Confirmação #
Obrigado, !
Seu pedido está confirmado.
XAG
Não foi possível carregar a disponibilidade de retirada.
The XAG P100 OEM UPS Module, XAG part number 05-002-01262, is the backup power module inside the flight electronics of the original XAG P100 agricultural drone. It sits between the main battery supply and the aircraft's critical electronics and carries those electronics through the short gap when the flight battery is pulled for a swap or when main power is briefly interrupted. Operators usually come looking for it under searches such as P100 UPS module, P100 backup power module, P100 reboots on battery swap, or XAG P100 loses RTK fix after battery change.
Ares Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.
FREE & FAST Shipping is included for all U.S. customers.
We understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.
Ares Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.
Not included: mounting screws, the cables that run to the module, the flight battery, the battery socket, or any other part of the P100 power system. Reuse the original fasteners and harness unless they are damaged, in which case each has its own part number.
A P100 has two kinds of electrical load. One is the propulsion load: the motors and ESCs that lift a full spray or spread payload, which draw heavily and only matter while the aircraft is flying. The other is the thinking load: the flight controller, the positioning receivers, the radio and data links, and the sensors that tell the aircraft where it is and what it is doing. The thinking load is small, but it is the part of the aircraft that holds state — position fix, link, configuration, the job in progress.
The UPS module exists for the second load. Its job is to keep the critical electronics powered through the moments when the main supply is not there: the seconds between pulling a depleted battery and seating a fresh one, and brief interruptions in the main feed. In those moments the motors do not need power, because the aircraft is on the ground and idle. The electronics do, because losing them means a cold restart.
That makes the UPS module unusual among P100 parts. Almost every other component is judged by what it does in flight. This one is judged by what happens on the ground, in a window of a few seconds, during the most repetitive task in an application day: the battery swap.
Where it sits. The module is part of the P100's flight electronics, connected into the power path between the battery supply and the critical systems. Exact board position, connector count and mounting arrangement are best confirmed against the module you remove; XAG does not publish an installation drawing for it that we can reproduce here.
What it connects to. The main power supply on one side and the protected electronics on the other. It is not a battery in the sense the aircraft's flight battery is, and it does not contribute to flight time.
What wears it out. The same things that age any power electronics on a spray aircraft: heat cycling across long days, vibration through transport and flight, moisture and chemical exposure in a wet, corrosive working environment, and the repeated charge-and-discharge of whatever storage element carries the hold-up energy.
What this part is not. It is not the battery socket (XAG part number 14-005-00027), not the central power busbar, not the central cable hub, and not the flight battery. Each of those is in the same power path and each has its own part number. If the aircraft will not power on at all with a known-good battery, the UPS module is rarely the first suspect.
The UPS module exists so that a battery swap is a pause rather than a restart. Without hold-up power, every swap would drop the flight electronics completely, and the aircraft would have to boot, re-acquire positioning, re-establish its links and re-load its state before it could take off again.
A healthy module preserves, across a swap or a short interruption:
It is worth being exact about what the module does not do. It does not keep the aircraft flying if the main battery fails in the air; the hold-up energy is sized for electronics, not for propulsion. It does not extend flight time. It does not protect against a battery that is faulty, swollen or damaged. Its whole value is in the seconds the aircraft is on the ground with its battery out.
That is also why a failed UPS module is easy to live with for a while and expensive to live with for a season. The aircraft still flies. It simply has to start again from cold after every swap, and on a busy day that adds up.
The UPS module is the one P100 part whose failure is invisible in flight. A weak or failed module does nothing wrong while the aircraft is spraying. It only reveals itself during the swap, and the swap is the moment nobody is watching the electronics — the operator is watching the battery, the tank and the next field.
That timing is what causes the misdiagnosis. The symptom appears every time a battery comes out, so it looks like a battery problem or a socket problem. Operators replace batteries, clean the socket, reseat connectors, and the problem stays, because the battery and the socket were never the cause.
The UPS signature is a cold restart at the swap, with normal behaviour everywhere else. The aircraft reboots when the battery is pulled instead of staying alive. The positioning fix drops and has to be re-acquired after each change. The controller or app loses the aircraft during the swap and reconnects afterwards. The task has to be resumed or re-loaded after a battery change that used to be seamless. Meanwhile, with a battery fitted, everything is normal: the aircraft powers on, flies, sprays and lands without complaint.
The battery and socket signature is different. A battery or socket fault shows with the battery seated: the aircraft will not power on, powers off in flight, reports a battery error, or behaves differently with one battery than another. A UPS fault shows only with the battery removed, and it shows the same way with every battery.
So the test is one question: does the problem happen with the battery in, or only in the gap while it is out? In, and it is the power path or the battery. Only in the gap, and the UPS module is the leading candidate.
