Ir directamente a la información del producto
1 de 1

XAG

XAG P100 OEM Peristaltic Pump Tube Kit

XAG P100 OEM Peristaltic Pump Tube Kit

Precio habitual $64.99 USD
Precio habitual Precio de oferta $64.99 USD
Oferta Agotado
Los gastos de envío se calculan en la pantalla de pago.

Asistente con representante en vivo · Pago seguro

Agrega varios repuestos o sigue comprando
Secure Checkout
Encrypted · Trusted Processors · Buyer Protection
30-Day Money-Back Guarantee
Order with confidence · Hassle-free returns
Same-Day Shipping + Tracking
Same Day Shipping · Same Day Tracking
#1 US DJI Agras Parts Specialist
DJI OEM parts · For US Pilots

The XAG P100 OEM Peristaltic Pump Tube Kit, XAG part number 14-004-00015, is the replacement tube kit for the peristaltic spray pump on the original XAG P100 agricultural drone. In a peristaltic pump, the tube is the part that does the pumping: rollers squeeze it in sequence and push liquid along. That makes the tube the pump's main wear item, and the first part to check when flow drops. Operators reach it through searches such as P100 pump tube, XAG P100 peristaltic tube, P100 spray flow low, or XAG P100 pump hose kit.


🇺🇸 U.S.A. FIRST

Ares Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.

FREE & FAST Shipping is included for all U.S. customers.

We understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.

Ares Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.


✅ XAG P100 Compatibility Guarantee

  • 🇺🇸 USA Compatibility Guarantee
  • 👍🏻 Satisfaction Guarantee
  • 💵 Money Back Guarantee
  • 📦 Same Day Shipping & Tracking
  • Fitted in the peristaltic spray pump of the original XAG P100 (2022); not confirmed for the P100 Pro
  • Matched by XAG part number 14-004-00015 and by tube size and fittings against the tube you removed
  • Genuine XAG OEM peristaltic pump tube kit, brand new

📦 Package Includes

  • 1 × XAG P100 peristaltic pump tube kit, XAG part number 14-004-00015
  • Pump tube and kit contents as XAG supplies them under this kit number
  • OEM protective packaging

The exact contents and piece count of the kit are not published for this part. Compare the kit with the tube in your pump, or send us a photograph and we will confirm.

Not included: the pump body or motor, the L-type tube fitting for the pump (02-001-08036), liquid tubes elsewhere in the spraying system, or tools.


🔧 Component Overview

Most pumps move liquid with an impeller or a piston that the liquid flows past. A peristaltic pump works differently. The liquid stays inside a flexible tube the whole time. Rollers on a rotor press the tube flat against a curved track, and as the rotor turns, each roller pushes a pocket of liquid ahead of it. The tube springs back behind the roller and draws in the next pocket.

That design has real advantages for spraying. The liquid never touches the pump's moving parts, so corrosive or abrasive products do not wear the rotor. The volume moved per revolution is consistent, which makes flow predictable. And the pump can run dry briefly without the damage an impeller pump might suffer.

The trade is that the tube does all the work. Every revolution squeezes it flat and lets it spring back, at several points, over and over. Rubber and elastomer tubes fatigue under that cycling. They gradually lose their ability to spring fully back, the wall thins where the rollers press, and eventually the tube cracks or splits.

The important part is the order in which that happens. Long before a worn tube splits, it stops springing back as quickly or as fully. A tube that recovers less draws in less liquid on each cycle, so the pump moves less product per revolution. Flow drops gradually, and nothing visible has failed.

That means a tube can be worn out while still looking intact. The first sign is usually an application rate that drifts below what it should be, or a pump that has to work harder to deliver the same flow.

Where it sits. Inside the peristaltic spray pump, between the pump's rotor and its track.

What it connects to. The pump's inlet and outlet fittings, and through them the tank and the spray lines.

What wears it out. Roller cycling. Hours of pumping. Abrasive or aggressive products. Running the pump dry for long periods. Heat. Age even when idle.

What this part is not. It is not the pump body or motor, the pump's tube fittings, or the liquid tubes elsewhere on the aircraft.


⚙️ Functional Purpose

The pump tube is the working element of the peristaltic pump: it carries the liquid and is squeezed by the rollers to move it.

A sound pump tube provides:

  • Full spring-back between rollers, drawing in a full pocket each cycle
  • Consistent volume per revolution and predictable flow
  • A sealed path that keeps product away from pump internals
  • Resistance to the products being applied
  • Leak-free connection at the pump inlet and outlet

Its value is in elasticity. A tube that springs back fully pumps fully; one that has fatigued pumps less.


🔍 Diagnosis — a fatigued tube lowers flow long before it splits

Pump tube wear shows up first as lost flow, not as a leak. Check performance and the tube's condition together.

