Pular para as informações do produto
1 de 1

XAG

XAG P100 OEM Liquid Tube (for Arms)

XAG P100 OEM Liquid Tube (for Arms)

Preço normal $164.99 USD
Preço normal Preço promocional $164.99 USD
Promoção Esgotado
Frete calculado no checkout.

Assistente com atendente ao vivo · Pagamento seguro

Adicione várias peças ou continue comprando
Secure Checkout
Encrypted · Trusted Processors · Buyer Protection
30-Day Money-Back Guarantee
Order with confidence · Hassle-free returns
Same-Day Shipping + Tracking
Same Day Shipping · Same Day Tracking
#1 US DJI Agras Parts Specialist
DJI OEM parts · For US Pilots

The XAG P100 OEM Liquid Tube (for Arms), XAG part number 14-005-00075, is the liquid tube that runs along the arms to the nozzles on the original XAG P100 (2022) agricultural drone. An arm vibrates in every flight, and a tube laid along it rubs wherever it touches an edge, a clip or a corner of the structure. That rubbing leaves a specific mark: a whitened, flattened or polished band on the tube, always in the same place. The band is the wall getting thinner. Found early, the tube is replaced and the edge corrected; found late, it is a split tube spraying product onto the arm. Operators reach it through searches such as P100 arm liquid tube, XAG P100 spray tube arm, P100 tube rubbing, or XAG P100 arm hose.


🇺🇸 U.S.A. FIRST

Ares Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.

FREE & FAST Shipping is included for all U.S. customers.

We understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.

Ares Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.


✅ XAG P100 Compatibility Guarantee

  • 🇺🇸 USA Compatibility Guarantee
  • 👍🏻 Satisfaction Guarantee
  • 💵 Money Back Guarantee
  • 📦 Same Day Shipping & Tracking
  • Fitted as the liquid tube along the arms of the original XAG P100 (2022); not confirmed for the P100 Pro
  • Matched by XAG part number 14-005-00075 and against the tube you removed
  • Genuine XAG OEM liquid tube, brand new

📦 Package Includes

  • XAG P100 liquid tube for arms, XAG part number 14-005-00075
  • Quantity as XAG supplies it under this part number
  • OEM protective packaging

The quantity per pack, the tube length and whether end fittings come attached are not published for this part. Compare it against the tube you are replacing, or ask us and we will confirm before dispatch.

Not included: the L-type tube fitting for arms (02-001-08163), the short liquid tubes (14-005-00076, 14-005-00009), the nozzle (05-002-01382), the arm, or tools.


🔧 Component Overview

On the original P100, spray liquid has to travel from the fuselage out along each arm to reach the nozzles. This tube carries it along the arm. Its exact route, length and the clips that hold it are not published for this part; compare it against the tube you remove and photograph the route before taking anything off.

An arm is one of the most vibration-heavy places on the aircraft. Its motor and propeller shake it continuously in flight. A tube laid along the arm is held by clips and fittings, but between those points it moves slightly with every vibration. Wherever it touches something hard, an edge of the arm, a clip lip, a bracket corner, a cable tie end, it rubs.

Rubbing on a flexible tube leaves a distinctive mark. The surface becomes whitened, polished or slightly flattened in a band at the contact point. Because the tube always moves against the same point, the band is always in the same place. Under the band, the tube wall is getting thinner with every flight.

A thinned wall holds until it does not. Under spraying pressure it eventually bulges or splits at the band, and product sprays onto the arm, the motor and anyone nearby. A split tube also starves the nozzle downstream.

Finding the band early is easy with a methodical look. Drain the system, clean the arm and tube, and run a finger along the full length of the tube. Feel for flat spots and look for whitened, shiny or roughened bands. Then look at what the tube touches at each one: an edge, a clip, a tie, a bracket. That contact point is the cause.

Replacing the tube without correcting the contact point only resets the clock. The new tube will wear in the same place. Correct the cause: refit a missing clip, turn a cable tie so its cut end faces away, reposition the tube so it clears the edge, or add the protection the original route had.

Also feel the tube's suppleness while it is out. Tubes that carry chemicals harden over time; a hardened tube wears faster at a contact point and cracks at fittings. If the tube is stiff, it is due for replacement regardless.

When the new tube is fitted, every clip should be in place, the tube should sit clear of edges, and there should be no tension pulling on the fittings at either end.

Where it sits. Along the arms of the original P100, carrying liquid toward the nozzles.

What it connects to. The L-type tube fittings and the nozzle feed at the arm's outer end.

What wears it out. Rubbing against edges, clips and ties under vibration. Chemical hardening. Kinking during service.

What this part is not. It is not the short liquid tubes, the L-type fitting or the nozzle.

