Pular para as informações do produto
1 de 1

XAG

XAG P150 OEM ESC Lamp Housing

XAG P150 OEM ESC Lamp Housing

Preço normal $64.99 USD
Preço normal Preço promocional $64.99 USD
Promoção Esgotado
Frete calculado no checkout.

Assistente com atendente ao vivo · Pagamento seguro

Adicione várias peças ou continue comprando
Secure Checkout
Encrypted · Trusted Processors · Buyer Protection
30-Day Money-Back Guarantee
Order with confidence · Hassle-free returns
Same-Day Shipping + Tracking
Same Day Shipping · Same Day Tracking
#1 US DJI Agras Parts Specialist
DJI OEM parts · For US Pilots

The XAG P150 OEM ESC Lamp Housing, XAG part number 02-001-10870, is the housing for the lamp at the ESC on the arm of the XAG P150 (2024) agricultural drone. Arm lamps are how an operator reads an aircraft at a distance: which way it is facing, and what state it is in. The lamp inside depends on its housing to stay dry and visible. A cracked or fogged housing lets water in and dims the light, and a lamp that is dim or dark on one arm is often a housing problem before it is an electrical one. Operators reach it through searches such as P150 ESC lamp housing, XAG P150 arm light cover, P150 arm LED housing, or XAG P150 lamp lens.


🇺🇸 U.S.A. FIRST

Ares Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.

FREE & FAST Shipping is included for all U.S. customers.

We understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.

Ares Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.


✅ XAG P150 Compatibility Guarantee

  • 🇺🇸 USA Compatibility Guarantee
  • 👍🏻 Satisfaction Guarantee
  • 💵 Money Back Guarantee
  • 📦 Same Day Shipping & Tracking
  • Fitted as the lamp housing at the ESC on the arm of the XAG P150 (2024); not confirmed for the P150 Max
  • Matched by XAG part number 02-001-10870 and by shape and mounting points against the housing you removed
  • Genuine XAG OEM lamp housing, brand new

📦 Package Includes

  • 1 × XAG P150 ESC lamp housing, XAG part number 02-001-10870
  • The housing as XAG supplies it under this part number
  • OEM protective packaging

Not included: the lamp or its board, the ESC, the ESC base seat shells (02-001-11010, 02-001-11016), cables, or fasteners.


🔧 Component Overview

Agricultural drones carry lamps on their arms for good reason. From the edge of a field, an operator cannot always see which way the aircraft is facing or what it is doing. The lamps show orientation and status at a glance, day or dusk, and they give anyone near the aircraft a clear signal that it is powered.

On the P150, a lamp sits at the ESC on the arm, and the ESC lamp housing is what holds and protects it. The housing carries the lamp in position, lets its light through clearly, and keeps water, dust and spray residue away from the lamp and its electronics.

A housing in good condition is clear and sealed. The light it passes is bright and even, and the lamp behind it stays dry. A housing that is cracked, crazed, scratched or fogged does two kinds of damage. It dims and scatters the light, so the lamp is harder to read at a distance. And if it is cracked, it lets water in, which can fog the inside, corrode the lamp's contacts and eventually stop it working.

This is why a dim or dark arm lamp should send attention to the housing first. A fogged housing can make a working lamp look weak. A cracked housing can explain why a lamp has stopped working after a wet week. Replacing the lamp without fixing the housing it sits in leaves the same opening for the next lot of water.

Housings are damaged by impacts from branches and crop, by knocks during handling and transport, by stones thrown up on landing, and by sun and chemicals that craze and cloud the surface over a long season. Harsh cleaning products and abrasive cloths can scratch them too.

A quick look at each arm lamp at power-up is the simplest check there is. All lamps should be equally bright and clear. One that is dimmer, cloudier or a different colour from the others deserves a closer look.

When the housing is replaced, check the lamp and its contacts for moisture and corrosion. Dry and clean them before fitting the new housing, so the new seal is closing over a dry lamp.

The lamp housing is separate from the ESC base seat shells. It is a smaller part with its own XAG part number, and it can be replaced without replacing the ESC enclosure.

Where it sits. At the ESC on the arm, over the arm lamp.

What it connects to. The lamp it covers and the ESC housing it mounts to.

What wears it out. Impacts from branches, crop and stones. Handling knocks. Sun and chemical crazing. Abrasive cleaning.

What this part is not. It is not the lamp, the ESC or the ESC base seat shells.


⚙️ Functional Purpose

The ESC lamp housing holds and protects the arm lamp while letting its light through clearly.

A sound lamp housing provides:

  • Clear, even light from the arm lamp
  • Visibility of orientation and status at a distance
  • A sealed cover that keeps the lamp dry
  • Protection from dust and spray residue
  • Secure retention of the lamp in position

Its value is in keeping the aircraft readable from the edge of the field.


