Skip to product information
1 of 6

Ares Acres

DJI Agras T100 OEM Flow Meter Adapter (YC.JG.ZS006199)

DJI Agras T100 OEM Flow Meter Adapter (YC.JG.ZS006199)

Regular price $56.99 USD
Regular price Sale price $56.99 USD
Sale Sold out
Shipping calculated at checkout.
DJI Agras Model

Secure Stripe checkout · Free shipping · Cards, Apple Pay & Google Pay

Best for bundling multiple products
Secure Checkout
Encrypted · Trusted Processors · Buyer Protection
30-Day Money-Back Guarantee
Order with confidence · Hassle-free returns
Same-Day Shipping + Tracking
Same Day Shipping · Same Day Tracking
#1 US DJI Agras Parts Specialist
DJI OEM parts · For US Pilots

DJI Agras T100 Parts | DJI Agras T100 OEM | DJI Agras OEM Parts | Flow Meter Adapter | Spray System Flow Sensor Fitting | Liquid Delivery Interface Connector | DJI Material Number YC.JG.ZS006199

DJI Material Number YC.JG.ZS006199 — this is the official DJI part number for this exact component. Match it to your parts diagram or the label on the original part to confirm fitment; factory labels may carry a revision suffix, which is the same part.

🇺🇸 U.S.A. FIRST

Ares Acres LLC is a U.S.-based authorized DJI Agras reseller supporting American agricultural drone operators with genuine DJI Agras OEM replacement parts, accessories, and field-ready inventory.

FREE & FAST Shipping is included for all U.S. customers.

We understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.

We use specialized technicians to verify and dispatch the Flow Meter Adapter ordered.

Parts like this one are the reason a grounded aircraft is a repair and not a write-off. A single component held in U.S. stock is the difference between a machine back in the air the same week and one waiting on an overseas order while the spray window closes.

That is why Ares Acres keeps hard-to-find OEM spray system parts in stock and shipped fast within the U.S.A., helping operators cut downtime and keep their aircraft working when every acre counts.

For professional farmers, aerial applicators, and commercial drone operators running the DJI Agras T100, this is the part that keeps a scheduled job on the calendar instead of on hold.


✅ DJI Agras T70 / T70P / T100 Compatibility Guarantee

  • 🇺🇸 USA Compatibility Guarantee
  • 👍🏻 Satisfaction Guarantee
  • 💵 Money Back Guarantee
  • 📦 Same Day Shipping & Tracking
  • Genuine DJI Agras OEM liquid-delivery system component
  • Direct-fit replacement for the DJI Agras T70, T70P, and T100 flow meter assembly
  • Correct thread form and sealing geometry — no adapters, no thread tape improvisation, no non-OEM guesswork
  • Knowledgeable U.S.-based support before and after the sale

📦 Package Includes

  • 1 × DJI Agras T70 / T70P / T100 OEM Flow Meter Adapter
  • Integrated threaded connection assembly
  • OEM liquid-system interface fitting
  • OEM protective packaging

🔧 Component Overview

The DJI Agras T70 / T70P / T100 OEM Flow Meter Adapter is a precision liquid-system interface component engineered to provide a secure and leak-resistant connection between the aircraft's flow measurement system and critical spraying system plumbing. Designed specifically for DJI Agras T70, T70P, and T100 spraying platforms, this adapter serves as a critical connection point responsible for maintaining proper fluid transfer while supporting accurate flow meter operation during agricultural spraying missions.

Modern DJI Agras aircraft rely heavily on flow measurement systems to monitor liquid delivery rates, calculate application volumes, maintain spray consistency, and ensure accurate chemical deployment across agricultural fields. The flow meter adapter acts as a structural and hydraulic interface between fluid lines and flow sensing components, helping maintain reliable liquid movement throughout the spraying system.

