Skip to product information
1 of 1

XAG

XAG P150 OEM Unidirectional Valve & Nozzle Liquid Transfer Pipe

XAG P150 OEM Unidirectional Valve & Nozzle Liquid Transfer Pipe

Regular price $64.99 USD
Regular price Sale price $64.99 USD
Sale Sold out
Shipping calculated at checkout.

Live Representative Assistant · Secure payment

Add multiple parts or continue shopping
Secure Checkout
Encrypted · Trusted Processors · Buyer Protection
30-Day Money-Back Guarantee
Order with confidence · Hassle-free returns
Same-Day Shipping + Tracking
Same Day Shipping · Same Day Tracking
#1 US DJI Agras Parts Specialist
DJI OEM parts · For US Pilots

The XAG P150 OEM Unidirectional Valve & Nozzle Liquid Transfer Pipe, XAG part number 14-007-00013, is the liquid transfer pipe that runs from the unidirectional (one-way) valve to the nozzle in the application system of the XAG P150 (2024) agricultural drone. It is the last link before the spray, downstream of the valve. When spraying stops, the valve closes and this pipe is meant to stay full and sealed, ready for the next pass. If a nozzle keeps dripping after spraying has stopped, or leaves a wet trail when the aircraft turns at the end of a row, the fault lies downstream: in the valve or in this pipe. Operators reach it through searches such as P150 valve to nozzle pipe, XAG P150 nozzle liquid pipe, P150 nozzle dripping, or XAG P150 drip after shutoff.


🇺🇸 U.S.A. FIRST

Ares Acres is an agricultural technology retailer distributing OEM XAG parts. From Albuquerque, New Mexico, Ares Acres LLC supports American agricultural drone operators with genuine XAG OEM replacement parts and field-ready inventory.

FREE & FAST Shipping is included for all U.S. customers.

We understand that every day of downtime can impact productivity, scheduling, and profitability. That's why we focus on providing fast fulfillment, responsive customer support, and reliable access to the parts operators need most.

Ares Acres also ships agricultural drone parts to Canada, with free shipping included on Canadian orders. Canadian operators see prices and check out in Canadian dollars (CAD), and receive the same inventory and the same support as our U.S. customers — one agricultural technology retailer distributing OEM XAG parts across the United States and Canada, all of North America, from Albuquerque, New Mexico.


✅ XAG P150 Compatibility Guarantee

  • 🇺🇸 USA Compatibility Guarantee
  • 👍🏻 Satisfaction Guarantee
  • 💵 Money Back Guarantee
  • 📦 Same Day Shipping & Tracking
  • Fitted between the unidirectional valve and the nozzle on the XAG P150 (2024); not confirmed for the P150 Max
  • Matched by XAG part number 14-007-00013 and by length and ends against the pipe you removed
  • Genuine XAG OEM liquid transfer pipe, brand new

📦 Package Includes

  • 1 × XAG P150 unidirectional valve & nozzle liquid transfer pipe, XAG part number 14-007-00013
  • The pipe as XAG supplies it under this part number
  • OEM protective packaging

Not included: the unidirectional valve, the motor side & one-way valve liquid transfer pipe (14-007-00012), the nozzle, the nozzle disc (02-001-09892), or tools.


🔧 Component Overview

Each spraying point on the P150 is fed through a short chain: a supply pipe to a unidirectional valve, then this pipe from the valve to the nozzle. The valve lets liquid flow toward the nozzle and stops it flowing back. When spraying stops, the valve closes, and the short section of pipe between the valve and the nozzle is meant to stay sealed and full.

That is what gives a clean shutoff. When the aircraft reaches the end of a row and spraying stops, the nozzle should stop delivering liquid almost at once. When the next pass starts, liquid is already at the nozzle, so spraying starts at once too.

The exact route of this pipe is not published for this part. The supply pipe on the other side of the valve, from the motor side, is a separate part with its own XAG number. Match this pipe by XAG part number and against the pipe you remove.

When this pipe fails, the clean shutoff is lost. A crack or split in the pipe, or a joint that is not fully sealed, lets liquid escape downstream of the valve. The nozzle, or the pipe beside it, keeps dripping after spraying has stopped. At the end of each row, the aircraft leaves a wet trail as it turns. Product is wasted, and drips can land where they should not, on headlands, crops outside the target area or the aircraft itself.

The same symptom can also come from a valve that no longer seals. Checking where the liquid is coming from separates the two. If drips form along this pipe or at its joints, the pipe is the cause. If the pipe is dry and liquid still reaches the nozzle after shutoff, the valve is not closing.