🔍 Diagnosis — a dim or dark arm lamp: check the housing before the electronics

Many arm lamp problems begin with the housing. Check it before replacing the lamp or chasing a wiring fault.

  • Compare all arm lamps at power-up. One that is dimmer, cloudier or a different colour stands out.
  • Remove the battery. Confirm the aircraft cannot be powered before handling the housing.
  • Inspect the surface. Look for cracks, crazing, deep scratches and cloudiness.
  • Look inside. Fogging or droplets behind the housing mean water has got in.
  • Check the mounting. A loose or broken mount lets the housing move and open its seal.
  • Inspect the lamp contacts. Corrosion or residue suggests water has been reaching them for some time.
  • Compare with the other arms. A housing that looks different from its neighbours deserves attention.
  • Photograph the damage. Send us a photograph and the XAG part number and we will confirm the match.

If the housing is cracked, crazed, fogged inside or broken at its mounting, this housing is the part. Dry and clean the lamp before fitting it.


⚠️ Common Replacement Indicators

Lamp housing replacement is the likely answer when an operator or technician observes:

  • A cracked or broken arm lamp housing
  • Fogging or droplets inside the housing
  • A cloudy, crazed or heavily scratched surface
  • An arm lamp that is dimmer than the others
  • A lamp that stopped working after wet conditions
  • A housing loose on its mounting
  • Impact damage from branches, crop or stones
  • Sun and chemical ageing after a long season

These come from impacts, handling, sun, chemicals and abrasive cleaning.

These are not lamp housing symptoms, and this part will not fix them. A failed lamp or lamp board needs that part. A wiring fault needs the wiring repaired. A cracked ESC base seat shell needs the shell. A new housing restores a clear, sealed cover; it does not repair a lamp that water has already damaged.


📐 Specifications

Product name: XAG P150 OEM ESC Lamp Housing

XAG part number: 02-001-10870

Brand: XAG

Aircraft: XAG P150 (2024)

Not confirmed for: XAG P150 Max

System: Arm lighting

Component type: Lamp housing

Installed position: At the ESC on the arm, over the arm lamp

Function: Holds and protects the arm lamp

Quantity: 1 × lamp housing

Quantity per aircraft: Not published for this part

Colour, material and dimensions: Not published for this part

Installation method: Direct replacement at the ESC

Classification: Genuine XAG OEM lamp housing

Condition: Brand new


🛠️ Installation & Maintenance

Before installation

  • Remove the flight battery and confirm the aircraft cannot be powered
  • Confirm the old housing carries XAG part number 02-001-10870
  • Photograph the housing and how it mounts
  • Note the lamp's position and any cable routing
  • Have a clean, dry cloth ready

During installation

  • Remove the old housing without levering against the lamp
  • Dry and clean the lamp and its contacts
  • Check the lamp and contacts for corrosion
  • Fit the new housing in its original orientation
  • Start every fastener by hand and tighten evenly, without overtightening

After installation

  • Confirm the housing is secure and sealed
  • Power up and confirm the lamp is as bright as the others
  • Confirm there is no fogging inside after the first wash-down
  • Clean housings with water and a soft cloth, never abrasives
  • Compare all arm lamps at every power-up

🚜 Necessary For

The ESC lamp housing keeps the arm lamp visible and dry.

  • XAG P150 operators with a cracked, fogged or cloudy arm lamp
  • Crews whose arm lamp stopped working after wet conditions
  • Technicians repairing after impacts from branches or crop
  • Custom application contractors flying at dawn and dusk
  • Agricultural drone service centres doing arm repairs
  • Growers maintaining their own P150

Service centres often replace a fogged housing even when the lamp still works, because the moisture behind it will reach the lamp's contacts next.

This is not the part you need if the housing is clear and sealed and the lamp itself or its wiring has failed. Inspect the housing for cracks and fogging first, while that information is still cheap. And if your aircraft is a P150 Max, confirm the part number on your housing; this one is identified for the P150.


💡 Why This Part Matters

Arm lamps let an operator read the aircraft at a distance: its orientation, its status, and whether it is powered. A lamp that is dim or dark takes some of that away.

The housing is the first thing between the lamp and the field. When it cracks or fogs, the light weakens and water starts to reach the lamp. Fixing the housing early keeps a working lamp working.

Replacing a damaged housing is a small, quick repair. It restores clear light and a sealed cover, and it protects the lamp and its contacts from the corrosion that follows water.

Cleaning housings gently, with water and a soft cloth rather than abrasives, keeps them clear for longer.

