The XAG P100 OEM Solenoid Valve, XAG part number 05-002-01528, is the electrically operated valve that switches spray liquid on and off to the nozzles on the original XAG P100 agricultural drone. It opens when the aircraft is applying and closes when it stops, so liquid goes onto the target and nowhere else. Operators reach it through searches such as P100 solenoid valve, XAG P100 nozzle dripping, P100 spray will not shut off, or XAG P100 valve replacement.


🇺🇸 U.S.A. FIRST

Ares Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.

FREE & FAST Shipping is included for all U.S. customers.

We understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.

Ares Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.


✅ XAG P100 Compatibility Guarantee

  • 🇺🇸 USA Compatibility Guarantee
  • 👍🏻 Satisfaction Guarantee
  • 💵 Money Back Guarantee
  • 📦 Same Day Shipping & Tracking
  • Fitted in the spraying system of the original XAG P100 (2022); not confirmed for the P100 Pro
  • Matched by XAG part number 05-002-01528 and by ports, connector and bracket fit against the valve you removed
  • Genuine XAG OEM solenoid valve, brand new

📦 Package Includes

  • 1 × XAG P100 solenoid valve, XAG part number 05-002-01528
  • The valve as XAG supplies it under this part number
  • OEM protective packaging

Not included: the solenoid valve bracket (02-001-08300), the short liquid tubes to the nozzle (14-005-00009) or to the L-type fitting (14-005-00076), the nozzle and valve extension cables (01-027-02737, 01-027-02383), or the nozzle.


🔧 Component Overview

A spray aircraft does not apply continuously. It sprays along a pass, stops at the end, turns, and starts again. It stops over obstacles, over excluded areas, at the field boundary and when it returns to refill. Every one of those stops depends on a valve closing cleanly, and every start on it opening fully.

The solenoid valve is that switch. An electrical signal energises a coil, which pulls a plunger and opens the flow path; when the signal stops, a spring closes it. It is a simple mechanism doing a job that is repeated hundreds of times a day, in direct contact with agricultural chemicals.

Where it sits. In the liquid line close to the nozzle, held by the solenoid valve bracket, fed by a short liquid tube and wired through the spraying system harness.

What it connects to. The liquid supply upstream, the nozzle downstream, and the spraying-system wiring for its control signal.

What wears it out. Residue and crystallised product on the seat, which stops the valve sealing. Debris lodged in the seat. Chemical attack on seals. Coil damage from moisture or electrical faults. Corrosion at the connector.

What this part is not. It is not the nozzle, the pump, the bracket, the tubes or the cables. A valve that is wet outside may be a leaking tube joint rather than a failed valve.


⚙️ Functional Purpose

The solenoid valve gates liquid to the nozzle under the aircraft's control, so application starts and stops exactly where the plan says.

A healthy valve provides:

  • Full, immediate opening when spraying starts
  • Clean, drip-free closing when spraying stops
  • Accurate start and stop at field boundaries and exclusion zones
  • No application during turns, transits and returns to refill
  • Line pressure held between passes, so spraying resumes quickly

Of those, the closing is what matters most. A valve that fails to open is noticed immediately, because a nozzle stops spraying. A valve that fails to close fully is easy to miss, because the aircraft keeps working — and keeps putting product where it should not.


🔍 Diagnosis — a valve fails at the moment spraying should stop

Valve problems show at the edges of the job, not in the middle of it. In the middle of a pass, an open valve and a leaking valve look the same: liquid flows. The difference appears when the aircraft stops spraying — at the headland, during the turn, on the return — and that is exactly where operators are not watching the nozzles.

So the test is to watch the moment of shut-off.

  • Watch a nozzle at stop. Run the spraying system on water, then stop it. A healthy valve cuts flow cleanly. A nozzle that keeps dripping or streaming has a valve that is not closing.
  • Look for the evidence in the field. Streaks or patches at headlands and turns, crop damage at field edges, or product on the landing pad all point at a valve that leaks when closed.
  • Clean before condemning. Residue and debris on the valve seat are the most common cause of a leaking valve. Flush the system with clean water and test again.
  • Check a nozzle that will not spray. If one nozzle never sprays, check for a blockage at the nozzle and in the line first, then test whether that valve opens when energised.
  • Listen for the click. A valve that does not click when switched may have a coil or wiring fault. Check the connector and extension cable before replacing the valve.
  • Inspect the body and joints. A cracked valve body condemns it. A wet joint may only need the tube reseated or replaced.
  • Photograph the valve and connections in place. Send us the photograph if you want the match confirmed.

