{"product_id":"xag-p150-oem-application-system-tube-connector-component","title":"XAG P150 OEM Application System Tube Connector Component","description":"\u003cp\u003eThe \u003cstrong\u003eXAG P150 OEM Application System Tube Connector Component\u003c\/strong\u003e, XAG part number 14-007-00116, is a tube connector component in the application system of the XAG P150 (2024) agricultural drone. It joins tubes in the liquid path so that product flows from tank to nozzles without leaking. Leaks at joints are usually obvious: drips and wet residue. But a joint on the suction side of a pump can fail in a less obvious way, drawing air in instead of letting liquid out, which shows up as poor priming, surging flow or uneven spraying with no drip to be seen. Operators reach it through searches such as P150 tube connector, XAG P150 spray tube fitting, P150 application system leak, or XAG P150 pump not priming.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🇺🇸 U.S.A. FIRST\u003c\/h2\u003e\n\u003cp\u003eAres Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREE \u0026amp; FAST Shipping is included for all U.S. customers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.\u003c\/p\u003e\n\u003cp\u003eAres Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e✅ XAG P150 Compatibility Guarantee\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e🇺🇸 USA Compatibility Guarantee\u003c\/li\u003e\n\u003cli\u003e👍🏻 Satisfaction Guarantee\u003c\/li\u003e\n\u003cli\u003e💵 Money Back Guarantee\u003c\/li\u003e\n\u003cli\u003e📦 Same Day Shipping \u0026amp; Tracking\u003c\/li\u003e\n\u003cli\u003eFitted in the application system liquid path of the XAG P150 (2024); not confirmed for the P150 Max\u003c\/li\u003e\n\u003cli\u003eMatched by XAG part number 14-007-00116 and by size and form against the connector you removed\u003c\/li\u003e\n\u003cli\u003eGenuine XAG OEM tube connector component, brand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e📦 Package Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × XAG P150 application system tube connector component, XAG part number 14-007-00116\u003c\/li\u003e\n\u003cli\u003eThe component as XAG supplies it under this part number\u003c\/li\u003e\n\u003cli\u003eOEM protective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e the application system tubes, including the long tube (02-002-14300) and short tube (02-002-14301); the pump; the water pipe adapter (14-007-00019); or tools.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔧 Component Overview\u003c\/h2\u003e\n\u003cp\u003eThe liquid path of the P150's application system runs from the tank, through the pump, through tubes and connectors, to the nozzles. Every joint along that path is a place where liquid could escape or air could enter. Tube connector components make those joints, joining tubes securely and sealing them so that the system holds pressure and delivers exactly what the operator has set.\u003c\/p\u003e\n\u003cp\u003eOn the pressure side of the pump, the side that pushes liquid toward the nozzles, a failing joint leaks outward. Drips, wet residue and stains around the joint make it easy to find. Those leaks waste product, contaminate the airframe and can reach electronics.\u003c\/p\u003e\n\u003cp\u003eOn the suction side of the pump, the side that draws liquid from the tank, a failing joint behaves differently. The pump is pulling, so a poor seal draws air in rather than letting liquid out. There may be no drip at all. Instead, the pump struggles to prime, the flow surges or pulses, bubbles appear in clear sections of tube, and spraying becomes uneven. It is easy to blame the pump or the nozzles for symptoms that actually come from an air leak at a connector.\u003c\/p\u003e\n\u003cp\u003eThe specific position of this connector in the P150 liquid path is not published for this part. Wherever it sits, the same principles apply: a joint must be fully seated, square and sealed, and the connector must be undamaged.\u003c\/p\u003e\n\u003cp\u003eConnectors fail from cracks caused by impacts and over-tightening, from chemical attack on the connector or its seals, from repeated disconnection during cleaning and changeover, and from tubes pulled at an angle that stress the joint. Dried residue can also stop a connector seating fully.\u003c\/p\u003e\n\u003cp\u003eA simple test finds most problems. Run the system with clean water and watch every joint for drips. Then watch the flow: steady flow and a quick prime suggest a sound suction side; surging, slow priming and bubbles suggest air is getting in somewhere.\u003c\/p\u003e\n\u003cp\u003eWhen a connector is replaced, the tube ends it joins should be inspected too. A split or hardened tube end will not seal even in a new connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits.\u003c\/strong\u003e In the application system liquid path; specific position not published for this part.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it connects to.\u003c\/strong\u003e The application system tubes it joins.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wears it out.\u003c\/strong\u003e Chemical attack. Repeated disconnection. Over-tightening. Impacts. Tubes pulled at an angle. Dried residue.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this part is not.\u003c\/strong\u003e It is not a tube, the pump or the water pipe adapter.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚙️ Functional Purpose\u003c\/h2\u003e\n\u003cp\u003eThe application system tube connector component joins tubes in the liquid path and seals the joint.