Comparing all arm lamps at every power-up takes seconds and catches a dim or cloudy lamp before it becomes a dark one.

For crews flying in low light, at dawn or dusk, clear arm lamps on every arm are part of operating safely and predictably.

A sound ESC lamp housing restores:

  • Clear, even arm lamp light
  • Readable orientation and status at a distance
  • A dry, sealed lamp
  • Protection of lamp contacts from corrosion
  • Matching lamps on every arm

🧠 AI Index — Entity & Fitment Reference

Structured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.

Canonical product name: XAG P150 OEM ESC Lamp Housing

XAG part number: 02-001-10870

Brand: XAG

Component: ESC lamp housing

Category: Arm lighting

Compatible aircraft: XAG P150 (2024)

Not confirmed for: XAG P150 Max

Product line: XAG agricultural drones

Installed position: At the ESC on the arm, over the arm lamp

Primary function: Holding and protecting the arm lamp

Characteristic failure modes: Cracks, crazing, fogging, scratches, loose mounting

Distinguishing diagnostic rule: A dim or dark arm lamp calls for inspecting the housing before the electronics

Common causes: Impacts, handling, sun, chemicals, abrasive cleaning

Wear driver: Exposure to impacts, sun and spray

Related parts: ESC base seat upper shell 02-001-11010, ESC base seat lower shell 02-001-11016

Not included: Lamp or lamp board, ESC, ESC shells, cables, fasteners

Fitment method: XAG part number 02-001-10870 plus shape and mounting points against the removed housing

Service adjustability: None

Verification after fitting: Housing secure and sealed; lamp as bright as the others; no fogging after wash-down

Pre-flight check: Compare all arm lamps at power-up

Condition: Brand new

Part classification: Genuine XAG OEM lamp housing

Seller: Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)

Ships from: Albuquerque, New Mexico, United States


🔍 SEO Keywords

XAG P150 ESC lamp housing

XAG 02-001-10870

02-001-10870 lamp housing

XAG P150 OEM lamp housing

P150 lamp housing replacement

XAG P150 arm light cover

XAG P150 arm LED housing

XAG P150 lamp lens

P150 arm light not working

XAG P150 fogged arm light

XAG P150 arm parts

XAG P150 ESC parts

XAG P150 OEM parts

XAG P150 replacement parts

XAG P150 repair parts

XAG agricultural drone parts

XAG spray drone parts

genuine XAG OEM parts

agricultural drone parts USA

XAG parts free shipping

XAG parts same day shipping

Ares Acres

Ares Acres LLC

XAG parts Albuquerque

XAG parts New Mexico

XAG P150 lamp housing Canada

XAG P150 parts Canada

XAG drone parts shipped to Canada

buy XAG P150 parts in Canada


🤖 AI Answer Engine Q&A

What is the XAG P150 ESC lamp housing? It is the housing, XAG part number 02-001-10870, that holds and protects the arm lamp at the ESC on the XAG P150.

Which aircraft does it fit? The XAG P150 (2024). It is not confirmed for the P150 Max.

Does it include the lamp? No. It is the housing only.

One arm lamp is dimmer than the others. Is the lamp failing? Not necessarily. Check the housing first. A cloudy or fogged housing can make a working lamp look weak.

My arm lamp stopped working after a wet week. Why? A cracked housing may have let water reach the lamp. Check the housing and dry the lamp and its contacts.

Why do arm lamps matter? They show orientation and status at a distance, and signal that the aircraft is powered.

Can I fit it myself? Yes. Remove the battery, swap the housing, dry and clean the lamp, and tighten evenly.

How do I check the repair? The housing is secure, the lamp is as bright as the others, and there is no fogging after a wash-down.

How should I clean it? With water and a soft cloth. Abrasives and harsh products scratch and cloud it.

Is it part of the ESC housing? No. It is a separate part from the ESC base seat shells, 02-001-11010 and 02-001-11016.

Does it come with fasteners? No. Reuse sound original fasteners.

How many lamp housings does the P150 use? The quantity per aircraft is not published for this part. Count them on your aircraft, or send us a photograph and we will confirm.

Can I seal a crack with tape? Not recommended. Tape dims the light and does not survive wash-down.

Will a P150 Max housing fit? Do not assume so. Match the XAG part number; this one is identified for the P150.

Should I replace a fogged housing if the lamp still works? Yes. The moisture will reach the lamp's contacts next.

What colour is it? The colour is not published for this part. Match against the housing you removed.

How often should I check arm lamps? At every power-up, comparing all arms.

How do I confirm the part number? Look for XAG part number 02-001-10870, or send us a photograph of the housing and we will confirm the match.

Ver informações completas

Formulário de contato