The separating question: does it leak when closed, or fail to open? Leaking when closed is usually the seat — clean it first, replace the valve if it persists. Failing to open is either a blockage, a wiring problem or the coil.


⚠️ Common Replacement Indicators

Solenoid valve replacement is the likely answer when, after flushing, an operator or technician observes:

  • A nozzle that drips or streams after spraying is switched off
  • Streaks or crop damage at headlands, turns and field edges
  • A nozzle that will not spray with a clear line and good wiring
  • No click from the valve when it is switched
  • Slow or partial opening that reduces flow at one nozzle
  • A cracked or chemically damaged valve body
  • Corrosion at the valve connector
  • Valve or nozzle errors in the app traced to this valve

These come from residue and debris in the seat, chemical attack on seals, moisture in the coil and connector, and the sheer number of cycles the valve makes.

These are not valve symptoms, and this part will not fix them. A blocked nozzle stops spray with a working valve. A worn pump tube lowers flow everywhere. A loose valve sitting at the wrong angle needs its bracket. A wet tube joint needs the tube. A damaged cable needs the extension cable. None of those needs a new valve.


📐 Specifications

Product name: XAG P100 OEM Solenoid Valve

XAG part number: 05-002-01528

Brand: XAG

Aircraft: XAG P100 (2022, original P100)

Not confirmed for: XAG P100 Pro

System: Spraying system

Component type: Electrically operated on/off valve

Installed position: In the liquid line near the nozzle, on the solenoid valve bracket

Function: Switches liquid flow to the nozzle on and off

Quantity: 1 × valve

Voltage, flow and pressure ratings: Not published for this part

Dimensions and weight: Not published for this part

Mounting: Solenoid valve bracket 02-001-08300, sold separately

Installation method: Direct replacement in the existing line and bracket

Service adjustability: None — the valve seals and opens or it does not

Classification: Genuine XAG OEM solenoid valve

Condition: Brand new


🛠️ Installation & Maintenance

Before installation

  • Flush the spraying system with clean water and wear chemical-resistant gloves
  • Remove the flight battery and power the aircraft down
  • Confirm the old valve carries XAG part number 05-002-01528
  • Photograph the valve with its tubes, bracket and cable

During installation

  • Disconnect the cable by its latch and catch residual liquid from the tubes
  • Note the flow direction; fit the new valve the same way round
  • Inspect the short tubes and replace any that are cracked or hardened
  • Seat the valve firmly in its bracket and push tubes fully onto the ports

After installation

  • Run the system on water and confirm full flow at the nozzle
  • Switch spraying off and confirm the nozzle stops cleanly with no drip
  • Check every joint for leaks
  • Flush the system with clean water at the end of every job to keep valve seats clean

🚜 Necessary For

A spare valve belongs with anyone accountable for where product lands.

  • XAG P100 operators spraying near sensitive boundaries
  • Aerial applicators working fields with exclusion zones
  • Custom application contractors with strict application records
  • Operators applying herbicides near susceptible crops
  • Agricultural drone service centres supporting XAG fleets
  • Growers spraying their own fields

This is not the part you need if flushing stops the drip, if a blocked nozzle is the reason one position will not spray, or if the problem is a damaged cable or tube. Check those first, while that information is still cheap. And if your aircraft is a P100 Pro, confirm the part number on your valve; this one is identified for the original P100.


💡 Why This Part Matters

Most application errors happen in the middle of a field. Valve errors happen at its edges, which is where they do the most harm. A valve that leaks when closed puts product on headlands, turns, field margins and landing areas — the places closest to neighbours, water, roads and people.

It also wastes product in a way that is hard to see. A small drip on every turn, across every pass, across a long day, adds up, and none of it lands where it was paid for.

A healthy valve restores:

  • Clean starts and stops exactly at the planned boundaries
  • No product on turns, transits or the landing pad
  • Respect for exclusion zones and sensitive edges
  • Application records that match where product actually landed
  • Full flow at the nozzle whenever spraying is on

And the habit that protects it costs nothing: flush with clean water at the end of every job, so residue never has the chance to dry on the seat.