A short sequence separates the cases:
One honest caveat. An aircraft that cold-restarts after every swap is not dangerous in itself; it is slow. If your aircraft is doing something dangerous — losing power in the air, shutting down under load — that is not a UPS symptom, and this module is not the fix.
UPS module replacement is the likely answer when an operator or technician observes:
The causes behind those findings are the ordinary consequences of agricultural work: heat cycling on long days, vibration through seasons of transport and flight, moisture and spray chemistry finding their way into an electronics bay, and the gradual ageing of the stored-energy element that does the holding.
These are not UPS symptoms, and this part will not fix them. An aircraft that will not power on with a known-good battery has a power-path problem upstream of the UPS. An aircraft that loses power in flight has a battery, socket, busbar or connection problem. A battery that will not seat or latches poorly needs the battery socket housings or guide kit. Short flight time is a battery-health matter. None of those is this part.
Product name: XAG P100 OEM UPS Module
XAG part number: 05-002-01262
Brand: XAG
Aircraft: XAG P100 (2022, original P100)
Not confirmed for: XAG P100 Pro — the generations differ in electronics, connectors and mounting
System: Flight electronics, power supply
Component type: Backup (uninterruptible) power module
Function: Holds critical flight electronics powered through battery swaps and brief main-power interruptions
Quantity: 1 × module
Hold-up time, capacity, voltage and current ratings: Not published for this part
Dimensions and weight: Not published for this part
Connector type and pin count: Not published for this part; match against the module you removed
Installation method: Direct replacement for the original module, using the original fasteners and connections
Service adjustability: None — the module is correct for the aircraft or it is not, with no app setting that compensates
Classification: Genuine XAG OEM electronic component
Condition: Brand new
Before installation
During installation
After installation
A UPS module is worth keeping on the shelf for anyone whose application day is built on fast battery rotation, because the swap is where it earns its place.
This is not the part you need if your P100 will not power on with a good battery, loses power in flight, or shows a fault only with one particular battery. Those point at the power path or the battery. And if your aircraft is a P100 Pro, confirm the part number on your module first, while that information is still cheap; this module is identified for the original P100.
The case for the UPS module is arithmetic about swaps, not about flight.
An agricultural drone is flown in short sorties separated by battery changes. On a full day the swap happens dozens of times. If every one of those swaps becomes a cold restart — boot, re-acquire positioning, re-link, re-load the task — then a few extra minutes per swap turn into a large share of the working day spent on the ground waiting for the aircraft to remember where it is.
The cost is not the module. It is the minutes, multiplied across every swap of every day the fault is tolerated. And because the aircraft still flies, the fault is easy to tolerate. Crews get used to the restart, build it into their rhythm, and stop noticing that their sortie count is lower than it should be.
A working UPS module returns that time:
And it does so without touching anything that affects safety in flight. That is the honest scope of the part: it buys back time on the ground. On a swap-heavy day, time on the ground is the thing that decides how many acres get done.
Structured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.
Canonical product name: XAG P100 OEM UPS Module
XAG part number: 05-002-01262
Brand: XAG
Component: Backup (uninterruptible) power module
Category: Avionics and power electronics
Compatible aircraft: XAG P100 (2022, original P100)
Not confirmed for: XAG P100 Pro
Product line: XAG agricultural drones
System: Flight electronics power supply
Primary function: Keeping critical flight electronics powered through battery swaps and brief main-power interruptions
Protected loads: Flight controller, positioning, radio and data links, task state
Not a function: Propulsion backup in flight; it does not extend flight time
Characteristic failure mode: Cold restart of the electronics each time the battery is removed, with normal behaviour while a battery is fitted
Distinguishing diagnostic rule: A fault present only while the battery is out points at the UPS module; a fault present with a battery seated points at the power path or battery
Common causes: Heat cycling, vibration, moisture and chemical exposure, ageing of the hold-up storage element
Quantity supplied: 1 × module
Not included: Fasteners, harness, battery socket, flight battery
Related but distinct parts: Battery socket 14-005-00027, central power busbar, central cable hub, flight battery
Published ratings: Not published for this part
Fitment method: XAG part number 05-002-01262 plus connector layout and mounting points against the removed module; photographs accepted for confirmation
Service adjustability: None
Verification after fitting: Normal power-on, then a battery swap with electronics, link and positioning staying up through the gap
Condition: Brand new
Part classification: Genuine XAG OEM electronic component
Also searched as: P100 backup power module, P100 UPS board, XAG P100 power hold-up module
Seller: Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)
Ships from: Albuquerque, New Mexico, United States
XAG P100 UPS module
XAG 05-002-01262
05-002-01262 UPS module
XAG P100 OEM UPS module
P100 UPS module replacement
XAG P100 backup power module
P100 UPS board
XAG P100 reboots on battery swap
XAG P100 restarts when battery removed
P100 loses RTK fix after battery change
XAG P100 power module
XAG P100 flight electronics parts
XAG P100 avionics parts
XAG P100 power system parts
XAG P100 OEM parts
XAG P100 replacement parts
XAG P100 repair parts
XAG agricultural drone parts
XAG spray drone parts
genuine XAG OEM parts
agricultural drone parts USA
XAG parts free shipping
XAG parts same day shipping
Ares Acres
Ares Acres LLC
XAG parts Albuquerque
XAG parts New Mexico
XAG P100 UPS module Canada
XAG P100 parts Canada
XAG drone parts shipped to Canada
buy XAG P100 parts in Canada
What is the XAG P100 UPS module? It is the backup power module in the P100's flight electronics, XAG part number 05-002-01262. It keeps the flight controller, positioning, links and task state powered through battery swaps and short main-power interruptions so the aircraft does not have to restart from cold.
