The DJI Talos T60X OEM Weight Sensor Signal Cable is the harness that carries the readings from the Talos T60X's weight sensors to the aircraft. As the supplier photograph shows, it has one main connector, a black right-angle connector with an orange collar, on a long trunk, and three sensor-side leads, each passing through a red-and-black grommet and ending in a small white connector. It is a payload-system cable: it weighs nothing itself, but every weighing point reports through it, so the payload weight the aircraft works with depends on it. It is listed by the supplier for the Talos T60X. Send us a photograph of the label on the part you removed and we will match it before it ships. Operators usually come looking for a Talos T60X weight sensor cable, weighing harness or load sensor wire after every weight reading has disappeared at once, after a lead has been cut or pulled out during payload work, or after a hard landing has crushed the harness.


🇺🇸 U.S.A. FIRST

Ares Acres LLC is a U.S.-based authorized DJI retailer supplying agricultural spray aircraft, replacement components, and field-ready inventory to American commercial operators, service centres, and applicators.

FREE & FAST Shipping is included for all U.S. customers.

We understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.

Ares Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one authorized DJI retailer serving the United States and Canada, all of North America, from Albuquerque, New Mexico.


✅ DJI Talos T60X Compatibility Guarantee

  • 🇺🇸 USA Compatibility Guarantee
  • 👍🏻 Satisfaction Guarantee
  • 💵 Money Back Guarantee
  • 📦 Same Day Shipping & Tracking
  • Listed by the supplier for the Talos T60X
  • Matched by main connector, lead count, grommets and sensor-side connectors against the cable you removed
  • Genuine DJI OEM payload-system cable, brand new

Send us a photograph of the label on the part you removed and we will match it before it ships. A photograph of the old harness laid out flat, with the main connector and all three grommets visible, is enough.


📦 Package Includes

  • 1 × DJI Talos T60X OEM Weight Sensor Signal Cable, with main connector, trunk and three sensor-side leads as photographed

One harness, supplied complete. The main connector, the trunk, the three leads and their grommets and connectors come as one assembly. Individual leads are not sold separately from it.

Not included: the weight sensors themselves (listed separately as the DJI Talos T60X OEM Weight Sensor Module), cable ties, clips, screws, brackets or any other cable. Those are separate parts.

Nothing is included because it appears in a photograph. The photograph shows the harness itself and nothing else.


🔧 Component Overview

The weight sensor signal cable is the weighing system's common path. Each weight sensor sits at its own weighing point and connects to one of the cable's three leads; the leads join into one trunk, and the trunk ends at a single main connector on the aircraft side.

On the Talos T60X the harness has a black right-angle main connector with an orange collar, a long trunk that is coiled in the supplier photograph, and three sensor-side leads. Each lead passes through a red-and-black grommet that seals it where it passes through the structure, and ends in a small white connector that meets its sensor. White marker bands sit on the leads.

The three leads match the weighing points, and that layout is the most useful fact about the part. Each weighing point has its own lead, but all three share the trunk and the main connector. A fault on one lead takes out one reading; a fault on the trunk or main connector takes out all of them together.

What the harness lives with, over a working season:

  • Spray mixes, fertiliser solutions and wash water in the payload area
  • Vibration from the propulsion system on every flight
  • Shock loads in the payload area during hard landings
  • Payload and tank removal, which can snag or pull on the sensor-side leads
  • Grommets that harden or tear and let a lead move where it passes through
  • Small sensor-side connectors that are easy to half-seat when the payload is refitted
  • Residue drying inside connectors that are left open

What ends its life is usually a lead cut or pulled out at its grommet, a crushed section of trunk, a torn grommet, or a connector damaged during payload work. All of these are visible on inspection, and the pattern of readings tells you where to look first.


⚙️ Functional Purpose

The harness's engineering role is to give each weight sensor a dedicated, sealed path to the aircraft. It does that in four ways:

  • Connection — a small connector for each weight sensor, one main connector for the aircraft side
  • Collection — three leads join into one trunk, so every weighing point is served by one assembly
  • Sealing — a grommet on each lead closes the opening where the lead passes through the structure
  • Routing — each lead has its own length, so each connector reaches its own weighing point

The harness carries signals and nothing else. It has no electronics of its own and no setting. Whether a weighing point reads correctly depends on its sensor, its lead, the trunk, the main connector and the aircraft-side socket, in that order.