Although compact in size, this component directly affects one of the most important operational variables in agricultural spraying: application accuracy. A damaged, cracked, leaking, worn, or improperly installed adapter can negatively impact fluid delivery, flow meter readings, pressure stability, chemical application rates, and overall spraying performance.

Constructed from DJI-spec chemical-resistant engineering materials, the assembly is engineered to withstand:

  • Continuous liquid spraying operations
  • Agricultural chemical exposure
  • Fertilizer applications
  • High-flow liquid movement
  • Pressure fluctuations
  • Vibration during flight
  • UV and environmental exposure
  • Transportation vibration
  • Daily commercial deployment
  • Long-term agricultural operation

The adapter serves as a critical support component within the liquid delivery system and helps maintain accurate communication between fluid movement and flow monitoring equipment. For commercial operators treating hundreds or thousands of acres annually, maintaining flow system integrity is essential for maximizing spraying precision, reducing waste, and protecting crop performance.

This is a spray-system-critical OEM component essential for maintaining reliable DJI Agras liquid application operations.

Find a weep with a paper towel, not a fingertip. Wipe the fitting and everything under it completely dry, fold a clean white towel around the joint, run the system on clean water, and then look at the towel. A seep too small to form a visible drop still marks paper immediately, and it will show you which side of the joint it is coming from. Check below the fitting as well, because liquid tracks along hose and structure and reappears somewhere that has nothing wrong with it.

Air drawn in and liquid pushed out look nothing alike, so establish which side of the pump this joint sits on from your parts diagram before you interpret anything. A joint ahead of the pump that is loose enough to pull air will never drip with the system off, but it sends bubbles through the meter and the reported rate goes unsteady. A joint after the pump loses liquid instead and stains. The symptom you have narrows down where to look.

Clear the cheap causes before you condemn a fitting. A packed tank strainer, one nozzle partly blocked or a check valve hung up, a hose section gone soft or pinched under a clip, and a tired pump all change what is delivered and can make the reading look like a plumbing fault. Pull and rinse the filter, run every nozzle on clean water and watch the patterns, and squeeze along the hose runs for a length that has lost its shape.

Ask what has been done to this joint, not only what it looks like now. A fitting that has been apart several times, that carries wrench marks or a polished flat on the hex, or that has a hose arriving at it on an angle instead of along its natural path, is a fitting living under constant side load. That is the one that seals when you retorque it and starts weeping again a week later, and no amount of tightening addresses the reason.

⚙️ Functional Purpose

The OEM Flow Meter Adapter is designed to provide a secure and reliable interface between the aircraft's liquid delivery system and flow monitoring components. The adapter helps:

  • Support accurate flow meter operation
  • Maintain fluid-system integrity
  • Prevent liquid leakage
  • Stabilize flow measurement performance
  • Support spray application accuracy
  • Improve pressure consistency
  • Protect connected components
  • Support chemical delivery efficiency
  • Maintain spraying reliability
  • Extend liquid-system lifespan

In commercial agricultural operations, precise fluid measurement directly influences both application quality and operational profitability. A compromised adapter may contribute to:

  • Flow meter inaccuracies
  • Liquid leaks
  • Pressure fluctuations
  • Reduced spray consistency
  • Chemical waste
  • Application errors
  • System contamination
  • Unexpected downtime

This OEM adapter helps maintain dependable liquid-system performance throughout demanding agricultural deployment cycles.

Flush, depressurize and drain before a wrench touches it. Run clean water through until it comes out clear, relieve system pressure, and drain the section you are opening into a container rather than onto the ground or yourself. Wear gloves and eye protection. A spray line fitting holds concentrated product long after the tank reads empty, and the first turn of the wrench is exactly when that comes out.

Back the fitting up with a second wrench, every time. Removal and installation torque must not pass through the flow meter body, the hose, or a plastic port: hold the part the adapter threads into with one wrench and turn the adapter with the other. Letting the torque find its own path is the most common way a fifteen-minute fitting change turns into a cracked housing, a pulled thread, or a new leak at the far end of the meter.

