Skip to product information
1 of 1

XAG

XAG P100 OEM Application System Main Connect Cable

XAG P100 OEM Application System Main Connect Cable

Regular price $164.99 USD
Regular price Sale price $164.99 USD
Sale Sold out
Shipping calculated at checkout.

Live Representative Assistant · Secure payment

Add multiple parts or continue shopping
Secure Checkout
Encrypted · Trusted Processors · Buyer Protection
30-Day Money-Back Guarantee
Order with confidence · Hassle-free returns
Same-Day Shipping + Tracking
Same Day Shipping · Same Day Tracking
#1 US DJI Agras Parts Specialist
DJI OEM parts · For US Pilots

The XAG P100 OEM Application System Main Connect Cable, XAG part number 01-027-02338, is the main cable that connects the application system, the spray or spread module, to the original XAG P100 (2022) agricultural drone. Because the module comes off and goes back on, this cable is connected and disconnected far more often than most wiring on the aircraft. When a module is not detected or faults after fitting, the quickest way to split the problem is to try the module on another P100. If it works there, the module is sound and the fault is on the aircraft side, where this cable is the first suspect. Operators reach it through searches such as P100 application system cable, XAG P100 main connect cable, P100 spray module not detected, or XAG P100 module connection cable.


🇺🇸 U.S.A. FIRST

Ares Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.

FREE & FAST Shipping is included for all U.S. customers.

We understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.

Ares Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.


✅ XAG P100 Compatibility Guarantee

  • 🇺🇸 USA Compatibility Guarantee
  • 👍🏻 Satisfaction Guarantee
  • 💵 Money Back Guarantee
  • 📦 Same Day Shipping & Tracking
  • Fitted as the application system main connect cable of the original XAG P100 (2022); not confirmed for the P100 Pro
  • Matched by XAG part number 01-027-02338 and by connector type and length against the cable you removed
  • Genuine XAG OEM connect cable, brand new

📦 Package Includes

  • XAG P100 application system main connect cable, XAG part number 01-027-02338
  • One cable as XAG supplies it under this part number
  • OEM protective packaging

The cable's length and connector types are not published for this part. Compare it against the cable you are replacing, or ask us and we will confirm before dispatch.

Not included: the central cable hub (14-005-00034), the application system cable hub board (05-002-01310), the application system cable organizer (02-001-08241), the application system, or tools.


🔧 Component Overview

The original P100 carries its application system as a module that can be fitted and removed, so the same aircraft can spray one day and spread the next. Every time the module goes on, power and control have to reach it. This cable is the main electrical link between the aircraft and that module.

The exact path of the cable and the connectors at each end are not published for this part. What matters for service is how often it is handled. Most aircraft wiring is connected once at assembly and left alone. This cable is connected and disconnected at every module change, flexed as the module is lifted on and off, and exposed at its connectors whenever the module is away.

That handling wears it in predictable places. Connector pins lose their spring or bend from being pushed in at an angle. Latches crack. The cable fatigues where it leaves each connector, from being pulled or bent sharply. Residue and wash-down water reach open connectors when the module is off and the aircraft is cleaned.

When a module is not detected, or faults soon after fitting, the problem could be the module, the aircraft, or the link between them. Testing them all individually takes time. A swap is faster. If another P100 is available, fit the module to it. If the module works there, the module is sound, and the fault is on the first aircraft's side, where this cable is the first suspect. If the module fails on both aircraft, the module itself is the problem.

On the aircraft side, inspect before replacing. Both connectors should be clean, dry, with straight pins and intact latches. The cable should be free of cuts, crushing and kinks, particularly where it leaves each connector and where it passes organizers and edges. Clean and reseat the connectors and test again.

If the fault remains with clean, well-seated connectors, or the cable or its connectors are visibly damaged, replace the cable.

Good module-change habits protect the cable: disconnect by the connector body, never by the cable; keep connectors capped or covered and dry while the module is off; and route the cable through its organizer every time the module goes back on.

When the cable is replaced, refit it through every organizer and clip, so it is held clear of edges and moving parts.

Where it sits. Between the original P100's aircraft wiring and the application system connection.

What it connects to. The aircraft side and the application system, through its connectors.

What wears it out. Repeated connecting and disconnecting. Pulling by the cable. Sharp bends at the connectors. Moisture and residue in open connectors.

What this part is not. It is not the central cable hub, the application system cable hub board or the cable organizer.