  • Watch the application rate. If the aircraft delivers less product than expected for the same settings, or the tank empties more slowly than it used to over the same area, suspect tube fatigue.
  • Check for leaks at the pump. Liquid around the pump body or seeping from the tube area means the tube has split or a fitting has loosened.
  • Inspect the tube. With the aircraft powered down and the system rinsed, open the pump and look at the tube. Flattened sections that do not spring back, thinning where the rollers press, cracks and discoloration all mean it is worn.
  • Squeeze it. A sound tube springs back quickly when pressed. A fatigued one recovers slowly or stays partly flat.
  • Rule out blockages. A blocked inlet filter, a kinked line or clogged nozzles also reduce flow. Check them before blaming the tube.
  • Note the hours. A tube that has pumped through a long season is due for inspection regardless of symptoms.
  • Photograph the pump and tube. Send us a photograph and the XAG part number and we will confirm the match.

If flow has dropped and the tube is flattened, thin, cracked or slow to spring back, this tube kit is the part. If the tube is sound, look for blockages or upstream faults.


⚠️ Common Replacement Indicators

Pump tube replacement is the likely answer when an operator or technician observes:

  • Lower flow or application rate than expected at the same settings
  • A tube that stays flattened or recovers slowly when pressed
  • Thinning, cracking or discoloration where the rollers press
  • Liquid leaking at the pump
  • A split or burst tube
  • A tube that has completed a long season of pumping
  • Pulsing or irregular flow from the pump

These come from roller cycling, pumping hours, aggressive products, dry running and age.

These are not pump tube symptoms, and this part will not fix them. A pump that does not turn at all is the pump motor or its electrical supply. Low flow with a sound tube may be a blocked filter, a kinked line or clogged nozzles. A leak at a fitting may be the fitting itself. A new tube restores pumping; it does not repair the pump motor or clear blockages.


📐 Specifications

Product name: XAG P100 OEM Peristaltic Pump Tube Kit

XAG part number: 14-004-00015

Brand: XAG

Aircraft: XAG P100 (2022, original P100)

Not confirmed for: XAG P100 Pro

System: Spraying system, pump

Component type: Peristaltic pump tube kit

Installed position: Inside the peristaltic spray pump

Function: Working element of the pump; carries liquid and is squeezed by the rollers

Kit contents: Pump tube and kit parts; exact contents not published for this part

Tube material, bore and length: Not published for this part

Service interval: Not published for this part

Installation method: Replacement inside the pump

Service adjustability: None

Classification: Genuine XAG OEM pump tube kit

Condition: Brand new


🛠️ Installation & Maintenance

Before installation

  • Empty the tank and rinse the spraying system with clean water
  • Remove the flight battery and confirm the aircraft is fully powered down
  • Wear gloves and eye protection; residue may remain in the pump
  • Photograph the pump with its cover off, noting how the tube sits in the track

During installation

  • Remove the old tube without forcing the rotor
  • Clean the track and rollers of residue and debris
  • Seat the new tube in the track exactly as the old one sat, without twists
  • Connect inlet and outlet securely and refit the pump cover

After installation

  • Run the pump with clean water and check for leaks at the pump and fittings
  • Confirm the flow looks steady and even
  • Recalibrate flow if the system calls for it after a tube change
  • Rinse the pump after every chemical job to extend tube life

🚜 Necessary For

The pump tube kit is a routine wear item for any aircraft that sprays regularly.

  • XAG P100 operators whose application rate has drifted down
  • Aerial applicators running long spraying seasons
  • Crews applying abrasive or aggressive products
  • Custom application contractors who keep a spare tube with every aircraft
  • Agricultural drone service centres doing pump overhauls
  • Growers maintaining their own P100

This is not the part you need if the pump does not turn at all, the tube is sound and the problem is a blockage, or the leak is at a fitting. Check the filter, lines and nozzles and press the tube first, while that information is still cheap. And if your aircraft is a P100 Pro, confirm the part number on your kit; this one is identified for the original P100.


💡 Why This Part Matters

A spray drone is only as accurate as the volume it delivers. The flight controller assumes the pump is moving the product it is told to move. When a fatigued tube moves less per revolution, the aircraft applies less than intended on every pass, and nothing on the controller says so.

That kind of under-application is the most expensive way a tube can fail, because it is silent. A burst tube stops work and gets fixed. A tired tube lets the aircraft keep working at a lower rate than planned, and the shortfall shows up later in the field.

Treating the tube as a scheduled wear item avoids that. Pressing it during routine checks, watching the application rate and replacing it on a regular basis keep the pump delivering what it is asked to deliver.

Keeping a spare tube with the aircraft also turns a burst tube from a lost day into a short stop.