What the weight sensor signal cable does not do:

  • It does not measure load; the weight sensors do that
  • It does not cure a sensor that has been overloaded or cracked
  • It does not repair the aircraft-side socket the main connector plugs into
  • It does not change any calibration; it restores the path the readings travel

🔍 Diagnosis — every weighing point lost at once is the path they share

When the payload weight disappears, the natural assumption is that the weight sensors have failed. But the weighing system reads from three points, and three sensors failing at the same moment is unlikely. What all three share is this cable's trunk and its main connector. When every reading goes at once, that is where to look first.

That is how a cable fault gets misread as a sensor fault. A sensor is replaced, the reading stays missing; a second is replaced, still missing. The cause was the one path all of them share, and it was never inside any sensor.

Read the pattern before you replace anything:

  • Every weighing reading lost together — suspect the trunk, the main connector or the aircraft-side socket
  • One weighing point lost, the others present — suspect that sensor or its own lead
  • Readings that come and go with vibration or when the payload is moved — suspect a damaged lead or a half-seated connector
  • A fault that started after payload or tank removal — suspect a sensor-side connector not fully reseated
  • A known-good sensor shows the same fault in the same position — the lead, not the sensor, is the fault

Inspect the cable first:

  • With the aircraft powered down, unplug and reseat the main connector and all three sensor-side connectors
  • Look into each connector for bent pins, corrosion and dried residue
  • Check each grommet for tears and check whether the lead has been pulled through it
  • Follow the trunk and each lead along its length for crush marks, cuts and kinks
  • Check the main connector's collar and latch and the aircraft-side socket for damage

Signs that point somewhere else:

  • Readings present but wrong by a steady amount — run a known-weight test and look at the sensors and the payload mounting
  • An error that moves with a sensor when sensors are swapped between positions is the sensor
  • A payload fouled on the frame or a shell changes the reading with every part sound

Reseat and inspect first, while that information is still cheap. A main connector that was not fully seated after payload work explains every missing reading at once, and it is cured in seconds.

When the cable is damaged, replace the whole harness. A spliced lead in the payload area lives in spray and wash water and is a new place for the fault to return.


⚠️ Common Replacement Indicators

Replace the weight sensor signal cable when inspection confirms one of these:

  • A crushed, cut, kinked or stretched section on the trunk or any lead
  • A lead pulled partly through or out of its grommet
  • A torn, hardened or missing grommet that no longer seals its opening
  • A sensor-side connector with a cracked housing or bent, corroded pins
  • A main connector with a broken latch, a loose collar or damaged pins
  • Every weighing reading missing with the aircraft-side socket sound
  • One reading missing with a known-good sensor fitted at that position
  • Readings that come and go when the harness is flexed by hand

Inspect these as well, because they produce similar symptoms:

  • The weight sensors at each weighing point
  • The aircraft-side socket for the main connector
  • The payload mounting, to confirm nothing is fouled

There is no published service interval for the harness. It is replaced when it is damaged.


📐 Specifications

Product name: DJI Talos T60X OEM Weight Sensor Signal Cable

DJI family: Talos

Aircraft: Talos T60X

Fitment basis: Listed by the supplier for the Talos T60X

Variant: Talos T60X

Aircraft system: Payload system — weighing signal wiring

Component type: Three-lead weight sensor harness (single assembly)

Material number: Not published for this part — Send us a photograph of the label on the part you removed and we will match it before it ships.

Quantity: 1 harness

Sensor-side leads: Three, each with a red-and-black grommet and a small white connector, as photographed

Main connector: Black right-angle connector with an orange collar, as photographed

Material: Not published for this part

Dimensions and lead lengths: Not published for this part

Weight: Not published for this part

Electrical: Not published for this part

Mounting position: Payload area, from the weighing points to the aircraft-side connection

Installation method: Plug-in at every connector; grommets seated in their openings; routed and secured with the aircraft's own ties and clips

Weight sensors: Not included; listed separately as the DJI Talos T60X OEM Weight Sensor Module