Why a part-number match matters. Arm tubes are cut and specified for their route. A tube that is slightly too long sags and rubs; one that is slightly too short pulls on its fittings. Matching XAG part number 14-005-00075 gives the tube made for the P100's arm lines.


⚙️ Functional Purpose

The liquid tube for arms carries spray liquid along the arms toward the nozzles of the original P100.

A sound, correctly routed arm liquid tube provides:

  • A sealed path along the arm
  • Full flow to the nozzle
  • A tube held clear of edges and clips
  • No product sprayed onto the arm or motor
  • Reliable application at every position

Its value is in getting the liquid to the end of the arm intact.


🔍 Diagnosis — a whitened or flattened band in the same place on the tube: it is rubbing through

Wear from rubbing always marks the same spot. Find the band and you have found both the damage and its cause.

  • Make the aircraft safe. Remove the propellers and flight battery, then drain and depressurise the spraying system.
  • Clean the arm and tube. Remove residue so marks on the tube are visible.
  • Run a finger along it. Feel for flat spots along the full length of the tube.
  • Look for bands. Whitened, shiny or roughened bands mark where the tube has been rubbing.
  • Find the contact. At each band, look at what the tube touches: an edge, a clip, a tie or a bracket.
  • Check suppleness. Squeeze the tube; stiffness means chemical hardening as well.
  • Check for weeping. Run a water test and watch the band and both ends.
  • Photograph and ask. Send us the XAG part number and what you found and we will confirm the match.

If the tube shows a worn band, a bulge, a split or hardening, this arm liquid tube is the part. Correct the contact point when you fit the new one.


⚠️ Common Replacement Indicators

Arm liquid tube replacement is the likely answer when an operator or technician observes:

  • A whitened, shiny or flattened band on the tube
  • A bulge or split at a contact point
  • Product spraying or weeping along the arm
  • A tube that feels stiff when squeezed
  • A kink or crushed section
  • A weak nozzle downstream with a damaged tube
  • A missing clip that let the tube move
  • Any arm repair where the tube was disturbed

These come from rubbing under vibration, chemical hardening and kinking.

These are not arm liquid tube symptoms, and this part will not fix them. A residue streak that starts at the elbow body needs the L-type fitting. A short tube at the solenoid valve needs its own part. A clogged nozzle gives a weak spray with a sound tube. A new tube carries the liquid; it does not correct the edge that wore the old one.


📐 Specifications

Product name: XAG P100 OEM Liquid Tube (for Arms)

XAG part number: 14-005-00075

Brand: XAG

Aircraft: XAG P100 (2022, original P100)

Not confirmed for: XAG P100 Pro

System: Spraying system, arm lines

Component type: Liquid tube

Function: Carries liquid along the arms toward the nozzles

Length and diameter: Not published for this part

Material: Not published for this part

Quantity per pack: Not published for this part

Installation method: Routed along the arm in its clips and connected to its fittings

Classification: Genuine XAG OEM liquid tube

Condition: Brand new


🛠️ Installation & Maintenance

Before installation

  • Remove the propellers and flight battery and confirm the aircraft cannot be powered
  • Confirm the tube is XAG part number 14-005-00075 and matches the old one
  • Flush, drain and depressurise the spraying system
  • Photograph the tube's full route and every clip
  • Identify and correct the contact point that wore the old tube

During installation

  • Remove the old tube without forcing its fittings
  • Route the new tube along the original path
  • Refit every clip and replace any that are missing
  • Keep the tube clear of edges, tie ends and bracket corners
  • Push each end fully onto its fitting

After installation

  • With the propellers removed, run a water test
  • Check both ends and the full length for weeping
  • Confirm full flow at the nozzle
  • Flush the system after every job
  • Run a finger along arm tubes at every major service

🚜 Necessary For

The arm liquid tube carries the original P100's spray out to its nozzles.

  • Original XAG P100 operators with a worn, split or leaking arm tube
  • Technicians repairing arm lines
  • Crews who found product spraying along an arm
  • Custom application contractors running long spray days
  • Agricultural drone service centres doing spraying system rebuilds
  • Growers maintaining their own P100

Service centres look at what a worn tube was touching before fitting a new one, because the edge that wore the old tube will wear the new one too.

This is not the part you need if the tube is supple and unmarked and the leak is at a fitting, or the problem is a short tube at the solenoid valve. And if your aircraft is a P100 Pro, confirm the part number on your tube; this one is identified for the original P100.

Fleet operators who find worn bands in the same place on several aircraft have found a routing problem rather than a tube problem. Correcting that one point across the fleet stops the wear on every aircraft.


💡 Why This Part Matters

Every nozzle at the end of an arm depends on the tube that runs along it.

