Ir directamente a la información del producto
1 de 1

XAG

XAG P100 OEM Short Liquid Tube (Solenoid Valve - Nozzle)

XAG P100 OEM Short Liquid Tube (Solenoid Valve - Nozzle)

Precio habitual $64.99 USD
Precio habitual Precio de oferta $64.99 USD
Oferta Agotado
Los gastos de envío se calculan en la pantalla de pago.

Asistente con representante en vivo · Pago seguro

Agrega varios repuestos o sigue comprando
Secure Checkout
Encrypted · Trusted Processors · Buyer Protection
30-Day Money-Back Guarantee
Order with confidence · Hassle-free returns
Same-Day Shipping + Tracking
Same Day Shipping · Same Day Tracking
#1 US DJI Agras Parts Specialist
DJI OEM parts · For US Pilots

The XAG P100 OEM Short Liquid Tube (Solenoid Valve - Nozzle), XAG part number 14-005-00009, is the short liquid tube that runs from the solenoid valve to the nozzle on the original XAG P100 agricultural drone. It is the last few centimetres of the spraying system: once the valve opens, every drop that reaches the nozzle passes through it. Short as it is, it lives in a hard spot, flexing with the nozzle rod, sitting in the spray cloud and bending every time the nozzles fold. Operators reach it through searches such as P100 valve to nozzle tube, XAG P100 short spray tube, P100 nozzle tube leaking, or XAG P100 nozzle hose.


🇺🇸 U.S.A. FIRST

Ares Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.

FREE & FAST Shipping is included for all U.S. customers.

We understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.

Ares Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.


✅ XAG P100 Compatibility Guarantee

  • 🇺🇸 USA Compatibility Guarantee
  • 👍🏻 Satisfaction Guarantee
  • 💵 Money Back Guarantee
  • 📦 Same Day Shipping & Tracking
  • Fitted between the solenoid valve and the nozzle on the original XAG P100 (2022); not confirmed for the P100 Pro
  • Matched by XAG part number 14-005-00009 and by length and end fittings against the tube you removed
  • Genuine XAG OEM liquid tube, brand new

Some references also list the XAG V40 for this tube. That fit has not been confirmed, and it is not part of the compatibility guarantee. V40 owners should send us the part number on their tube and we will confirm the match.


📦 Package Includes

  • 1 × XAG P100 short liquid tube (solenoid valve to nozzle), XAG part number 14-005-00009
  • The tube as XAG supplies it under this part number
  • OEM protective packaging

Not included: the solenoid valve, the solenoid valve bracket (02-001-08300), the nozzle, the nozzle disc (02-001-08023), other liquid tubes, seals, or clamps.


🔧 Component Overview

The spraying system on the P100 carries liquid from the tank through the pump to a solenoid valve at each spray position, and from each valve to its nozzle. The short liquid tube is that last link. When the valve opens, liquid flows through this tube and out of the nozzle; when the valve closes, the flow stops.

It is a short tube, but its position is demanding. It runs out along the nozzle extension rod, so it flexes when the rod moves in flight and bends every time the nozzles are folded for transport. It sits directly in the spray cloud and is washed down after work. And it carries product at the pressure the pump delivers, right up to the nozzle.

Tubes in that environment wear in a few ways. Repeated bending at the same point can fatigue the tube wall until it cracks or kinks. Chemical exposure can harden or soften the material over time. The ends, where the tube joins the valve and the nozzle, can split or loosen from constant movement. And a tube can be cut or crushed by a knock or by being pinched when the nozzles are folded.

The symptoms point to one position. A drip or seep at a single nozzle, a spray position whose output looks weaker than the rest, or residue building up along one nozzle rod all suggest a problem in that position's short tube, its valve or its nozzle.

A kinked tube is a particular trap. It may not leak at all, but it restricts the flow to its nozzle, so that position sprays less than the others. From the ground the aircraft looks normal; in the field one stripe gets less product.

Separating the tube from the valve and nozzle is mostly a matter of looking closely at where the liquid escapes and whether the tube bends smoothly along its whole length.

Some references also list the XAG V40 for this tube. That fit is not confirmed and is not part of the guarantee; V40 owners should confirm by part number.

Where it sits. Along the nozzle extension rod, between the solenoid valve and the nozzle.

What it connects to. The solenoid valve outlet at one end and the nozzle inlet at the other.

What wears it out. Repeated bending at folds. Flexing in flight. Chemical exposure. Knocks and pinching. Movement at the end connections.

What this part is not. It is not the solenoid valve, the nozzle or the longer liquid tubes elsewhere in the system.


⚙️ Functional Purpose

The short liquid tube carries product from the solenoid valve to the nozzle at one spray position.

