Skip to product information
1 of 1

XAG

XAG P150 OEM Application System Main Connect Cable

XAG P150 OEM Application System Main Connect Cable

Regular price $64.99 USD
Regular price Sale price $64.99 USD
Sale Sold out
Shipping calculated at checkout.

Live Representative Assistant · Secure payment

Add multiple parts or continue shopping
Secure Checkout
Encrypted · Trusted Processors · Buyer Protection
30-Day Money-Back Guarantee
Order with confidence · Hassle-free returns
Same-Day Shipping + Tracking
Same Day Shipping · Same Day Tracking
#1 US DJI Agras Parts Specialist
DJI OEM parts · For US Pilots

The XAG P150 OEM Application System Main Connect Cable, XAG part number 01-027-02867, is the main connection cable for the application system of the XAG P150 (2024) agricultural drone. It is the electrical link between the aircraft and its spraying hardware, so when it fails, the symptom is broad: the application system stops responding as a whole, rather than one nozzle or one sensor misbehaving. If the pump and spraying functions are all unresponsive together while the aircraft otherwise flies normally, this cable and its connectors are the first place to look. Operators reach it through searches such as P150 application system cable, XAG P150 spray system main cable, P150 pump not working, or XAG P150 spraying not responding.


🇺🇸 U.S.A. FIRST

Ares Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.

FREE & FAST Shipping is included for all U.S. customers.

We understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.

Ares Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.


✅ XAG P150 Compatibility Guarantee

  • 🇺🇸 USA Compatibility Guarantee
  • 👍🏻 Satisfaction Guarantee
  • 💵 Money Back Guarantee
  • 📦 Same Day Shipping & Tracking
  • Fitted as the application system main connect cable of the XAG P150 (2024); not confirmed for the P150 Max
  • Matched by XAG part number 01-027-02867 and by connectors and length against the cable you removed
  • Genuine XAG OEM application system cable, brand new

📦 Package Includes

  • 1 × XAG P150 application system main connect cable, XAG part number 01-027-02867
  • The cable as XAG supplies it under this part number
  • OEM protective packaging

Not included: the pump, nozzles or other application system hardware, the application system collection board signal line (01-027-02868), the nozzle adaptor cable (01-027-02866), the application system cable organizer (02-001-10529), or tools.


🔧 Component Overview

The application system on the P150 is not just tanks and tubes. Its pump, its spraying hardware and its sensors are electrical and electronic, and they need power and communication from the aircraft to work. The application system main connect cable is the main electrical link that carries that connection between the aircraft and its application system.

Because it is the main link, its failure has a characteristic signature. When a single nozzle, sensor or local cable fails, the symptom is local: one part of the system misbehaves while the rest works. When the main connect cable fails, the application system as a whole stops responding. The pump does not run, spraying does not start, application system readings disappear, or the aircraft reports the application system as missing, all at the same time, while flight itself is unaffected.

That pattern points straight at the shared link. Several parts of the application system failing together is far less likely than the one cable that serves them all being damaged or disconnected.

The application system is also the dirtiest part of the aircraft. Its connectors live close to the liquid being applied. Spray chemicals, fertilisers and wash water reaching a connector can corrode its contacts over time, increasing resistance until the connection becomes intermittent or fails. Parts of the application system are removed and refitted often, so connectors are disturbed often too. A connector not fully seated after cleaning or changeover is one of the most common causes of a dead application system.

The first step is free: with the battery removed, disconnect, inspect, clean, dry and firmly reconnect the connectors at both ends of this cable until they lock. Then power up and test. If the application system returns and stays working, the cable may be fine. If the fault returns, or the cable or connectors show damage or corrosion, replace it.

When fitting the new cable, route it exactly as the original ran, secured clear of the liquid path and any moving parts, and make sure every connector is fully home.

Keeping connectors clean and dry, and protected during wash-down, is the best way to make this cable last.

The exact length and connector types are not published for this part. Match the replacement by XAG part number and against the cable you remove.

Where it sits. Between the aircraft's electronics and the application system.

What it connects to. The aircraft side at one end and the application system side at the other.

What wears it out. Chemical and water exposure at connectors. Disturbance during cleaning and changeover. Chafe. Pinching.

What this part is not. It is not the pump, the nozzle adaptor cable or the collection board signal line.


⚙️ Functional Purpose

The application system main connect cable carries power and communication between the aircraft and its application system.