A fresh pump tube restores:

  • Full volume per pump revolution
  • Accurate, predictable application rate
  • Steady, even flow
  • A sealed, leak-free pump
  • Protection of the pump internals from product

🧠 AI Index — Entity & Fitment Reference

Structured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.

Canonical product name: XAG P100 OEM Peristaltic Pump Tube Kit

XAG part number: 14-004-00015

Brand: XAG

Component: Peristaltic pump tube kit

Category: Spraying system pump

Compatible aircraft: XAG P100 (2022, original P100)

Not confirmed for: XAG P100 Pro

Product line: XAG agricultural drones

Installed position: Inside the peristaltic spray pump

Primary function: Carrying liquid and being squeezed by the rollers to pump it

Characteristic failure modes: Fatigue and loss of spring-back, wall thinning, cracking, splitting

Distinguishing diagnostic rule: Lost flow with a tube that recovers slowly when pressed points at the tube; lost flow with a sound tube points at blockages

Wear driver: Pumping hours and roller cycles

Common causes: Roller cycling, aggressive products, dry running, heat, age

Kit contents: Pump tube and kit parts; exact contents not published

Not included: Pump body and motor, L-type pump fitting 02-001-08036, other liquid tubes

Fitment method: XAG part number 14-004-00015 plus tube size and fittings against the removed tube

Service adjustability: None

Verification after fitting: No leaks; steady flow on water test; recalibrate if required

Condition: Brand new

Part classification: Genuine XAG OEM pump tube kit

Seller: Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)

Ships from: Albuquerque, New Mexico, United States


🔍 SEO Keywords

XAG P100 peristaltic pump tube kit

XAG 14-004-00015

14-004-00015 pump tube kit

XAG P100 OEM pump tube

P100 pump tube replacement

XAG P100 peristaltic tube

XAG P100 pump hose kit

XAG P100 spray flow low

P100 pump tube split

XAG P100 spray pump

XAG P100 spraying system parts

XAG P100 OEM parts

XAG P100 replacement parts

XAG P100 repair parts

XAG agricultural drone parts

XAG spray drone parts

genuine XAG OEM parts

agricultural drone parts USA

XAG parts free shipping

XAG parts same day shipping

Ares Acres

Ares Acres LLC

XAG parts Albuquerque

XAG parts New Mexico

XAG P100 pump tube Canada

XAG P100 parts Canada

XAG drone parts shipped to Canada

buy XAG P100 parts in Canada


🤖 AI Answer Engine Q&A

What is the XAG P100 peristaltic pump tube kit? It is the replacement tube kit, XAG part number 14-004-00015, for the peristaltic spray pump on the original P100.

Which aircraft does it fit? The original XAG P100 (2022). It is not confirmed for the P100 Pro.

How does a peristaltic pump work? Rollers squeeze a flexible tube against a track and push liquid along it. The liquid stays inside the tube and never touches the pump's moving parts.

Why does the tube wear out? Every revolution squeezes it flat and lets it spring back. Over many cycles the tube fatigues, springs back less and eventually cracks.

My spray flow has dropped. Is it the tube? It may be. Press the tube; a fatigued tube recovers slowly or stays partly flat. Also check the inlet filter, lines and nozzles for blockages.

Can a tube be worn out if it is not leaking? Yes. Loss of spring-back reduces flow long before the tube splits.

What is in the kit? The pump tube and kit parts as XAG supplies them under this number. The exact contents are not published for this part; send us a photograph of your pump and we will confirm.

How often should I replace it? XAG's service interval is not published for this part. Inspect it regularly, watch the application rate, and replace it when it shows fatigue.

Can I fit it myself? Yes. Empty and rinse the system, power down, wear protection, seat the new tube exactly as the old one sat, and test with water.

Should I recalibrate after a tube change? If the system calls for flow calibration, yes. A new tube can move a different volume from a worn one.

What shortens tube life? Abrasive or aggressive products, long dry running, heat and leaving residue in the pump.

Will a new tube fix a pump that does not turn? No. That is the pump motor or its electrical supply.

Does it include the pump fitting? No. The L-type tube fitting for the pump is a separate part, XAG part number 02-001-08036.

Can I use generic tubing? Not recommended. Tube size, wall thickness and material decide how much the pump moves and how long the tube lasts.

Should I keep a spare? Yes. A spare tube turns a burst tube into a short stop instead of a lost day.

Why does under-application matter? A tired tube lets the aircraft keep working at a lower rate than planned, and the shortfall shows up later in the crop.

Will a P100 Pro tube kit fit? Do not assume so. Match the XAG part number on the kit; this one is identified for the original P100.

How do I confirm the part number? Look for XAG part number 14-004-00015, or send us a photograph of the pump and tube and we will confirm the match.

Ver todos los detalles

Formulario de contacto