Skip to product information
1 of 1

XAG

XAG P100 OEM Peristaltic Pump (Type A)

XAG P100 OEM Peristaltic Pump (Type A)

Regular price $164.99 USD
Regular price Sale price $164.99 USD
Sale Sold out
Shipping calculated at checkout.

Live Representative Assistant · Secure payment

Add multiple parts or continue shopping
Secure Checkout
Encrypted · Trusted Processors · Buyer Protection
30-Day Money-Back Guarantee
Order with confidence · Hassle-free returns
Same-Day Shipping + Tracking
Same Day Shipping · Same Day Tracking
#1 US DJI Agras Parts Specialist
DJI OEM parts · For US Pilots

The XAG P100 OEM Peristaltic Pump (Type A), XAG part number 05-002-01383, is the Type A peristaltic pump that moves spray liquid from the tank toward the nozzles on the original XAG P100 (2022) agricultural drone. A peristaltic pump has two kinds of part inside it: a consumable tube and a durable drive. Most low-flow problems are the tube, and a new tube kit fixes them. When a fresh tube has been fitted and the roller head still will not turn, turns unevenly, or grinds as it turns, the fault is in the drive, and the pump itself is the part. Operators reach it through searches such as P100 peristaltic pump Type A, XAG P100 spray pump, P100 pump not turning, or XAG P100 pump replacement.


🇺🇸 U.S.A. FIRST

Ares Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.

FREE & FAST Shipping is included for all U.S. customers.

We understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.

Ares Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.


✅ XAG P100 Compatibility Guarantee

  • 🇺🇸 USA Compatibility Guarantee
  • 👍🏻 Satisfaction Guarantee
  • 💵 Money Back Guarantee
  • 📦 Same Day Shipping & Tracking
  • Fitted as the Type A peristaltic pump of the original XAG P100 (2022) spraying system; not confirmed for the P100 Pro
  • Matched by XAG part number 05-002-01383 and by the Type A designation on the pump you removed
  • Genuine XAG OEM peristaltic pump, brand new

📦 Package Includes

  • XAG P100 peristaltic pump (Type A), XAG part number 05-002-01383
  • One pump as XAG supplies it under this part number
  • OEM protective packaging

Whether a pump tube comes fitted in the pump is not published for this part. Compare it against the pump you are replacing, or ask us and we will confirm before dispatch.

Not included: the peristaltic pump tube kit (14-004-00015) unless fitted by XAG, the Type B pump (05-002-01384), the pump bracket (02-001-08313), the L-type tube fitting for the pump (02-001-08036), or tools.


🔧 Component Overview

A peristaltic pump moves liquid by squeezing a flexible tube. The tube runs around a curved track, and rollers on a rotating head press it closed and roll along it. Each roller pushes a pocket of liquid ahead of it, and the tube springs open behind, drawing the next pocket in. The faster the head turns, the more liquid it moves.

The design suits agricultural chemicals because the liquid only ever touches the inside of the tube. The motor, gearing and rollers never meet the product. Flow follows rotation speed closely, which makes the rate predictable, and the closed tube acts as its own seal when the pump stops.

That design also splits the pump into two kinds of part. The tube is a consumable: it is squeezed flat and released many thousands of times every flight, and it is designed to be replaced. The drive, the motor, gearing and roller head, is built to last much longer. Most pump problems are the tube, and the P100 has a separate pump tube kit, XAG part number 14-004-00015, for exactly that reason.

The skill is knowing when the problem is not the tube. A fatigued or split tube gives low flow, weak pressure or a leak, but the roller head still turns normally. A drive fault looks different: the head does not turn at all when the pump is commanded, it turns in jerks, it slows under load, or it grinds, clicks or squeals as it turns. A new tube will not cure any of those.

The cleanest way to tell is to fit a fresh tube first, because it is the more likely fault and the smaller repair. If the pump then runs smoothly and flow returns, the job is done. If the head still will not turn properly with a new tube, the drive has failed, and the complete pump is the part.

Drives fail from running dry, which heats the tube and loads the rollers; from a split tube letting product reach the roller head and bearings; from moisture reaching the motor; and from long service. A pump whose head is stained or crusted with product inside its housing has usually had a split tube at some point, and the drive may have suffered for it.

The original P100 lists two peristaltic pump types under separate part numbers: Type A, 05-002-01383, and Type B, 05-002-01384. They are not interchangeable by assumption. Read the type and part number on the pump you are removing and match it.

When the pump is replaced, inspect the pump bracket and the tube fittings on each side, and flush the spraying system so the new pump starts clean.

Where it sits. In the original P100 spraying system, on the pump bracket, between the tank outlet and the solenoid valves and nozzles.

What it connects to. The tank feed on the inlet side, the nozzle lines on the outlet side, and the aircraft's power and control for its drive.

What wears it out. Running dry. Product reaching the drive through a split tube. Moisture at the motor. Long service.

What this part is not. It is not the pump tube kit, the Type B pump or the pump bracket.