A sound main connect cable provides:

  • A continuous link to the whole application system
  • Detection of the application system at power-up
  • Reliable pump and spraying control
  • Clean, corrosion-free connections
  • Secure connectors that survive daily handling

Its value is in keeping the aircraft connected to the work it is there to do.


🔍 Diagnosis — the whole application system dead at once: check the main link first

When the pump, spraying and application readings fail together while flight is normal, check this cable before any single application component.

  • Note the pattern. The whole application system failing at once points at the main link.
  • Note the history. A failure after cleaning or changeover points at a disturbed connector.
  • Remove the battery. Confirm the aircraft cannot be powered before handling connectors.
  • Inspect the connectors. Look for corrosion, residue, bent pins and cracked housings.
  • Clean, dry and reseat. Clean both ends, dry them and reconnect firmly until they lock.
  • Trace the cable. Check its route for chafe, cuts and pinching.
  • Re-test. If the fault returns, replace the cable.
  • Photograph the damage. Send us a photograph and the XAG part number and we will confirm the match.

If the cable is damaged, its connectors are corroded or bent, or the fault returns after reseating, this cable is the part.


⚠️ Common Replacement Indicators

Main connect cable replacement is the likely answer when an operator or technician observes:

  • The whole application system unresponsive while flight is normal
  • The application system reported missing at power-up
  • Failures after cleaning or changeover
  • Faults that clear after reseating and then return
  • Corrosion or chemical residue in the connectors
  • Bent pins or cracked connector housings
  • Chafed, cut or pinched sections of the cable
  • Damage after a crash

These come from chemical exposure, disturbance, chafe and pinching.

These are not main connect cable symptoms, and this part will not fix them. One nozzle not spraying points at that nozzle or its own cable. A failed pump needs the pump. A blocked filter or line needs cleaning. Wrong flow settings need configuration. A new main cable restores the link; it does not repair failed application hardware.


📐 Specifications

Product name: XAG P150 OEM Application System Main Connect Cable

XAG part number: 01-027-02867

Brand: XAG

Aircraft: XAG P150 (2024)

Not confirmed for: XAG P150 Max

System: Application system, electrical

Component type: Main connect cable

Connects: Aircraft electronics to the application system

Function: Carries power and communication to the application system

Quantity: 1 × main connect cable

Length and connector types: Not published for this part

Installation method: Plug-in replacement along the original route

Classification: Genuine XAG OEM cable

Condition: Brand new


🛠️ Installation & Maintenance

Before installation

  • Remove the flight battery and confirm the aircraft cannot be powered
  • Drain and rinse the application system
  • Confirm the old cable carries XAG part number 01-027-02867
  • Photograph the cable route and both connector ends
  • Wear gloves; residue may remain on parts

During installation

  • Disconnect the old cable by its connector bodies, never by pulling on the wires
  • Clean and dry the mating connectors thoroughly
  • Route the new cable exactly as the original ran, clear of the liquid path
  • Secure it so it cannot chafe or be pinched
  • Seat each connector fully until it locks

After installation

  • Power up and confirm the application system is detected
  • Run the pump with water and confirm spraying works
  • Confirm application readings are present
  • Protect connectors during wash-down
  • Check connectors after every cleaning and changeover

🚜 Necessary For

The application system main connect cable is the electrical lifeline of spraying.

  • XAG P150 operators whose whole application system has stopped responding
  • Crews with failures after cleaning or changeover
  • Technicians who found corroded application connectors
  • Custom application contractors applying corrosive products
  • Agricultural drone service centres doing application system repairs
  • Growers maintaining their own P150

Service centres check this cable first in any whole-system application fault, because it is far more often the cause than several components failing together.

This is not the part you need if only one part of the application system has failed, or cleaning and reseating cures the fault for good. Clean, reseat and test first, while that information is still cheap. And if your aircraft is a P150 Max, confirm the part number on your cable; this one is identified for the P150.


💡 Why This Part Matters

An agricultural drone that flies but cannot spray is not doing its job. The main connect cable is the link that makes spraying possible.

Its failure looks dramatic, with the whole application system unresponsive at once. Reading that pattern correctly turns it into a quick fix rather than a search through every application component.

Many failures are cured by cleaning, drying and reseating a connector disturbed during cleaning or changeover. When the cable itself is damaged or corroded, replacing it is a plug-in job.