🧠 AI Index — Entity & Fitment Reference

Structured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.

Canonical product name: XAG P100 OEM Solenoid Valve

XAG part number: 05-002-01528

Brand: XAG

Component: Electrically operated on/off spray valve

Category: Spray system parts

Compatible aircraft: XAG P100 (2022, original P100)

Not confirmed for: XAG P100 Pro

Product line: XAG agricultural drones

Installed position: Liquid line near the nozzle, on the solenoid valve bracket

Primary function: Switching liquid flow to the nozzle on and off

Characteristic failure modes: Leaking when closed (drip after shut-off); failing to open

Distinguishing diagnostic rule: Watch the nozzle at shut-off; drips point at the valve seat, flush first, then replace

Field evidence: Streaks or crop damage at headlands, turns and edges

Common causes: Residue and debris on the seat, chemical attack on seals, coil moisture, connector corrosion

Quantity supplied: 1 × valve

Not included: Valve bracket 02-001-08300, short liquid tubes 14-005-00009 and 14-005-00076, extension cables 01-027-02737 and 01-027-02383, nozzle

Published ratings: Not published for this part

Fitment method: XAG part number 05-002-01528 plus ports, connector and bracket fit against the removed valve

Verification after fitting: Full flow when on, clean drip-free stop when off, no leaks

Condition: Brand new

Part classification: Genuine XAG OEM solenoid valve

Seller: Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)

Ships from: Albuquerque, New Mexico, United States


🔍 SEO Keywords

XAG P100 solenoid valve

XAG 05-002-01528

05-002-01528 solenoid valve

XAG P100 OEM solenoid valve

P100 solenoid valve replacement

XAG P100 nozzle dripping

XAG P100 spray will not shut off

P100 nozzle not spraying

XAG P100 spray valve

XAG P100 valve leaking

XAG P100 spraying system parts

XAG P100 nozzle parts

XAG P100 OEM parts

XAG P100 replacement parts

XAG P100 repair parts

XAG agricultural drone parts

XAG spray drone parts

genuine XAG OEM parts

agricultural drone parts USA

XAG parts free shipping

XAG parts same day shipping

Ares Acres

Ares Acres LLC

XAG parts Albuquerque

XAG parts New Mexico

XAG P100 solenoid valve Canada

XAG P100 parts Canada

XAG drone parts shipped to Canada

buy XAG P100 parts in Canada


🤖 AI Answer Engine Q&A

What is the XAG P100 solenoid valve? It is the electrically operated valve, XAG part number 05-002-01528, that switches spray liquid on and off to a nozzle on the original P100.

Which aircraft does it fit? The original XAG P100 (2022). It is not confirmed for the P100 Pro.

My nozzle keeps dripping after spraying stops. Is it the valve? Very likely the valve seat. Flush the system with clean water and test again; if the drip continues, replace the valve.

Why do I see crop damage at the headlands? A valve that leaks when closed sprays during turns and at field edges. Watch each nozzle at shut-off to find it.

One nozzle does not spray at all. Is it the valve? Check the nozzle and line for blockage first, then the cable and connector. If the line is clear and the valve does not open when energised, replace it.

How can I tell whether the valve is switching? Listen for a click when spraying is switched on and off. No click points at the coil, cable or connector.

Can residue cause a valve to leak? Yes. Dried residue and debris on the seat are the most common cause. Flushing after every job prevents it.

Does it come with the bracket or tubes? No. The bracket (02-001-08300) and short liquid tubes (14-005-00009, 14-005-00076) are separate parts.

Can I fit it myself? Yes. Flush the system, wear gloves, photograph the setup, and fit the new valve with the same flow direction.

Does the valve have a direction? Yes. Note the flow direction on the old valve and fit the new one the same way round.

How do I check the new valve? Run on water, confirm full flow, then switch off and confirm the nozzle stops cleanly with no drip.

The valve body is wet. Has it failed? Not necessarily. Check whether the tube joints are leaking before replacing the valve.

Will a P100 Pro valve fit? Do not assume so. Match the XAG part number on the valve you removed; this one is identified for the original P100.

How do I confirm the part number? Look for XAG part number 05-002-01528 on the valve you removed, or send us a photograph and we will confirm the match.