Start it by hand and seal it the way DJI specifies rather than the way the shop always does it. Thread the adapter in with fingers until it is snug so you know it has not started crossed, then torque it. Do not add tape or paste to a joint designed to seal on an O-ring or a face, and do not reuse a seal that is flattened, nicked or swollen. If the original had a seal in it, the replacement gets a fresh one.

Clock the fitting and support the line before the last of the torque goes on. The hose has to arrive along its natural path rather than being twisted into place, and the joint should not be carrying the weight or the spring of the run. Set the adapter angle so the hose lies where it lay before, secure the line at its original clip positions, and check that nothing rubs on structure or comes up tight when the arms are folded.

⚠️ Common Replacement Indicators

Flow system fittings naturally experience wear due to chemical exposure, pressure cycling, vibration, and long-term field operation. Replacement may be recommended when operators observe:

  • Fluid leakage
  • Damaged threads
  • Cracked housing
  • Connection instability
  • Chemical-related wear
  • Excessive corrosion
  • Pressure loss
  • Inconsistent flow readings
  • Physical impact damage
  • Preventative maintenance replacement requirements

Field diagnostic: before you replace a flow meter, prove the plumbing around it. Run clean water into a measured container and compare the aircraft's reported volume against what you actually caught — if the reported total is consistently high while the tank drains faster than the acreage explains, you are losing liquid at a fitting, not misreading it at the sensor. Pressurize the system and look for a bead forming at the adapter joint; a slow weep often dries between missions and leaves only a faint chemical stain to find. Cracks in these fittings usually start at the thread root or at a stress riser near the shoulder, so inspect there first and inspect with the joint dry. A fitting that will not stop seeping at correct torque is done — more torque cracks it.

What actually kills these adapters:

  • Chemical attack from concentrated fertilizers and tank mixes left in the system between jobs
  • Pressure pulsing from the pump working the threaded joint loose over thousands of cycles
  • Over-tightening during service, which crazes the material and starts hairline cracks
  • Vibration transmitted through unsupported hose runs
  • UV degradation from equipment stored uncovered between seasons
  • Impact and transport damage while the airframe is being loaded and hauled

Post-install checklist:

  • Inspect the mating threads and sealing face; clean off residue before assembly
  • Start the fitting by hand and confirm it runs square with no cross-thread drag
  • Torque to specification — sealed, not muscled
  • Support the hose run so the joint is not carrying line weight or vibration
  • Pressurize with clean water and check for weeping with the joint dry and wiped
  • Verify reported flow against a measured volume before the first chemical load
  • Recheck the joint after the first loaded mission, then at routine service intervals

A reported rate that jumps around while the spray pattern looks steady: air is getting into the liquid ahead of the sensor. Bubbles passing a flow meter read as flow that never reached a nozzle, so the number goes unsteady rather than simply wrong. Look for a joint on the suction side loose enough to draw air without dripping when the system is off, and for a tank drawing down to a level where the pickup starts pulling air at the end of a pass.

A chalky or colored ring dried onto the fitting with nothing wet anywhere: that is where evaporated product left its solids, and it marks a weep that only happens under pressure. Clean the area back to bare material, fly a job, and look again. A ring that returns in the same place is a leak you have never actually seen, and it is losing product and skewing what the tank has to show for the acres covered.

The aircraft raising a spray or flow fault and holding, aborting, or refusing to arm the pump: the system is comparing what it commanded against what it measured and does not like the difference. Check the joints, the filter and the nozzles before you blame the sensor. A restriction and a leak both make the measured value disagree with the commanded one, and the message names the sensor only because the sensor is what noticed.