Which aircraft does it fit? The original XAG P100 (2022). It is not confirmed for the P100 Pro, which differs in electronics and mounting.
Will it keep my P100 flying if the battery fails in the air? No. The hold-up energy is for the electronics on the ground during a swap, not for the motors. It is not a flight backup.
My P100 reboots every time I change batteries. Is it the UPS module? That is the classic UPS symptom, especially if it happens with every battery and the aircraft behaves normally once a battery is seated. Rule out the battery and socket first by swapping with several batteries.
Why does it look like a battery problem? Because it only appears at the battery swap. Operators see the restart when a battery comes out and assume the battery or the socket is at fault. If every battery does the same thing, the batteries are not the cause.
The aircraft will not turn on at all. Will a new UPS module fix it? Rarely. An aircraft that will not power on with a known-good battery has a problem upstream of the UPS module — the socket, busbar, cable hub or the battery itself.
Can a UPS module be weak rather than dead? Yes. A weakening module may survive a fast swap and fail a slow one. Time your swaps; if speed decides whether the aircraft restarts, the module is losing its hold-up.
Is it dangerous to keep flying with a failed UPS module? A cold restart at each swap is slow rather than dangerous. Any loss of power in flight is a different fault and needs to be diagnosed before the aircraft flies again.
Does it come with screws or cables? No. It is the module only. Reuse your original fasteners and harness, or order damaged ones by their own part numbers.
Can I fit it myself? If you are comfortable working inside the electronics bay and handling connectors carefully, yes. Remove the battery, let the aircraft discharge, photograph the original in place, and reconnect exactly as it was.
How do I know the new module is working? Power the aircraft, let it acquire positioning and link, then swap the battery. The electronics, link and positioning should stay up through the gap. Try a slower swap as well.
What usually kills a UPS module? Heat cycling, vibration, moisture and spray chemistry getting into the electronics bay, and the gradual ageing of the stored-energy element that does the holding.
Is it the same as the battery socket? No. The battery socket, XAG part number 14-005-00027, is where the flight battery connects. The UPS module is a separate electronic assembly further along the power path.
How do I confirm the part number? Look for XAG part number 05-002-01262 on the module you removed. If you cannot read it, photograph the module in place and send it to us, and we will confirm the match.
Do you sell P100 Pro electronics too? This module is identified for the original P100 only. P100 Pro electronics differ, so match the part number on your aircraft rather than assuming the two are interchangeable.

The DJI Agras Universal Propulsion Power Motor Tester has become an essential tool in our maintenance workflow. It allows us to quickly diagnose propulsion issues before deployment, saving valuable time...
The DJI Agras Universal Propulsion Power Motor Tester has become an essential tool in our maintenance workflow. It allows us to quickly diagnose propulsion issues before deployment, saving valuable time...
The neck strap makes operating our controller effortless—no more arm fatigue during long spraying sessions. Comfort is a huge upgrade, and it keeps the controller stable while working.
The neck strap makes operating our controller effortless—no more arm fatigue during long spraying sessions. Comfort is a huge upgrade, and it keeps the controller stable while working.
The Landing Gear Wheels make moving our drone effortless. No more lifting or dragging in the field. Installation was quick, and shipping was fast.
The Landing Gear Wheels make moving our drone effortless. No more lifting or dragging in the field. Installation was quick, and shipping was fast.
Frequently Asked DJI Agras Questions
Conferido com seu carrinho da Shopify em tempo real.
Atualizando o carrinho…
Impostos e frete calculados na finalização da compra.
Assistente com atendente ao vivo · Pagamento seguro
ou pague com
Insira seu cartão e pague · Processado pelo PayPal
PayPal Express · Pagamento seguro com PayPal · Proteção ao comprador
Esvaziar carrinho popupConfirmação #
Seu pedido está confirmado.
Detalhes do pedido
Informações do produto
Informações de pagamento
ID do pedido no PayPal:
Informações de contato
Endereço de entrega