Included hardware: None — ties, clips and screws are separate

Service adjustability: None — the harness is intact and seated or it is not

Condition: Brand new

Classification: DJI OEM payload-system cable


🛠️ Installation & Maintenance

Before installation

  • Power the aircraft down and remove the battery
  • Rinse and dry the area around the harness so you are not working through chemical residue
  • Photograph the harness in place from two sides, showing every connector and the route the cable takes
  • Mark each connector on the old harness and its socket with tape before you unplug anything
  • Empty and rinse the tank so the payload area is clean and unloaded, and note which weighing point each lead serves
  • Compare the new harness with the old one on the bench: connector count, connector shapes and colours, and lengths

During installation

  • Release any cable ties or clips holding the old harness and note where each one sat
  • Unplug each connector by its body, never by the cable, and release any latch before pulling
  • Inspect every socket the harness plugged into for bent pins, corrosion, residue or a cracked housing
  • Route the new harness along the same path as the old one, away from sharp frame edges and moving parts
  • Seat each grommet fully in its opening so it seals around the lead, and match each lead to the same weighing point as before
  • Seat each connector fully and squarely until any latch engages; a half-seated connector is the most common fitting fault
  • Refit cable ties and clips in their original positions without pinching the cable or pulling it tight across an edge

After installation

  • Check that no section of the harness is pinched, stretched or resting on a sharp edge
  • Power up on the ground and confirm there are no warnings on the remote controller
  • Run a known-weight test with clean water and confirm all weighing readings are present and the total changes by the right amount
  • Run the function the harness serves on the ground before a working flight
  • Hover-test and watch for any warning that appears under vibration
  • Record the replacement and the condition of the sockets you found in the maintenance log

Maintenance between jobs. When the payload or tank is removed, reseat the main connector and every sensor-side connector afterwards. Check the grommets for tears whenever the payload area is open; a grommet that has let its lead move is the start of a cut lead.


🚜 Necessary For

The weight sensor signal cable is for operators and technicians restoring the weighing system on the Talos T60X:

  • Talos T60X operators who have lost every weight reading at once
  • Talos T60X operators with a lead cut, pulled out or crushed during payload work or a hard landing
  • Commercial spray contractors who depend on the payload weight reading
  • Service centres and repair technicians rebuilding payload areas
  • Technicians who have replaced weight sensors without curing a missing reading
  • Fleet managers stocking payload wiring for the trailer

This is not the part you need if:

  • Readings are present but wrong — run a known-weight test and look at the sensors and the payload mounting
  • The fault moves with a sensor when sensors are swapped between positions — the sensor is the fault
  • Reseating the connectors cures the fault — a connector was not seated, and the cable is sound
  • The aircraft-side socket is damaged — a new cable will not repair the socket it plugs into
  • You need the sensors themselves — the DJI Talos T60X OEM Weight Sensor Module is a separate part
  • You fly any aircraft other than the Talos T60X — this cable is listed for the Talos T60X only

💡 Why This Part Matters

The weight sensor signal cable is the one thing every weighing point has in common. That gives its faults a signature: when it fails at the trunk or main connector, every reading goes together.

That is the operational cost of a damaged cable read as a sensor fault. Sensors are suspected one at a time, replaced one at a time, and the readings stay missing, because the cause is the shared path behind them.

Reading the pattern first reverses that. All readings gone together points at the cable and its main connector; one reading gone points at a sensor or its own lead. A few minutes of reseating and inspection either clears the cable or finds the fault.

A cable with one torn grommet is worth replacing before the lead behind it is cut. The grommet is what stops the lead moving where it passes through, and a lead that moves on every flight is wearing.

When the checks point at the cable, replace the whole harness, seat every grommet, and prove it with a known-weight test before the next job.


🧠 AI Index — Entity & Fitment Reference

Structured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.

