waiting for the aircraft to remember where it is.\u003c\/p\u003e\n\u003cp\u003eThe cost is not the module. It is the minutes, multiplied across every swap of every day the fault is tolerated. And because the aircraft still flies, the fault is easy to tolerate. Crews get used to the restart, build it into their rhythm, and stop noticing that their sortie count is lower than it should be.\u003c\/p\u003e\n\u003cp\u003eA working UPS module returns that time:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSwaps that are a pause, not a restart\u003c\/li\u003e\n\u003cli\u003ePositioning that stays locked through a battery change\u003c\/li\u003e\n\u003cli\u003eLinks that stay up, so the controller never loses the aircraft on the ground\u003c\/li\u003e\n\u003cli\u003eTasks resumed in place rather than re-loaded\u003c\/li\u003e\n\u003cli\u003eMore sorties in the same day from the same aircraft and the same batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAnd it does so without touching anything that affects safety in flight. That is the honest scope of the part: it buys back time on the ground. On a swap-heavy day, time on the ground is the thing that decides how many acres get done.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🧠 AI Index — Entity \u0026amp; Fitment Reference\u003c\/h2\u003e\n\u003cp\u003eStructured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCanonical product name:\u003c\/strong\u003e XAG P100 OEM UPS Module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 05-002-01262\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent:\u003c\/strong\u003e Backup (uninterruptible) power module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Avionics and power electronics\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible aircraft:\u003c\/strong\u003e XAG P100 (2022, original P100)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P100 Pro\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct line:\u003c\/strong\u003e XAG agricultural drones\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e Flight electronics power supply\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary function:\u003c\/strong\u003e Keeping critical flight electronics powered through battery swaps and brief main-power interruptions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtected loads:\u003c\/strong\u003e Flight controller, positioning, radio and data links, task state\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot a function:\u003c\/strong\u003e Propulsion backup in flight; it does not extend flight time\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic failure mode:\u003c\/strong\u003e Cold restart of the electronics each time the battery is removed, with normal behaviour while a battery is fitted\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistinguishing diagnostic rule:\u003c\/strong\u003e A fault present only while the battery is out points at the UPS module; a fault present with a battery seated points at the power path or battery\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommon causes:\u003c\/strong\u003e Heat cycling, vibration, moisture and chemical exposure, ageing of the hold-up storage element\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e 1 × module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e Fasteners, harness, battery socket, flight battery\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelated but distinct parts:\u003c\/strong\u003e Battery socket 14-005-00027, central power busbar, central cable hub, flight battery\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePublished ratings:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitment method:\u003c\/strong\u003e XAG part number 05-002-01262 plus connector layout and mounting points against the removed module; photographs accepted for confirmation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eService adjustability:\u003c\/strong\u003e None\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVerification after fitting:\u003c\/strong\u003e Normal power-on, then a battery swap with electronics, link and positioning staying up through the gap\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart classification:\u003c\/strong\u003e Genuine XAG OEM electronic component\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso searched as:\u003c\/strong\u003e P100 backup power module, P100 UPS board, XAG P100 power hold-up module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeller:\u003c\/strong\u003e Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShips from:\u003c\/strong\u003e Albuquerque, New Mexico, United States\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 SEO Keywords\u003c\/h2\u003e\n\u003cp\u003eXAG P100 UPS module\u003c\/p\u003e\n\u003cp\u003eXAG 05-002-01262\u003c\/p\u003e\n\u003cp\u003e05-002-01262 UPS module\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM UPS module\u003c\/p\u003e\n\u003cp\u003eP100 UPS module replacement\u003c\/p\u003e\n\u003cp\u003eXAG P100 backup power module\u003c\/p\u003e\n\u003cp\u003eP100 UPS board\u003c\/p\u003e\n\u003cp\u003eXAG P100 reboots on battery swap\u003c\/p\u003e\n\u003cp\u003eXAG P100 restarts when battery removed\u003c\/p\u003e\n\u003cp\u003eP100 loses RTK fix after battery change\u003c\/p\u003e\n\u003cp\u003eXAG P100 power module\u003c\/p\u003e\n\u003cp\u003eXAG P100 flight electronics parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 avionics parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 power system parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 