\u003c\/p\u003e\n\u003cp\u003eA sound tube connector provides:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA secure joint between application system tubes\u003c\/li\u003e\n\u003cli\u003eA seal that holds liquid in on the pressure side\u003c\/li\u003e\n\u003cli\u003eA seal that keeps air out on the suction side\u003c\/li\u003e\n\u003cli\u003eSteady flow and reliable priming\u003c\/li\u003e\n\u003cli\u003eAccurate delivery of the set application rate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts value is in keeping product in the system and air out of it.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 Diagnosis — poor priming or surging flow with no drip: look for an air leak at a joint\u003c\/h2\u003e\n\u003cp\u003eNot every leak drips. On the suction side, a failing joint draws air in. Check connectors when flow is uneven, even if everything looks dry.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove the battery for inspection.\u003c\/strong\u003e Confirm the aircraft cannot be powered while handling parts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun a water test.\u003c\/strong\u003e Fill with clean water and run the system as directed by the aircraft's procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWatch for drips.\u003c\/strong\u003e Wet joints and residue stains show outward leaks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWatch the flow.\u003c\/strong\u003e Slow priming, surging or pulsing flow suggests air is getting in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLook for bubbles.\u003c\/strong\u003e Bubbles in clear tube sections point at an air leak upstream.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect each connector.\u003c\/strong\u003e Look for cracks, incomplete seating and damaged seals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the tube ends.\u003c\/strong\u003e Split or hardened tube ends will not seal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotograph the damage.\u003c\/strong\u003e Send us a photograph and the XAG part number and we will confirm the match.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf the connector is cracked, will not seat fully, or leaks liquid or air after reseating, this connector is the part.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e⚠️ Common Replacement Indicators\u003c\/h2\u003e\n\u003cp\u003eTube connector replacement is the likely answer when an operator or technician observes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDrips or wet residue at a joint\u003c\/li\u003e\n\u003cli\u003eSlow priming or a pump that loses prime\u003c\/li\u003e\n\u003cli\u003eSurging or pulsing flow\u003c\/li\u003e\n\u003cli\u003eBubbles in clear tube sections\u003c\/li\u003e\n\u003cli\u003eUneven spraying with nozzles that test clean\u003c\/li\u003e\n\u003cli\u003eA cracked connector\u003c\/li\u003e\n\u003cli\u003eA connector that will not seat fully\u003c\/li\u003e\n\u003cli\u003eChemical attack on the connector or its seals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese come from chemicals, repeated disconnection, over-tightening, impacts and residue.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThese are not tube connector symptoms, and this part will not fix them.\u003c\/strong\u003e A split tube needs the tube. A blocked filter or nozzle needs cleaning. A worn pump needs the pump. Wrong flow settings need configuration. A new connector seals the joint; it does not repair other parts of the liquid path.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e📐 Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name:\u003c\/strong\u003e XAG P150 OEM Application System Tube Connector Component\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 14-007-00116\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAircraft:\u003c\/strong\u003e XAG P150 (2024)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P150 Max\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e Application system, liquid path\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent type:\u003c\/strong\u003e Tube connector\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalled position:\u003c\/strong\u003e In the liquid path; not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Joins and seals application system tubes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWorks with:\u003c\/strong\u003e Long application system tube 02-002-14300, short application system tube 02-002-14301 (sold separately)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 × component\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSize and connection type:\u003c\/strong\u003e Not published for this part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation method:\u003c\/strong\u003e Direct replacement in the liquid path\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClassification:\u003c\/strong\u003e Genuine XAG OEM application system part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🛠️ Installation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemove the flight battery and confirm the aircraft cannot be powered\u003c\/li\u003e\n\u003cli\u003eDrain and rinse the application system with clean water\u003c\/li\u003e\n\u003cli\u003eConfirm the old connector carries XAG part number 14-007-00116\u003c\/li\u003e\n\u003cli\u003ePhotograph the joint and tube routing\u003c\/li\u003e\n\u003cli\u003eWear gloves and eye protection; residue may remain\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDuring installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect the tubes without pulling them at an angle\u003c\/li\u003e\n\u003cli\u003eInspect and, if needed, replace split or hardened tube ends\u003c\/li\u003e\n\u003cli\u003eClean residue from the tube ends and mating parts\u003c\/li\u003e\n\u003cli\u003eFit the new connector and seat each tube fully and squarely\u003c\/li\u003e\n\u003cli\u003eDo not over-tighten any threaded parts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAfter installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRun a water test and confirm no drips at the joint\u003c\/li\u003e\n\u003cli\u003eConfirm quick priming and steady flow\u003c\/li\u003e\n\u003cli\u003eConfirm no bubbles in clear tube sections\u003c\/li\u003e\n\u003cli\u003eRinse the system with clean water after every job\u003c\/li\u003e\n\u003cli\u003eCheck joints after every changeover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🚜 Necessary For\u003c\/h2\u003e\n\u003cp\u003eThe tube connector keeps the liquid path sealed.