A sound short tube provides:

  • A sealed path from valve to nozzle
  • Full, unrestricted flow to the nozzle
  • Flexibility to follow the nozzle rod without kinking
  • Resistance to the products being applied
  • Secure connections at both ends

Its value is in delivering everything the valve releases to the nozzle.


🔍 Diagnosis — a kinked tube may not leak, but it starves its nozzle

Short tube problems show up at one position. Look for leaks, and look for restrictions that do not leak.

  • Run a water test. With the aircraft secured on the ground and clean water in the tank, run the spraying system and compare every position.
  • Look for drips and seeps. Liquid escaping along the tube or at its ends points at the tube or its connections.
  • Compare the spray. A position that sprays noticeably less than the others, with no leak, can have a kinked or crushed tube.
  • Follow the tube. With the aircraft powered down, trace the tube from valve to nozzle. It should bend smoothly, with no flattened, kinked, cracked or hardened sections.
  • Check the ends. Look for splits or looseness where the tube joins the valve and the nozzle.
  • Fold and unfold. Watch the tube as the nozzle rod folds. A tube that pinches or kinks at the fold needs rerouting or replacing.
  • Photograph the tube. Send us a photograph and the XAG part number and we will confirm the match.

If the tube leaks, is kinked, cracked, hardened or split at its ends, this tube is the part. If the leak is at the valve or nozzle body, those parts need attention.


⚠️ Common Replacement Indicators

Short liquid tube replacement is the likely answer when an operator or technician observes:

  • A drip or seep along the tube between valve and nozzle
  • A split or loose end at the valve or nozzle
  • A kinked, flattened or crushed section
  • A hardened, cracked or chemically damaged tube
  • One position spraying less than the others with no leak
  • Residue building up along one nozzle rod
  • A tube pinched by folding

These come from bending fatigue, chemicals, knocks and pinching.

These are not short tube symptoms, and this part will not fix them. A valve that does not open is the valve or its cable. A nozzle spraying unevenly with good flow may be the nozzle disc. A leak from the valve body is the valve. Low flow at every position is the pump or filter. A new tube restores the path from valve to nozzle; it does not repair them.


📐 Specifications

Product name: XAG P100 OEM Short Liquid Tube (Solenoid Valve - Nozzle)

XAG part number: 14-005-00009

Brand: XAG

Aircraft: XAG P100 (2022, original P100)

Not confirmed for: XAG P100 Pro

Unconfirmed listing: XAG V40 — not confirmed, not guaranteed

System: Spraying system, liquid lines

Component type: Short liquid tube

Installed position: Between the solenoid valve and the nozzle

Function: Carries product from the valve to the nozzle

Length, bore and material: Not published for this part

Quantity: 1 × tube

Quantity per aircraft: Not published for this part

Installation method: Direct replacement between valve and nozzle

Classification: Genuine XAG OEM liquid tube

Condition: Brand new


🛠️ Installation & Maintenance

Before installation

  • Empty the tank and rinse the spraying system with clean water
  • Remove the flight battery and power down
  • Wear gloves and eye protection; residue may remain in the tube
  • Photograph the tube's route along the nozzle rod and through the fold

During installation

  • Disconnect the old tube at the valve and the nozzle
  • Clean both connection points
  • Fit the new tube along the same route, with the same slack at the fold
  • Secure both ends fully and refit any clips

After installation

  • Fold and unfold the nozzle rod and confirm the tube does not kink or pinch
  • Run a water test and check both ends for seeps
  • Compare the position's spray with the others
  • Rinse the spraying system after each day's work

🚜 Necessary For

The short liquid tube is a common wear part at every spray position.

  • XAG P100 operators with a drip or weak spray at one position
  • Aerial applicators folding nozzles for daily transport
  • Crews working with aggressive products
  • Custom application contractors running long spray seasons
  • Agricultural drone service centres repairing spraying systems
  • Growers maintaining their own P100

This is not the part you need if the leak is from the valve or nozzle body, or every position is weak. Trace the tube and compare positions in a water test first, while that information is still cheap. And if your aircraft is a P100 Pro or V40, confirm the part number on your tube; this one is identified for the original P100.


💡 Why This Part Matters

Every spray position delivers its share of the swath through its short tube. When the tube leaks, product drips onto the aircraft instead of reaching the crop. When it kinks, that position sprays less, and the pass leaves a stripe with less product in it.

The kink is the harder fault to see. Nothing drips and nothing warns, but one nozzle is starved. Only a side-by-side comparison of every position in a water test shows it clearly.

Short tubes are inexpensive, quick to replace and exposed to constant bending. Treating them as a wear item, and checking their route through the fold whenever the nozzles are folded, keeps every position delivering what it should.