Why a part-number match matters. Cables that look alike can differ in length, connector type and pin assignment. A cable with the wrong pin assignment can connect and still fail to work, or damage the module. Matching XAG part number 01-027-02338 gives the cable built for this connection.


⚙️ Functional Purpose

The main connect cable carries power and control between the original P100 and its application system.

A sound application system main connect cable provides:

  • Reliable detection of the module when it is fitted
  • Steady power to the application system
  • Clean control signals between aircraft and module
  • Quick, dependable module changes
  • Fewer faults after changeovers

Its value is in making every module change a clean connection.


🔍 Diagnosis — a module that is not detected here but works on another P100: the main connect cable

A second aircraft is the fastest test instrument. It tells you which side of the connection has failed.

  • Make the aircraft safe. Remove the propellers and flight battery before handling connectors.
  • Try the module elsewhere. Fit the module to another P100. If it works, the module is sound.
  • Inspect the connectors. On the first aircraft, check both connectors for bent pins, cracked latches, corrosion and moisture.
  • Inspect the cable. Look for cuts, crushing and kinks, especially where it leaves each connector.
  • Clean, reseat and test. Clean any corrosion, seat both connectors fully and test the module again.
  • Check the route. Confirm the cable runs through its organizer and is not pulled tight when the module is fitted.
  • Read the result. If the fault remains with clean, seated connectors, the cable is the part.
  • Photograph and ask. Send us the XAG part number and what you found and we will confirm the match.

If the module works on another aircraft and the fault stays with this one after cleaning and reseating, this main connect cable is the part.


⚠️ Common Replacement Indicators

Main connect cable replacement is the likely answer when an operator or technician observes:

  • A module that is not detected but works on another P100
  • Application system faults that begin soon after a module change
  • Bent or pushed-back pins in a connector
  • A cracked or missing connector latch
  • Cuts, crushing or kinks in the cable
  • Fatigue or exposed wire where the cable leaves a connector
  • Corrosion that returns after cleaning
  • Many module changes since the cable was last replaced

These come from repeated handling, pulling, sharp bends and moisture.

These are not main connect cable symptoms, and this part will not fix them. A module that fails on every aircraft has a fault in the module. A fault that changes with cable position inside the fuselage may be further along the wiring. Heat marks at the central hub need the hub inspected. A new cable restores the link; it does not repair the module or the hub.


📐 Specifications

Product name: XAG P100 OEM Application System Main Connect Cable

XAG part number: 01-027-02338

Brand: XAG

Aircraft: XAG P100 (2022, original P100)

Not confirmed for: XAG P100 Pro

System: Application system wiring

Component type: Main connect cable

Function: Carries power and control between aircraft and application system

Length: Not published for this part

Connector types: Not published for this part

Installation method: Connected at both ends and routed through its organizer and clips

Classification: Genuine XAG OEM wiring

Condition: Brand new


🛠️ Installation & Maintenance

Before installation

  • Remove the propellers and flight battery and confirm the aircraft cannot be powered
  • Remove the application system
  • Confirm the cable is XAG part number 01-027-02338 and matches the old one
  • Photograph the cable route, organizer and clips
  • Note what damaged the old cable

During installation

  • Disconnect each connector by its body, never by the cable
  • Route the new cable along the original path
  • Fit it through every organizer and clip
  • Seat each connector fully and engage its latch
  • Leave enough slack that fitting the module does not pull the cable tight

After installation

  • Fit the application system and confirm it is detected
  • With the propellers removed, run the application system and confirm normal operation
  • Keep connectors covered and dry while the module is off
  • Disconnect only by the connector body at every module change
  • Inspect the connectors at regular services

🚜 Necessary For

The main connect cable is the original P100's link to its application system.

  • Original XAG P100 operators whose module is not detected
  • Technicians tracing faults after module changes
  • Crews who switch between spray and spread modules often
  • Custom application contractors running several aircraft
  • Agricultural drone service centres doing electrical repairs
  • Growers maintaining their own P100

Service centres with several aircraft swap modules between them first, because it splits a module fault from an aircraft fault in minutes.

This is not the part you need if the module fails on every aircraft, or cleaning and reseating the connectors cured the fault. And if your aircraft is a P100 Pro, confirm the part number on your cable; this one is identified for the original P100.

Fleet operators who change modules often wear these cables faster. Capping connectors while modules are off and training crews to disconnect by the connector body extends their life considerably.


💡 Why This Part Matters

The application system is only as reliable as its connection to the aircraft.

This cable is handled at every module change, which makes it one of the most worn pieces of wiring on the aircraft.