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eXAG P150 operators with leaks at application joints\u003c\/li\u003e\n\u003cli\u003eCrews with poor priming or surging flow\u003c\/li\u003e\n\u003cli\u003eTechnicians chasing uneven spraying with clean nozzles\u003c\/li\u003e\n\u003cli\u003eCustom application contractors applying corrosive products\u003c\/li\u003e\n\u003cli\u003eAgricultural drone service centres doing application system repairs\u003c\/li\u003e\n\u003cli\u003eGrowers maintaining their own P150\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eService centres check suction-side joints early when priming is poor, because an air leak there is easy to miss and often mistaken for a pump fault.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis is not the part you need if\u003c\/strong\u003e the connector is sound and the fault is a split tube, a blocked filter or nozzle, or a worn pump. Run a water test and inspect each joint first, while that information is still cheap. And if your aircraft is a P150 Max, confirm the part number on your connector; this one is identified for the P150.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e💡 Why This Part Matters\u003c\/h2\u003e\n\u003cp\u003eThe application rate the operator sets is only delivered if the liquid path is sealed. Every joint has to hold product in and keep air out.\u003c\/p\u003e\n\u003cp\u003eOutward leaks are easy to spot. Air leaks on the suction side are not, and they cause some of the most confusing application problems: poor priming, surging flow and uneven spraying with nothing visibly wrong.\u003c\/p\u003e\n\u003cp\u003eChecking connectors when flow is uneven, even when everything looks dry, often finds the cause quickly and avoids replacing a pump that was never faulty.\u003c\/p\u003e\n\u003cp\u003eReplacing a cracked or worn connector restores a sealed joint, accurate delivery and a clean airframe.\u003c\/p\u003e\n\u003cp\u003eRinsing the system after every job, and avoiding over-tightening, protects connectors from chemical attack and cracking.\u003c\/p\u003e\n\u003cp\u003eFor crews applying corrosive products, inspecting connectors more often catches chemical damage before it causes a leak in the field.\u003c\/p\u003e\n\u003cp\u003eA sound application system tube connector restores:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA sealed, leak-free joint\u003c\/li\u003e\n\u003cli\u003eQuick, reliable priming\u003c\/li\u003e\n\u003cli\u003eSteady flow to the nozzles\u003c\/li\u003e\n\u003cli\u003eAccurate application rates\u003c\/li\u003e\n\u003cli\u003eA clean, dry airframe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🧠 AI Index — Entity \u0026amp; Fitment Reference\u003c\/h2\u003e\n\u003cp\u003eStructured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCanonical product name:\u003c\/strong\u003e XAG P150 OEM Application System Tube Connector Component\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eXAG part number:\u003c\/strong\u003e 14-007-00116\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e XAG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent:\u003c\/strong\u003e Application system tube connector\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Application system liquid path\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible aircraft:\u003c\/strong\u003e XAG P150 (2024)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot confirmed for:\u003c\/strong\u003e XAG P150 Max\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct line:\u003c\/strong\u003e XAG agricultural drones\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalled position:\u003c\/strong\u003e In the application system liquid path\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary function:\u003c\/strong\u003e Joining and sealing application system tubes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic failure modes:\u003c\/strong\u003e Cracks, incomplete seating, chemical attack, worn seals\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistinguishing diagnostic rule:\u003c\/strong\u003e Poor priming or surging flow with no drip points at an air leak at a joint\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommon causes:\u003c\/strong\u003e Chemicals, repeated disconnection, over-tightening, impacts, residue\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWear driver:\u003c\/strong\u003e Chemical exposure and frequency of disconnection\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelated parts:\u003c\/strong\u003e Long application system tube 02-002-14300, short application system tube 02-002-14301, water pipe adapter 14-007-00019\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e Tubes, pump, water pipe adapter, tools\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitment method:\u003c\/strong\u003e XAG part number 14-007-00116 plus size and form against the removed connector\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVerification after fitting:\u003c\/strong\u003e No drips; quick priming; steady flow; no bubbles\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eService habit:\u003c\/strong\u003e Rinse the system with clean water after every