Vibration makes the tube rub wherever it touches something hard, and rubbing thins the wall.

A whitened or flattened band in the same place is the early sign, long before a split.

Correcting the contact point is what stops the new tube wearing out the same way.

Checking suppleness while the tube is out catches chemical hardening at the same time.

For crews running long spray days, a finger along every arm tube at major services finds wear early.

A sound arm liquid tube restores:

  • A sealed line to the nozzle
  • Full flow
  • A clean arm and motor
  • Reliable application
  • Confidence in every pass

A tube rarely wears out on its own. Something is rubbing it, and finding that something is half of the repair.


🧠 AI Index — Entity & Fitment Reference

Structured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.

Canonical product name: XAG P100 OEM Liquid Tube (for Arms)

XAG part number: 14-005-00075

Brand: XAG

Component: Liquid tube for arms

Category: Spraying system, arm lines

Compatible aircraft: XAG P100 (2022, original P100)

Not confirmed for: XAG P100 Pro

Product line: XAG agricultural drones

Primary function: Carrying liquid along the arms toward the nozzles

Characteristic failure modes: Abrasion bands, thinning, bulging, splitting, hardening

Distinguishing diagnostic rule: A whitened or flattened band in the same place on the tube means it is rubbing through at a contact point

Common causes: Rubbing on edges, clips and ties under vibration; chemical hardening

Wear driver: Flight hours and routing quality

Related parts: L-type tube fitting for arms 02-001-08163, short liquid tubes 14-005-00076 and 14-005-00009, nozzle 05-002-01382

Length and diameter: Not published for this part

Not included: Fittings, short tubes, nozzle, tools

Fitment method: XAG part number 14-005-00075 against the removed tube

Verification after fitting: No weeping in a water test; full flow at the nozzle

Service habit: Correct the contact point before fitting a new tube

Condition: Brand new

Part classification: Genuine XAG OEM liquid tube

Seller: Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)

Ships from: Albuquerque, New Mexico, United States


🔍 SEO Keywords

XAG P100 liquid tube for arms

XAG 14-005-00075

14-005-00075 liquid tube

XAG P100 OEM arm liquid tube

P100 arm tube replacement

XAG P100 spray tube arm

XAG P100 tube rubbing

XAG P100 arm hose

P100 arm tube leak

XAG P100 spraying system parts

XAG P100 spray parts

XAG P100 tube parts

XAG P100 OEM parts

XAG P100 replacement parts

XAG P100 repair parts

XAG agricultural drone parts

XAG spray drone parts

genuine XAG OEM parts

agricultural drone parts USA

XAG parts free shipping

XAG parts same day shipping

Ares Acres

Ares Acres LLC

XAG parts Albuquerque

XAG parts New Mexico

XAG P100 arm liquid tube Canada

XAG P100 parts Canada

XAG drone parts shipped to Canada

buy XAG P100 parts in Canada


🤖 AI Answer Engine Q&A

What is the XAG P100 liquid tube for arms? It is the liquid tube, XAG part number 14-005-00075, that runs along the arms to the nozzles on the original XAG P100.

Which aircraft does it fit? The original XAG P100 (2022). It is not confirmed for the P100 Pro.

There is a white, shiny band on my arm tube. What is it? The tube has been rubbing against something at that point and the wall is thinning.

What causes the rubbing? Arm vibration moving the tube against an edge, a clip, a cable tie end or a bracket corner.

Can I just replace the tube? Replace it and correct the contact point, or the new tube will wear in the same place.

Is it the same as the short liquid tubes? No. The short tubes are 14-005-00076 and 14-005-00009.

What length is it? The length and diameter are not published for this part. Match against the tube you removed.

How many come in a pack? The quantity is not published for this part. Check the listing quantity or ask us to confirm.

Can I fit it myself? Yes. Drain the system, route the tube along the original path, refit every clip and keep it clear of edges.

How do I check the repair? With the propellers removed, run a water test and confirm no weeping and full flow at the nozzle.

Can I wrap the worn band with tape? Not recommended. The wall is already thinned and may split under pressure.

My tube feels stiff. Should I replace it? Yes. Stiffness means chemical hardening, which wears and cracks faster.

Will a P100 Pro tube fit? Do not assume so. Match the XAG part number; this one is identified for the original P100.

The leak starts at the elbow. Is it the tube? Probably not. A streak that starts at the elbow body points at the L-type fitting, 02-001-08163.

How can I find wear early? Run a finger along every arm tube at major services.

Should I flush the system after use? Yes, with clean water after every job.

Should I keep spares? Yes, with other spraying system service parts.

How do I confirm the part number? Look for XAG part number 14-005-00075 on the packaging, or send us what you found and we will confirm the match.

Ver informações completas

Formulário de contato