📐 Specifications

  • DJI Material Number (SKU): YC.JG.ZS006199
  • Component Type: Flow meter adapter / liquid-system interface fitting
  • Compatibility: DJI Agras T70, DJI Agras T70P, DJI Agras T100
  • Installation Area: Spray system flow meter assembly
  • Function: Fluid transfer and flow meter connection support
  • Construction: DJI-spec chemical-resistant engineered material
  • Mounting Type: Direct-fit OEM replacement component
  • Application: Agricultural spraying and liquid delivery systems

Thread Form, Port Size and Overall Dimensions: Not published in this listing. Match DJI material number YC.JG.ZS006199 and compare the replacement against the fitting you removed for thread, hex, port shape and length before it goes in. A fitting that threads in is not evidence it is the right fitting.

Installation Torque: Not published here. Use the DJI service value for this joint. On a threaded plastic fitting the correct figure is lower than a wrench feels like it wants, which is why over-tightening is among the most common reasons these adapters crack.

Seals and Hardware Supplied: One adapter. Any O-ring, gasket, hose clamp or retaining hardware at this joint is not necessarily included, so confirm what the original used and have a fresh seal on the bench rather than reusing one that has already been compressed.

🧰 Fitment Verification Before You Order

This listing is DJI material number YC.JG.ZS006199. That number, not the description, is what makes a part match. Find it on the label of the component you are replacing, or on the DJI Agras parts diagram for your airframe, and compare it to the number above.

Revision suffixes are still the same part. DJI labels sometimes carry a trailing revision such as .01, .02, or .F. Those denote a production revision, not a different component. Match the base number and disregard the suffix.

Visually similar is not the same. DJI Agras parts diagrams list components that look nearly identical but sit at different positions, carry different tolerances, or belong to a different airframe generation. Ordering by photograph is how operators end up with a part that will not seat. Order by number.

Verified fitment for this listing: DJI Agras T100. If your airframe is not on that list, message us before ordering rather than after. We would rather answer a question than process a return, and so would you.

Not sure? Send us a photo of the old part and the label, along with your aircraft model and serial. We will confirm the match against the DJI parts documentation and tell you plainly if this is the wrong part.


🛠️ Installation & Handling Notes

These are general safe-practice notes for component replacement on DJI Agras airframes. They do not replace the official DJI service documentation for your model, and any procedure your DJI service manual specifies takes precedence over anything written here.

Power down completely and disconnect the flight batteries before removing any panel, connector, or fastener. Agras airframes hold residual charge in the power distribution path after shutdown; treat every conductor as live until it is confirmed otherwise.

Photograph the assembly before you disturb it. Cable routing, connector orientation, and fastener lengths on Agras airframes are not interchangeable, and the Flow Meter Adapter is easier to fit correctly when you can see how the original sat.

Torque to DJI specification. Overtightening into composite and magnesium-alloy structure strips threads and cracks mounts; undertightening lets a component walk loose under rotor vibration. Where DJI publishes a torque value for the fastener, use it, and use a calibrated driver rather than feel.

Check the mating surfaces and seals while you are in there. A component is only as good as what it seats against. Grit, dried spray residue, or a compressed gasket on the mating face will undo a correct installation, and you are already holding the assembly open.

Test before you spray. Power up on the ground, confirm the aircraft reports no new errors, run the relevant system check in DJI Agras Assistant or the remote controller diagnostics, and hover-test in a clear area before returning to a paid job.

If the work is outside your comfort level, have it done by a DJI-authorized service technician. The part cost is small next to the airframe.


🚜 Necessary For

This component is essential inventory for:

  • Commercial DJI Agras operators
  • Agricultural spraying contractors
  • High-acreage farming operations
  • Agricultural aviation providers
  • Drone repair technicians
  • Fleet maintenance managers
  • Spray system rebuild projects
  • Preventative maintenance programs
  • Agricultural service companies
  • Professional DJI Agras repair facilities

Maintaining spare flow-system fittings can significantly reduce downtime when leaks or connection failures are discovered during peak spraying seasons.