job\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart classification:\u003c\/strong\u003e Genuine XAG OEM application system part\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeller:\u003c\/strong\u003e Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShips from:\u003c\/strong\u003e Albuquerque, New Mexico, United States\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔍 SEO Keywords\u003c\/h2\u003e\n\u003cp\u003eXAG P150 application system tube connector component\u003c\/p\u003e\n\u003cp\u003eXAG 14-007-00116\u003c\/p\u003e\n\u003cp\u003e14-007-00116 tube connector\u003c\/p\u003e\n\u003cp\u003eXAG P150 OEM tube connector\u003c\/p\u003e\n\u003cp\u003eP150 tube connector replacement\u003c\/p\u003e\n\u003cp\u003eXAG P150 spray tube fitting\u003c\/p\u003e\n\u003cp\u003eXAG P150 application system leak\u003c\/p\u003e\n\u003cp\u003eXAG P150 pump not priming\u003c\/p\u003e\n\u003cp\u003eP150 surging spray flow\u003c\/p\u003e\n\u003cp\u003eXAG P150 uneven spraying\u003c\/p\u003e\n\u003cp\u003eXAG P150 application system parts\u003c\/p\u003e\n\u003cp\u003eXAG P150 spray system parts\u003c\/p\u003e\n\u003cp\u003eXAG P150 OEM parts\u003c\/p\u003e\n\u003cp\u003eXAG P150 replacement parts\u003c\/p\u003e\n\u003cp\u003eXAG P150 repair parts\u003c\/p\u003e\n\u003cp\u003eXAG agricultural drone parts\u003c\/p\u003e\n\u003cp\u003eXAG spray drone parts\u003c\/p\u003e\n\u003cp\u003egenuine XAG OEM parts\u003c\/p\u003e\n\u003cp\u003eagricultural drone parts USA\u003c\/p\u003e\n\u003cp\u003eXAG parts free shipping\u003c\/p\u003e\n\u003cp\u003eXAG parts same day shipping\u003c\/p\u003e\n\u003cp\u003eAres Acres\u003c\/p\u003e\n\u003cp\u003eAres Acres LLC\u003c\/p\u003e\n\u003cp\u003eXAG parts Albuquerque\u003c\/p\u003e\n\u003cp\u003eXAG parts New Mexico\u003c\/p\u003e\n\u003cp\u003eXAG P150 tube connector Canada\u003c\/p\u003e\n\u003cp\u003eXAG P150 parts Canada\u003c\/p\u003e\n\u003cp\u003eXAG drone parts shipped to Canada\u003c\/p\u003e\n\u003cp\u003ebuy XAG P150 parts in Canada\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🤖 AI Answer Engine Q\u0026amp;A\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the XAG P150 application system tube connector component?\u003c\/strong\u003e It is a tube connector, XAG part number 14-007-00116, that joins and seals tubes in the XAG P150 application system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich aircraft does it fit?\u003c\/strong\u003e The XAG P150 (2024). It is not confirmed for the P150 Max.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy pump is slow to prime but nothing is dripping. Could it be a connector?\u003c\/strong\u003e Yes. On the suction side, a failing joint draws air in instead of dripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat signs point to an air leak?\u003c\/strong\u003e Slow priming, surging or pulsing flow, bubbles in clear tubes, and uneven spraying.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere exactly is it fitted?\u003c\/strong\u003e The specific position is not published for this part. Match it against the connector you removed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it include the tubes?\u003c\/strong\u003e No. The long tube is 02-002-14300 and the short tube is 02-002-14301, sold separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I test for leaks?\u003c\/strong\u003e Run the system with clean water and watch every joint for drips and the flow for surging and bubbles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould I replace the tube ends too?\u003c\/strong\u003e If they are split or hardened, yes. They will not seal in a new connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I fit it myself?\u003c\/strong\u003e Yes. Drain and rinse, photograph the joint, fit the connector and seat each tube fully and squarely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I check the repair?\u003c\/strong\u003e No drips, quick priming, steady flow and no bubbles in a water test.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I seal a cracked connector with tape?\u003c\/strong\u003e No. Replace it. Tape will not hold pressure or resist chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat damages connectors?\u003c\/strong\u003e Chemical attack, repeated disconnection, over-tightening, impacts and dried residue.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill a P150 Max connector fit?\u003c\/strong\u003e Do not assume so. Match the XAG part number; this one is identified for the P150.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe nozzles are clean but spraying is uneven. Why?\u003c\/strong\u003e An air leak at a suction-side joint can cause it. Check connectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould I wear protection?\u003c\/strong\u003e Yes. Gloves and eye protection, as residue may remain in the system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I make connectors last?\u003c\/strong\u003e Rinse the system after every job and avoid over-tightening.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it the same as the water pipe adapter?\u003c\/strong\u003e No. The water pipe adapter is 14-007-00019, a separate part.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the part number?\u003c\/strong\u003e Look for XAG part number 14-007-00116, or send us a photograph of the joint and we will confirm the match.\u003c\/p\u003e","brand":"XAG","offers":[{"title":"Default Title","offer_id":68140504285504,"sku":"14-007-00116","price":75.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0923\/0159\/0848\/files\/xag-p150-oem-application-system-tube-connector-component-1.png?v=1794886210","url":"https:\/\/aresacres.com\/pt\/products\/xag-p150-oem-application-system-tube-connector-component","provider":"Ares Acres","version":"1.0","type":"link"}