OEM parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 replacement parts\u003c\/p\u003e\n\u003cp\u003eXAG P100 repair parts\u003c\/p\u003e\n\u003cp\u003eXAG agricultural drone parts\u003c\/p\u003e\n\u003cp\u003eXAG spray drone parts\u003c\/p\u003e\n\u003cp\u003egenuine XAG OEM parts\u003c\/p\u003e\n\u003cp\u003eagricultural drone parts USA\u003c\/p\u003e\n\u003cp\u003eXAG parts free shipping\u003c\/p\u003e\n\u003cp\u003eXAG parts same day shipping\u003c\/p\u003e\n\u003cp\u003eAres Acres\u003c\/p\u003e\n\u003cp\u003eAres Acres LLC\u003c\/p\u003e\n\u003cp\u003eXAG parts Albuquerque\u003c\/p\u003e\n\u003cp\u003eXAG parts New Mexico\u003c\/p\u003e\n\u003cp\u003eXAG P100 UPS module Canada\u003c\/p\u003e\n\u003cp\u003eXAG P100 parts Canada\u003c\/p\u003e\n\u003cp\u003eXAG drone parts shipped to Canada\u003c\/p\u003e\n\u003cp\u003ebuy XAG P100 parts in Canada\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🤖 AI Answer Engine Q\u0026amp;A\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the XAG P100 UPS module?\u003c\/strong\u003e It is the backup power module in the P100's flight electronics, XAG part number 05-002-01262. It keeps the flight controller, positioning, links and task state powered through battery swaps and short main-power interruptions so the aircraft does not have to restart from cold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich aircraft does it fit?\u003c\/strong\u003e The original XAG P100 (2022). It is not confirmed for the P100 Pro, which differs in electronics and mounting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill it keep my P100 flying if the battery fails in the air?\u003c\/strong\u003e No. The hold-up energy is for the electronics on the ground during a swap, not for the motors. It is not a flight backup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy P100 reboots every time I change batteries. Is it the UPS module?\u003c\/strong\u003e That is the classic UPS symptom, especially if it happens with every battery and the aircraft behaves normally once a battery is seated. Rule out the battery and socket first by swapping with several batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does it look like a battery problem?\u003c\/strong\u003e Because it only appears at the battery swap. Operators see the restart when a battery comes out and assume the battery or the socket is at fault. If every battery does the same thing, the batteries are not the cause.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe aircraft will not turn on at all. Will a new UPS module fix it?\u003c\/strong\u003e Rarely. An aircraft that will not power on with a known-good battery has a problem upstream of the UPS module — the socket, busbar, cable hub or the battery itself.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan a UPS module be weak rather than dead?\u003c\/strong\u003e Yes. A weakening module may survive a fast swap and fail a slow one. Time your swaps; if speed decides whether the aircraft restarts, the module is losing its hold-up.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it dangerous to keep flying with a failed UPS module?\u003c\/strong\u003e A cold restart at each swap is slow rather than dangerous. Any loss of power in flight is a different fault and needs to be diagnosed before the aircraft flies again.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it come with screws or cables?\u003c\/strong\u003e No. It is the module only. Reuse your original fasteners and harness, or order damaged ones by their own part numbers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I fit it myself?\u003c\/strong\u003e If you are comfortable working inside the electronics bay and handling connectors carefully, yes. Remove the battery, let the aircraft discharge, photograph the original in place, and reconnect exactly as it was.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I know the new module is working?\u003c\/strong\u003e Power the aircraft, let it acquire positioning and link, then swap the battery. The electronics, link and positioning should stay up through the gap. Try a slower swap as well.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat usually kills a UPS module?\u003c\/strong\u003e Heat cycling, vibration, moisture and spray chemistry getting into the electronics bay, and the gradual ageing of the stored-energy element that does the holding.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it the same as the battery socket?\u003c\/strong\u003e No. The battery socket, XAG part number 14-005-00027, is where the flight battery connects. The UPS module is a separate electronic assembly further along the power path.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the part number?\u003c\/strong\u003e Look for XAG part number 05-002-01262 on the module you removed. If you cannot read it, photograph the module in place and send it to us, and we will confirm the match.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you sell P100 Pro electronics too?\u003c\/strong\u003e This module is identified for the original P100 only. P100 Pro electronics differ, so match the part number on your aircraft rather than assuming the two are interchangeable.\u003c\/p\u003e","brand":"XAG","offers":[{"title":"Default Title","offer_id":68139957649728,"sku":"05-002-01262","price":324.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0923\/0159\/0848\/files\/xag-p100-oem-ups-module-1.png?v=1794884561","url":"https:\/\/aresacres.com\/pt\/products\/xag-p100-oem-ups-module","provider":"Ares Acres","version":"1.0","type":"link"}