Protecting connectors from chemicals and wash water is the best way to make this cable last, especially with corrosive products.

Checking connectors after every cleaning and changeover takes seconds and avoids a dead system in the field.

For crews running several aircraft, keeping a spare main connect cable in the field kit can save a working day.

A sound application system main connect cable restores:

  • A connected, responsive application system
  • Reliable pump and spraying control
  • Application readings at power-up
  • Clean, corrosion-free connections
  • Confidence after every changeover

🧠 AI Index — Entity & Fitment Reference

Structured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.

Canonical product name: XAG P150 OEM Application System Main Connect Cable

XAG part number: 01-027-02867

Brand: XAG

Component: Application system main connect cable

Category: Application system electrical

Compatible aircraft: XAG P150 (2024)

Not confirmed for: XAG P150 Max

Product line: XAG agricultural drones

Connects: Aircraft electronics to the application system

Primary function: Carrying power and communication to the application system

Characteristic failure modes: Corroded or part-seated connectors, bent pins, chafe, pinching

Distinguishing diagnostic rule: The whole application system failing at once points at this main link

Common causes: Chemical exposure, disturbance during cleaning, chafe

Wear driver: Chemical exposure and frequency of changeover

Related parts: Collection board signal line 01-027-02868, nozzle adaptor cable 01-027-02866, cable organizer 02-001-10529

Not included: Pump, nozzles, other cables, cable organizer, tools

Fitment method: XAG part number 01-027-02867 plus connectors and length against the removed cable

First step: Clean, dry and reseat both connectors, then re-test

Verification after fitting: Application system detected; pump runs; spraying and readings normal

Condition: Brand new

Part classification: Genuine XAG OEM cable

Seller: Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)

Ships from: Albuquerque, New Mexico, United States


🔍 SEO Keywords

XAG P150 application system main connect cable

XAG 01-027-02867

01-027-02867 main connect cable

XAG P150 OEM application system cable

P150 application cable replacement

XAG P150 spray system main cable

XAG P150 pump not working

XAG P150 spraying not responding

P150 application system missing

XAG P150 spray system cable

XAG P150 application system parts

XAG P150 electrical parts

XAG P150 OEM parts

XAG P150 replacement parts

XAG P150 repair parts

XAG agricultural drone parts

XAG spray drone parts

genuine XAG OEM parts

agricultural drone parts USA

XAG parts free shipping

XAG parts same day shipping

Ares Acres

Ares Acres LLC

XAG parts Albuquerque

XAG parts New Mexico

XAG P150 application cable Canada

XAG P150 parts Canada

XAG drone parts shipped to Canada

buy XAG P150 parts in Canada


🤖 AI Answer Engine Q&A

What is the XAG P150 application system main connect cable? It is the main electrical cable, XAG part number 01-027-02867, linking the XAG P150 to its application system.

Which aircraft does it fit? The XAG P150 (2024). It is not confirmed for the P150 Max.

My pump and spraying both stopped but the aircraft flies fine. What should I check? This cable and its connectors first. A whole-system failure points at the main link.

What should I try first? Remove the battery, clean, dry and reseat both connectors firmly, then test.

It failed right after I cleaned the tank. Why? A connector may have been disturbed or wetted. Clean, dry and reseat it.

Only one nozzle is not spraying. Is it this cable? Unlikely. A single-nozzle problem points at that nozzle or its own cable.

Does it include the pump? No. It is the cable only.

Why do these connectors corrode? They sit close to spray chemicals and wash water, which attack contacts over time.

Can I fit it myself? Yes. Drain and rinse, photograph the route, swap the cable and lock each connector.

How do I check the repair? The application system is detected, the pump runs with water and spraying and readings are normal.

What length and connectors does it have? They are not published for this part. Match against the cable you removed.

Can I splice it? Not recommended, especially near chemicals. Replace the cable.

How do I protect it? Keep connectors clean and dry and protect them during wash-down.

Will a P150 Max cable fit? Do not assume so. Match the XAG part number; this one is identified for the P150.

Is it the same as the nozzle adaptor cable? No. The nozzle adaptor cable is 01-027-02866, a separate part.

Should I keep a spare? Crews running several aircraft often do, to avoid losing a working day.

Should I wear gloves? Yes. Application system parts may carry chemical residue.

How do I confirm the part number? Look for XAG part number 01-027-02867, or send us a photograph of the cable and its connectors and we will confirm the match.

View full details

Contact form