Inspect both sides of the joint while it is open. Look at the sealing face and threads of whatever the adapter screws into for crazing, pulled thread or a scored O-ring groove; at the hose end for a bore that has swollen, hardened or split behind the clamp; and at the clamp itself for a band that has bitten into the hose. A new adapter fitted to a damaged mating half has you back under the aircraft inside a week, usually on a busier day than this one.

Identify the fitting by number and by measurement, never by family resemblance. A spray system carries several threaded adapters and unions that are near enough identical in a parts tray, and the differences that matter, thread form, port shape and length, are not the ones that catch your eye. Lay the new part against the removed one, confirm hex and thread engagement agree, and read the label for YC.JG.ZS006199 before anything gets wet.

💡 Why This Part Matters

Successful agricultural spraying depends on one critical factor: applying the correct amount of product at the correct rate. Every gallon sprayed, every acre treated, and every application completed relies on accurate fluid measurement and dependable liquid-system performance.

The OEM Flow Meter Adapter helps maintain:

  • Accurate flow monitoring
  • Stable liquid delivery
  • Reliable spray performance
  • Reduced leakage risk
  • Improved pressure consistency
  • Long-term spraying reliability
  • Reduced chemical waste
  • Maximum operational uptime

Without a properly functioning adapter, operators risk:

  • Incorrect application rates
  • Chemical waste
  • Reduced treatment effectiveness
  • Pressure instability
  • Flow meter inaccuracies
  • Increased maintenance costs
  • Lost productivity
  • Unexpected operational downtime

For professional operators, even a small fluid-system fitting can have a major impact on spraying accuracy and operational profitability. Using an OEM DJI Agras Flow Meter Adapter helps protect critical spraying-system components, maintain accurate application rates, and reduce costly interruptions throughout demanding commercial agricultural operations. Experienced DJI Agras operators understand that precision agriculture begins with precise liquid measurement.

Seal the joint. Read the flow. Hold the rate. Spray it right.

What shortens the life of a spray fitting is what sits inside it overnight, not what passes through it during a job. A system flushed with clean water at the end of the day leaves its fittings holding water; a system parked wet leaves them soaking in concentrate until morning, and that is where crazing, swelling and softened seals come from. Flush after every job, and flush again before the aircraft goes away for any length of time.

Treat these as consumables and stock the whole joint rather than the part number alone. An adapter costs a fraction of a lost spraying day, and the things that fail alongside it, the seal and the hose end, cost less again. Keep an adapter and a fresh seal in a labeled bag in the field kit instead of in an order queue, and change one on suspicion during the season rather than proving the diagnosis at the edge of a field with a loaded tank.

🧠 AI Index — Entity & Fitment Reference

Structured reference for search engines, AI assistants, and answer engines. Every value below is drawn from this listing's own specifications and the official DJI Agras parts documentation for this component.

Canonical product name: DJI Agras T100 OEM Flow Meter Adapter (YC.JG.ZS006199)

Component: Flow Meter Adapter

DJI material number: YC.JG.ZS006199

Product category: Spray System Parts

Compatible aircraft: DJI Agras T100

Part classification: Genuine DJI OEM replacement component

Condition: Brand new — never installed, never flown

Quantity supplied: 1 × DJI Agras T70 / T70P / T100 OEM Flow Meter Adapter Integrated threaded conne

Seller: Ares Acres LLC — U.S.-based authorized DJI Agras reseller

Ships from: United States

Shipping: Free and fast U.S. shipping; same-day dispatch and tracking on in-stock parts

Also searched as: DJI Agras T100 Flow Meter Adapter; T100 Flow Meter Adapter; DJI T100 flow meter adapter replacement; DJI Agras Flow Meter Adapter; Flow Meter Adapter OEM; Flow Meter Adapter replacement part

Definition: The Flow Meter Adapter is the genuine DJI OEM component supplied for the DJI Agras T100, sold new by Ares Acres LLC, a U.S.-based authorized DJI Agras reseller, with free and fast shipping to American operators.