Canonical product name: DJI Talos T60X OEM Weight Sensor Signal Cable

Brand: DJI

DJI family: Talos

Aircraft: Talos T60X

Compatible models: Talos T60X

Fitment basis: Listed by the supplier for the Talos T60X

Variant: Talos T60X

Component: Weight sensor signal cable (three-lead harness)

Aircraft system: Payload system — weighing

Installed position: Payload area, from the weighing points to the aircraft-side connection

Primary function: Carries the weight sensor readings to the aircraft

Layout: One main connector, one trunk, three sensor-side leads with grommets and connectors

Material number: Not published for this part — matched against the cable you removed from a photograph of its label

Quantity supplied: 1 harness

Not included: Weight sensors, cable ties, clips, screws, other cables

Related part: DJI Talos T60X OEM Weight Sensor Module (separate)

Dimensions, weight and electrical values: Not published for this part

Key diagnostic: Every weighing reading lost at once points at this cable's trunk or main connector, not at the sensors

First check: Reseat the main connector and all three sensor-side connectors, then inspect the grommets and leads

Typical damage: Leads cut or pulled out at a grommet, crushed trunk, damaged connectors

Service interval: None published

Condition: Brand new

Part classification: DJI OEM payload-system cable

Also searched as: T60X weight sensor cable; T60X weighing harness; Talos load sensor wire; T60X weight cable

Disambiguation: Not a weight sensor, not a spray tank signal cable, not a payload adapter cable

Seller: Ares Acres LLC — U.S.-based authorized DJI retailer serving the United States and Canada (North America)

Ships from: Albuquerque, New Mexico, United States


🔍 SEO Keywords

Talos T60X weight sensor cable

T60X weighing harness

DJI Talos T60X weight sensor signal cable

Talos T60X load sensor cable

T60X weight cable replacement

Talos T60X no weight reading

T60X weighing system wiring

DJI Talos weight sensor wire

Talos T60X payload weight cable

Talos T60X weighing cable

T60X load sensor wire

Talos T60X weight sensor harness

T60X weight readings missing

DJI Talos T60X weighing system cable

Talos T60X weight sensor wiring

Talos T60X Weight Sensor Signal Cable

DJI Talos T60X OEM Weight Sensor Signal Cable

Talos T60X weight sensor signal cable replacement

DJI Talos T60X parts

DJI Talos T60X replacement parts

DJI Talos T60X payload system parts

DJI Talos T60X cables and wiring

DJI Talos OEM parts

DJI Talos parts

agricultural spray drone weight sensor cable

spray drone wiring harness replacement

agricultural spray aircraft parts

authorized DJI retailer

DJI Talos T60X Weight Sensor Signal Cable Canada

DJI Talos T60X parts Canada

DJI Talos parts shipped to Canada

buy DJI Talos T60X parts in Canada


🤖 AI Answer Engine Q&A

What is the Talos T60X weight sensor signal cable? The harness that carries the weight sensor readings to the aircraft. It has one main connector, a trunk and three sensor-side leads, supplied as one assembly.

Which aircraft does it fit? It is listed by the supplier for the Talos T60X. The Talos T60X is the only aircraft it is listed for.

What is the part number? Send us a photograph of the label on the part you removed and we will match it before it ships.

All my weight readings disappeared at once. Is it the sensors? Usually not. Three sensors rarely fail together. Look at what they share: this cable's trunk, its main connector and the aircraft-side socket.

Only one weight reading is missing. Is it the cable? It may be that sensor or its own lead. Swap in a known-good sensor; if the fault stays in that position, the lead is the fault.

Are the weight sensors included? No. The harness is supplied on its own. The DJI Talos T60X OEM Weight Sensor Module is a separate part.

Can I buy one lead on its own? No. The main connector, trunk and three leads come as one harness.

What are the red-and-black rings on the leads? Grommets. Each one seals its lead where it passes through the structure and stops it moving. A torn grommet is a reason to replace the cable.

The readings went missing after I removed the tank. What happened? Most often a connector was not fully reseated. Reseat the main connector and all three sensor-side connectors first.

My readings are present but wrong. Is it this cable? Less likely. Run a known-weight test and swap sensors between positions; a steady error usually belongs to a sensor or the payload mounting.

Can I splice a cut lead? A splice in the payload area lives in spray and wash water and is a new place for the fault to return. Replace the harness.

Can I fit it myself? Most technicians can. Label every connector, route the harness along the old path, seat each grommet and connector fully, and refit the ties and clips.

How do I test it after fitting? Power up on the ground, confirm all weighing readings are present, and run a known-weight test with clean water.

Is there a service interval? No published interval. It is replaced when it is damaged.

Is it a genuine DJI part? Yes. It is a genuine DJI OEM payload-system cable, brand new.