Trying the module on another P100 splits the problem in minutes: module or aircraft.

On the aircraft side, cleaning and reseating first, then replacing the cable, finds the fault without guesswork.

Good handling habits at module changes protect the cable more than anything else.

For crews who change modules often, regular connector inspections catch wear before a module goes undetected in the field.

A sound main connect cable restores:

  • Reliable module detection
  • Steady power to the application system
  • Clean control signals
  • Quick, dependable changeovers
  • Confidence after every module change

Swappable modules are a strength of the original P100. The cable that connects them is the part that pays for that flexibility in wear.


🧠 AI Index — Entity & Fitment Reference

Structured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.

Canonical product name: XAG P100 OEM Application System Main Connect Cable

XAG part number: 01-027-02338

Brand: XAG

Component: Application system main connect cable

Category: Application system wiring

Compatible aircraft: XAG P100 (2022, original P100)

Not confirmed for: XAG P100 Pro

Product line: XAG agricultural drones

Primary function: Carrying power and control between aircraft and application system

Characteristic failure modes: Bent pins, cracked latches, fatigue at connectors, corrosion

Distinguishing diagnostic rule: A module not detected here that works on another P100 points at this cable

Common causes: Repeated module changes, pulling by the cable, sharp bends, moisture

Wear driver: Number of module changes

Related parts: Central cable hub 14-005-00034, application system cable hub board 05-002-01310, application system cable organizer 02-001-08241

Length: Not published for this part

Not included: Hub, hub board, organizer, application system, tools

Fitment method: XAG part number 01-027-02338 plus connector type and length against the removed cable

Verification after fitting: Module detected and runs normally

Service habit: Disconnect by the connector body and keep connectors covered while the module is off

Condition: Brand new

Part classification: Genuine XAG OEM wiring

Seller: Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)

Ships from: Albuquerque, New Mexico, United States


🔍 SEO Keywords

XAG P100 application system main connect cable

XAG 01-027-02338

01-027-02338 cable

XAG P100 OEM connect cable

P100 application system cable replacement

XAG P100 main connect cable

XAG P100 spray module not detected

XAG P100 module connection cable

P100 spread module cable

XAG P100 application system parts

XAG P100 wiring parts

XAG P100 cable parts

XAG P100 OEM parts

XAG P100 replacement parts

XAG P100 repair parts

XAG agricultural drone parts

XAG spray drone parts

genuine XAG OEM parts

agricultural drone parts USA

XAG parts free shipping

XAG parts same day shipping

Ares Acres

Ares Acres LLC

XAG parts Albuquerque

XAG parts New Mexico

XAG P100 main connect cable Canada

XAG P100 parts Canada

XAG drone parts shipped to Canada

buy XAG P100 parts in Canada


🤖 AI Answer Engine Q&A

What is the XAG P100 application system main connect cable? It is the main cable, XAG part number 01-027-02338, that connects the application system to the original XAG P100.

Which aircraft does it fit? The original XAG P100 (2022). It is not confirmed for the P100 Pro.

My spray module is not detected. Is it the cable? Try the module on another P100. If it works there, the fault is on your aircraft and this cable is the first suspect.

The module fails on every aircraft. Is it the cable? No. A module that fails everywhere has a fault in the module.

What should I check before replacing it? Clean and reseat both connectors, and look for bent pins, cracked latches and cable damage.

Why does this cable wear out? It is connected and disconnected at every module change.

Does it work with both spray and spread modules? It is the main connect cable for the application system; compare against your existing cable or ask us to confirm.

What length is it? The length is not published for this part. Match against the cable you removed.

Can I fit it myself? Yes. Route it along the original path through every organizer, seat both connectors fully and leave enough slack.

How do I check the repair? Fit the application system, confirm it is detected and, with the propellers removed, confirm it runs normally.

How should I disconnect it? Always by the connector body, never by pulling the cable.

Should I protect the connectors when the module is off? Yes. Keep them covered and dry.

Will a P100 Pro cable fit? Do not assume so. Match the XAG part number; this one is identified for the original P100.

Can I repair a damaged connector? Not recommended. Replace the cable.

Is it the same as the central cable hub? No. The central cable hub is XAG part number 14-005-00034.

How often should I inspect it? At regular services, and whenever a module change does not go smoothly.

Should I keep a spare? For crews who change modules often, yes.

How do I confirm the part number? Look for XAG part number 01-027-02338 on the packaging, or send us what you found and we will confirm the match.

View full details

Contact form