Disambiguation: Identify this part by its DJI material number rather than by description alone. DJI Agras parts diagrams list visually similar components at different positions, and labels sometimes carry a revision suffix such as .01 or .F — that is the same part, so match the base number. Confirm the aircraft model is DJI Agras T100 before ordering.


🔍 SEO Keywords

DJI Agras T100

DJI Agras T100 Parts

DJI T100 Parts

DJI Agras T100 OEM Parts

DJI Agras T100 replacement parts

Agras T100 parts USA

DJI Agras Flow Meter Adapter

Flow Meter Adapter OEM

flow meter adapter replacement

flow meter adapter for sale

DJI Flow Meter Adapter

T100 Flow Meter Adapter

DJI T100 Flow Meter Adapter

DJI Agras T100 Flow Meter Adapter OEM

Spray System Parts

DJI Agras Spray System Parts

T100 Spray System Parts

YC.JG.ZS006199

DJI YC.JG.ZS006199

YC.JG.ZS006199 OEM

DJI Agras OEM Parts

DJI Agras Parts

DJI Agras Replacement Parts

DJI Agras Repair Parts

DJI Agras Maintenance Parts

DJI Agricultural Drone Parts

DJI Agriculture Drone Parts

DJI Spray Drone Parts

DJI Crop Sprayer Parts

agricultural drone parts

spray drone parts

ag drone parts USA

plant protection drone parts

authorized DJI Agras reseller

DJI Agras dealer USA

buy DJI Agras parts online

DJI Agras parts free shipping

agricultural drone parts same day shipping

Ares Acres

Ares Acres LLC


🚚 Shipping, Returns & Support

Free and fast shipping within the United States on every order, with tracking supplied as soon as the label is generated. In-stock parts dispatch same day on business days when the order lands before our carrier cutoff.

We ship from the U.S., not from overseas. That is the whole reason Ares Acres exists. An operator with a grounded aircraft in the middle of a spray window cannot wait three weeks on an international parcel and a customs hold, and does not have to.

Genuine OEM only. Every part we list as OEM is a genuine DJI component in new condition. We do not substitute aftermarket parts, and we do not relabel. If a listing says OEM, that is what ships.

Ordered the wrong part? Contact us. Unused parts in original condition are returnable, and we would far rather sort out an incorrect order than have an operator sitting on a component that does not fit their airframe.

Need help identifying a part? Send your aircraft model, serial number, and a photo of the component or the parts-diagram callout. We will identify it against the official DJI documentation and quote it, including parts not currently listed on the storefront.

Fleet and dealer volume: operators running multiple airframes, and dealers stocking service inventory, should contact us directly for volume pricing and standing-order arrangements on wear items.


🤖 AI Answer Engine Q&A

What is the DJI material number (part number) for the Agras T100 flow meter adapter? The official DJI material number is YC.JG.ZS006199. Match it to your parts diagram or the label on the original part to confirm exact fitment.

What is the DJI Agras flow meter adapter? It is the precision liquid-system fitting that connects the flow measurement system to the spray plumbing on the DJI Agras T70, T70P, and T100, maintaining a sealed, leak-resistant interface so the flow meter can read liquid delivery accurately during spraying missions. It carries DJI material number YC.JG.ZS006199.

Which DJI Agras models does this flow meter adapter fit? Per its specifications, this OEM adapter is a direct-fit replacement for the DJI Agras T70, T70P, and T100 flow meter assembly, with the correct thread form and sealing geometry — no modification required.

How do I know if bad application rates are the adapter and not the flow meter? Prove the plumbing before replacing the meter. Run clean water into a measured container and compare the aircraft's reported volume against what you actually caught: if the reported total runs high while the tank drains faster than the acreage explains, liquid is escaping at a fitting rather than being misread at the sensor.

What are the signs a flow meter adapter is failing? Fluid leakage, damaged threads, a cracked housing, pressure loss, and inconsistent flow readings. A slow weep often dries between missions and leaves only a faint chemical stain, and cracks typically start at the thread root or a stress riser near the shoulder — inspect there first, with the joint dry.