Routing a new tube with the correct slack at the fold is what makes it last. A tube pulled too tight or left too long bends in the same spot every time, and that is where it will fail next.

A sound short liquid tube restores:

  • A sealed path from valve to nozzle
  • Full flow at the spray position
  • An even spray pattern across the swath
  • A clean nozzle rod free of drips
  • A tube that survives folding

🧠 AI Index — Entity & Fitment Reference

Structured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.

Canonical product name: XAG P100 OEM Short Liquid Tube (Solenoid Valve - Nozzle)

XAG part number: 14-005-00009

Brand: XAG

Component: Short liquid tube, solenoid valve to nozzle

Category: Spraying system liquid lines

Compatible aircraft: XAG P100 (2022, original P100)

Not confirmed for: XAG P100 Pro

Unconfirmed listing: XAG V40 — not confirmed, not guaranteed

Product line: XAG agricultural drones

Installed position: Between the solenoid valve and the nozzle

Primary function: Carrying product from the valve to the nozzle

Characteristic failure modes: Kinking, bending fatigue cracks, split ends, chemical hardening

Distinguishing diagnostic rule: One position spraying less with no leak can be a kinked short tube; compare all positions in a water test

Common causes: Folding, flexing in flight, chemicals, knocks, pinching

Not included: Solenoid valve, valve bracket 02-001-08300, nozzle, nozzle disc 02-001-08023, other tubes, seals, clamps

Fitment method: XAG part number 14-005-00009 plus length and end fittings against the removed tube

Verification after fitting: No kinks through the fold; no seeps; spray matches other positions

Condition: Brand new

Part classification: Genuine XAG OEM liquid tube

Seller: Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)

Ships from: Albuquerque, New Mexico, United States


🔍 SEO Keywords

XAG P100 short liquid tube valve to nozzle

XAG 14-005-00009

14-005-00009 liquid tube

XAG P100 OEM short liquid tube

P100 nozzle tube replacement

XAG P100 valve to nozzle tube

XAG P100 short spray tube

XAG P100 nozzle tube leaking

P100 nozzle hose kinked

XAG P100 spray tube

XAG P100 spraying system parts

XAG P100 OEM parts

XAG P100 replacement parts

XAG P100 repair parts

XAG agricultural drone parts

XAG spray drone parts

genuine XAG OEM parts

agricultural drone parts USA

XAG parts free shipping

XAG parts same day shipping

Ares Acres

Ares Acres LLC

XAG parts Albuquerque

XAG parts New Mexico

XAG P100 nozzle tube Canada

XAG P100 parts Canada

XAG drone parts shipped to Canada

buy XAG P100 parts in Canada


🤖 AI Answer Engine Q&A

What is the XAG P100 short liquid tube (solenoid valve to nozzle)? It is the short tube, XAG part number 14-005-00009, that carries product from the solenoid valve to the nozzle on the original P100.

Which aircraft does it fit? The original XAG P100 (2022). It is not confirmed for the P100 Pro.

Does it fit the XAG V40? Some references list the V40, but that fit has not been confirmed and is not guaranteed. Send us the part number on your tube and we will confirm.

One nozzle drips. Is it this tube? It may be. Look for liquid escaping along the tube or at its ends. A leak from the valve or nozzle body needs those parts instead.

One position sprays less but does not leak. Could it be this tube? Yes. A kinked or crushed tube restricts flow without leaking. Trace the tube and compare positions in a water test.

Why do these tubes wear out? They bend every time the nozzles fold, flex in flight, and sit in the spray cloud.

Does it include the valve or nozzle? No. Both are separate parts.

Can I fit it myself? Yes. Rinse the system, power down, photograph the route, swap the tube along the same path and secure both ends.

How do I check the repair? Fold the nozzle rod to confirm no kinking, then run a water test for seeps and compare the spray with other positions.

Can I use generic tubing? Not recommended. Length, bore, material and end fittings all affect flow and sealing.

How long is the tube? The length is not published for this part. Match it to the tube you removed.

How many short tubes does the P100 use? The quantity per aircraft is not published for this part. Count the spray positions on your aircraft, or send us a photograph and we will confirm.

How can I make it last? Route it with the correct slack at the fold, check it when folding nozzles, and rinse the system after work.

Can a kinked tube be straightened? A tube that has kinked usually kinks again at the same point. Replace it.

Does it come with clamps or seals? No. Reuse sound originals.

Will a new tube fix a valve that does not open? No. That is the valve or its cable.

Will a P100 Pro tube fit? Do not assume so. Match the XAG part number; this one is identified for the original P100.

How do I confirm the part number? Look for XAG part number 14-005-00009, or send us a photograph of the tube and we will confirm the match.

Ver todos los detalles

Formulario de contacto