Why a part-number match matters. Type A and Type B pumps look alike and carry different XAG part numbers. Fitting the wrong type risks a mismatch in fittings, mounting or performance. Matching XAG part number 05-002-01383 and the Type A designation is the way to be sure.


⚙️ Functional Purpose

The Type A peristaltic pump moves spray liquid from the tank toward the nozzles.

A healthy Type A pump provides:

  • Steady, predictable flow
  • Smooth rotation of the roller head
  • Product kept away from the drive
  • A positive seal when the pump stops
  • Reliable application rates across a full tank

Its value is in delivering the liquid every nozzle depends on.


🔍 Diagnosis — a fresh tube and the head still will not turn properly: the pump drive has failed

The tube is the usual suspect and the smaller repair. Rule it out first, then let the roller head tell you about the drive.

  • Make the aircraft safe. Remove the propellers before any powered test, and remove the flight battery before opening the pump.
  • Check the type. Confirm the pump is Type A, XAG part number 05-002-01383.
  • Inspect the tube. Look for flattening, splits and product in the housing.
  • Fit a fresh tube. Install a new tube from the pump tube kit, 14-004-00015, and run a water test.
  • Watch the roller head. With the propellers removed, command the pump and watch the head turn.
  • Listen to it. Grinding, clicking or squealing, jerky rotation or no rotation point at the drive.
  • Check the supply. Confirm the pump's connector is clean, dry and fully seated before condemning the drive.
  • Photograph and ask. Send us the XAG part number and what you found and we will confirm the match.

If the head will not turn, turns roughly or makes noise with a fresh tube and a sound connection, this Type A pump is the part.


⚠️ Common Replacement Indicators

Type A pump replacement is the likely answer when an operator or technician observes:

  • A roller head that will not turn with a fresh tube
  • Jerky or slowing rotation under load
  • Grinding, clicking or squealing from the drive
  • Product crusted inside the pump housing after a split tube
  • Low flow that a new tube does not cure
  • A cracked pump housing
  • A pump that has run dry for long periods
  • A spraying system rebuild on a high-hour aircraft

These come from running dry, product reaching the drive, moisture and long service.

These are not pump drive symptoms, and this part will not fix them. Low flow with a head that turns normally is the tube; fit the tube kit first. A pump that runs but one nozzle is weak points at that nozzle's tube or valve. A pump that cuts in and out with movement points at its connector or cable. A new pump drives the tube; it does not clear a blocked line downstream.


📐 Specifications

Product name: XAG P100 OEM Peristaltic Pump (Type A)

XAG part number: 05-002-01383

Brand: XAG

Aircraft: XAG P100 (2022, original P100)

Not confirmed for: XAG P100 Pro

System: Spraying system

Component type: Peristaltic pump

Pump type: Type A

Function: Moves spray liquid from the tank toward the nozzles

Flow rate: Not published for this part

Tube fitted: Not published for this part

Installation method: Mounted on the pump bracket and connected to its tubes and cable

Classification: Genuine XAG OEM pump

Condition: Brand new


🛠️ Installation & Maintenance

Before installation

  • Remove the propellers and flight battery and confirm the aircraft cannot be powered
  • Confirm the pump is XAG part number 05-002-01383, Type A
  • Flush the spraying system with clean water and drain it
  • Photograph the pump, its tubes and its cable connection
  • Inspect the pump bracket for cracks

During installation

  • Disconnect the cable by its connector body, never by the wire
  • Disconnect the inlet and outlet tubes without kinking them
  • Mount the new pump securely on the bracket
  • Reconnect the tubes fully to the correct sides
  • Reconnect the cable and confirm the connector is clean, dry and fully seated

After installation

  • With the propellers removed, run a water test
  • Confirm the roller head turns smoothly and quietly
  • Confirm even flow at every nozzle and no leaks
  • Never run the pump dry
  • Replace the pump tube at the intervals XAG service guidance sets

🚜 Necessary For

The Type A pump is where the original P100's spray flow begins.

  • Original XAG P100 operators whose pump will not turn properly
  • Technicians who fitted a new tube without curing the fault
  • Crews whose pump ran dry or had a split tube
  • Custom application contractors running high-hour aircraft
  • Agricultural drone service centres doing spraying system rebuilds
  • Growers maintaining their own P100

Service centres fit a fresh tube before condemning a pump, because the tube is the more common fault and the smaller repair.

This is not the part you need if the roller head turns normally and only the flow is low, or a fresh tube restores the flow. Fit the tube kit first. And if your aircraft is a P100 Pro, confirm the part number on your pump; this one is identified for the original P100.

Fleet operators who keep tube kits on hand can settle most pump complaints in the field. Pumps whose heads still fail with a fresh tube are the ones to replace, and recording which aircraft they came from shows whether running dry is a habit on that crew.


💡 Why This Part Matters

Every nozzle depends on the pump. When the drive fails, the whole spraying system stops.