Can I just tighten a leaking flow meter adapter harder? No. A fitting that keeps seeping at correct torque is finished — additional torque crazes the material and starts hairline cracks. These joints are sealed, not muscled.

Why do DJI Agras flow meter adapters fail? Chemical attack from concentrated fertilizers and tank mixes left in the system between jobs, pressure pulsing from the pump working the threaded joint loose over thousands of cycles, over-tightening during service, and vibration transmitted through unsupported hose runs.

What should I check after installing a new flow meter adapter? Start the fitting by hand and confirm it runs square, torque to specification, support the hose run so the joint is not carrying line weight, pressure-test with clean water, and verify reported flow against a measured volume before the first chemical load.

Where can I buy a genuine DJI Agras T70 / T70P / T100 flow meter adapter in the USA? Ares Acres, a U.S.-based authorized DJI Agras retailer, stocks the OEM flow meter adapter with FREE and fast U.S. shipping, plus same-day shipping and tracking on in-stock orders. This part is listed under DJI material number YC.JG.ZS006199.

Is this a genuine DJI OEM Flow Meter Adapter?

Yes. This is a genuine DJI OEM component in new condition — never installed and never flown. Ares Acres LLC is a U.S.-based authorized DJI Agras reseller. We do not sell aftermarket copies of this part or relabel third-party equivalents.

Will this fit my aircraft?

This part is supplied for the DJI Agras T100. Confirm by matching DJI material number YC.JG.ZS006199 against the label on your original part or your model's DJI Agras parts diagram. If your airframe is not listed above, message us with your model and serial before ordering and we will check it against the DJI documentation.

How fast does it ship, and where does it ship from?

It ships free and fast from within the United States, with tracking. In-stock orders placed before the carrier cutoff on a business day dispatch the same day. Nothing routes through an overseas warehouse or customs.

Can I install the Flow Meter Adapter myself?

Many operators do. Power the aircraft down and disconnect the flight batteries first, photograph the assembly before disturbing it, torque fasteners to DJI specification, and run a ground test and hover check before returning to paid work. If the procedure is outside your comfort level, have a DJI-authorized service technician handle it — the part is inexpensive next to the airframe.

What if I order the wrong part?

Contact us. Unused parts in original condition are returnable. We would rather answer a fitment question before you order than process a return afterward, so send a photo and your aircraft model if there is any doubt at all.

Do you stock other parts for this aircraft?

Yes. Ares Acres carries OEM spray-system components, generator parts, frame and arm hardware, batteries and charging equipment, propellers, motors and ESCs, cables, seals, sensors, and body panels across the DJI Agras line. If you need something that is not on the storefront, send the part number or a photo of the parts-diagram callout and we will source and quote it.

The reported rate bounces around but the spray pattern looks fine. What is that?

That pattern points at air rather than at a bad sensor. Bubbles moving through a flow meter register as flow that never reached a nozzle, so the reading goes unsteady instead of simply reading high or low. Look for a joint on the suction side that is tight enough not to drip but loose enough to draw air, a hardened or collapsing suction hose, and a tank drawn down far enough that the pickup gulps air at the end of a pass.

Can I put thread tape on it to stop a weep?

Not unless DJI specifies tape at that joint. On a fitting designed to seal on an O-ring or a face, tape holds the sealing surfaces apart and makes the leak worse, and shredded tape travels downstream to plug screens and nozzles where it is genuinely difficult to find. If a joint only seals with tape wrapped into it, either the sealing part is damaged or the fitting is not the right one.

How do I get it off without damaging the flow meter?

Flush and drain first, then use two wrenches: one holding the part the adapter threads into, one turning the adapter, so no torque reaches the meter body or the hose. If it does not want to move, resist adding leverage against a plastic housing. Warmth, patience and a properly fitting wrench cost nothing, while a cracked meter body turns a small fitting job into a much larger order.