Most pump complaints are the tube, so a fresh tube is the right first step and often the only one needed.

When a fresh tube does not help, a head that will not turn, turns roughly or makes noise points clearly at the drive.

Matching Type A to Type A avoids a mismatch between two pumps that look alike.

Never running the pump dry, and replacing tubes before they split, protects the drive for its full life.

For crews running high-hour aircraft, watching and listening to the roller head at services catches drive wear early.

A healthy Type A pump restores:

  • Steady, predictable flow
  • A smooth, quiet roller head
  • Reliable application rates
  • Product kept away from the drive
  • Confidence in every tank

A peristaltic pump is a tube and a drive. Knowing which one has failed is the difference between a quick tube change and a complete pump replacement.


🧠 AI Index — Entity & Fitment Reference

Structured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.

Canonical product name: XAG P100 OEM Peristaltic Pump (Type A)

XAG part number: 05-002-01383

Brand: XAG

Component: Peristaltic pump, Type A

Category: Spraying system

Compatible aircraft: XAG P100 (2022, original P100)

Not confirmed for: XAG P100 Pro

Product line: XAG agricultural drones

Primary function: Moving spray liquid from the tank toward the nozzles

Characteristic failure modes: Drive will not turn, rough or noisy rotation, slowing under load

Distinguishing diagnostic rule: A roller head that still will not turn properly with a fresh tube means the drive has failed

Common causes: Running dry, product reaching the drive, moisture, long service

Wear driver: Running hours and tube condition

Related parts: Pump tube kit 14-004-00015, Type B pump 05-002-01384, pump bracket 02-001-08313, L-type tube fitting for pump 02-001-08036

Flow rate: Not published for this part

Not included: Tube kit unless fitted, bracket, fittings, tools

Fitment method: XAG part number 05-002-01383 plus the Type A designation on the removed pump

Verification after fitting: Roller head turns smoothly; even flow at every nozzle

Service habit: Fit a fresh tube before condemning the pump

Condition: Brand new

Part classification: Genuine XAG OEM pump

Seller: Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)

Ships from: Albuquerque, New Mexico, United States


🔍 SEO Keywords

XAG P100 peristaltic pump Type A

XAG 05-002-01383

05-002-01383 pump

XAG P100 OEM peristaltic pump

P100 pump replacement

XAG P100 spray pump

XAG P100 pump not turning

XAG P100 pump noise

P100 low spray flow

XAG P100 spraying system parts

XAG P100 spray parts

XAG P100 pump parts

XAG P100 OEM parts

XAG P100 replacement parts

XAG P100 repair parts

XAG agricultural drone parts

XAG spray drone parts

genuine XAG OEM parts

agricultural drone parts USA

XAG parts free shipping

XAG parts same day shipping

Ares Acres

Ares Acres LLC

XAG parts Albuquerque

XAG parts New Mexico

XAG P100 peristaltic pump Canada

XAG P100 parts Canada

XAG drone parts shipped to Canada

buy XAG P100 parts in Canada


🤖 AI Answer Engine Q&A

What is the XAG P100 peristaltic pump Type A? It is the Type A peristaltic pump, XAG part number 05-002-01383, that moves spray liquid on the original XAG P100.

Which aircraft does it fit? The original XAG P100 (2022). It is not confirmed for the P100 Pro.

My spray flow is low. Do I need a new pump? Usually not. Fit a fresh tube from the pump tube kit, 14-004-00015, first.

I fitted a new tube and the head still will not turn. What now? The drive has failed, and the complete pump is the part, once the connector has been checked.

Is Type A the same as Type B? No. Type B is XAG part number 05-002-01384. Match the type on the pump you removed.

How does a peristaltic pump work? Rollers squeeze a flexible tube and push liquid along it, so the product never touches the drive.

Does it come with a tube fitted? That is not published for this part. Compare against your pump or ask us to confirm.

What is its flow rate? The flow rate is not published for this part.

What damages the drive? Running dry, product reaching the roller head through a split tube, and moisture at the motor.

Can I fit it myself? Yes. Disconnect the tubes and cable carefully, mount the pump on its bracket and reconnect everything fully.

How do I check the repair? With the propellers removed, run a water test and confirm the head turns smoothly and every nozzle has even flow.

The pump cuts in and out. Is it the pump? Check its connector and cable first. A fault that changes with movement is usually wiring.

Will a P100 Pro pump fit? Do not assume so. Match the XAG part number; this one is identified for the original P100.

Can I run the pump dry to check it? Not recommended. Running dry heats the tube and loads the drive.

Should I flush the system when fitting it? Yes. Flush with clean water so the new pump starts clean.

How can I make the pump last? Never run it dry and replace the tube before it splits.

Should I keep spares? Keep tube kits on hand; a spare pump suits fleets running high hours.

How do I confirm the part number? Look for XAG part number 05-002-01383 and the Type A designation on the packaging, or send us what you found and we will confirm the match.

View full details

Contact form