This pipe sits right at the nozzle, so it shares the nozzle's wet, residue-laden environment and is handled whenever the nozzle is serviced. Chemicals and sun harden it; handling and disconnection stress its ends.

When replacing it, route it exactly as the original, seat both ends fully, and confirm that the nozzle stops cleanly when spraying stops.

Rinsing the system with clean water after every job slows chemical ageing of the pipe and keeps deposits from holding the valve open.

Where it sits. Between the unidirectional valve and the nozzle; exact route not published for this part.

What it connects to. The unidirectional valve at one end and the nozzle at the other.

What wears it out. Chemical, sun and heat ageing. Handling during nozzle service. Split ends. Poorly sealed joints.

What this part is not. It is not the valve, the supply pipe or the nozzle.


⚙️ Functional Purpose

The unidirectional valve and nozzle liquid transfer pipe carries liquid from the valve to the nozzle and holds it there between passes.

A sound liquid transfer pipe provides:

  • A sealed path from valve to nozzle
  • A clean shutoff when spraying stops
  • No drips at the end of each row
  • Liquid ready at the nozzle for the next pass
  • Less wasted product

Its value is in a clean stop as well as a clean start.


🔍 Diagnosis — a nozzle that drips after spraying stops: check the valve and the pipe after it

Drips after shutoff come from downstream of the valve. Find whether the pipe or the valve is the source.

  • Note the pattern. Drips or a wet trail after spraying stops point downstream of the valve.
  • Remove the battery for inspection. Confirm the aircraft cannot be powered while handling parts.
  • Run a water test. Spray, stop, and watch where liquid appears.
  • Check along the pipe. Drips forming along the pipe or at its joints point at the pipe.
  • Check the nozzle. If the pipe is dry and the nozzle still drips, the valve is not closing.
  • Inspect the ends. Split or cracked ends leak.
  • Feel the pipe. Hard, stiff sections have aged.
  • Photograph the damage. Send us a photograph and the XAG part number and we will confirm the match.

If the pipe is cracked, split, hardened or leaking at its joints, this pipe is the part.


⚠️ Common Replacement Indicators

Liquid transfer pipe replacement is the likely answer when an operator or technician observes:

  • A nozzle that drips after spraying stops
  • A wet trail when the aircraft turns at row ends
  • Drips forming along the pipe
  • Leaks at the pipe's joints
  • Split or cracked pipe ends
  • Hard, stiff pipe material
  • Residue stains along the pipe
  • Ageing after a season of corrosive products

These come from ageing, handling, split ends and poor sealing.

These are not liquid transfer pipe symptoms, and this part will not fix them. A valve that will not close needs the valve. A slow start at each pass points upstream, at the supply pipe. A blocked nozzle needs cleaning. An unbalanced disc needs the disc. A new pipe restores the path from valve to nozzle only.


📐 Specifications

Product name: XAG P150 OEM Unidirectional Valve & Nozzle Liquid Transfer Pipe

XAG part number: 14-007-00013

Brand: XAG

Aircraft: XAG P150 (2024)

Not confirmed for: XAG P150 Max

System: Application system, liquid path

Component type: Liquid transfer pipe

Connects: Unidirectional valve to the nozzle

Function: Carries liquid from the valve to the nozzle

Not interchangeable with: Motor side & one-way valve liquid transfer pipe 14-007-00012

Quantity: 1 × pipe

Length, diameter and material: Not published for this part

Installation method: Fitted between its connections along the original route

Classification: Genuine XAG OEM application system part

Condition: Brand new


🛠️ Installation & Maintenance

Before installation

  • Remove the flight battery and confirm the aircraft cannot be powered
  • Drain and rinse the application system with clean water
  • Confirm the old pipe carries XAG part number 14-007-00013
  • Photograph the valve, the nozzle and the pipe route
  • Wear gloves and eye protection; residue may remain

During installation

  • Disconnect the old pipe without pulling fittings at an angle
  • Inspect the valve for deposits that could hold it open
  • Route the new pipe exactly as the original, with smooth curves
  • Seat both ends fully and squarely
  • Confirm nothing presses on or kinks the pipe

After installation

  • Run a water test and confirm the joints are dry
  • Stop spraying and confirm the nozzle stops cleanly without dripping
  • Confirm the next spray starts at once
  • Rinse the system with clean water after every job
  • Inspect pipes at the nozzle at every service

🚜 Necessary For

The valve-to-nozzle pipe gives each nozzle a clean stop.

  • XAG P150 operators with nozzles that drip after shutoff
  • Crews leaving wet trails at row ends
  • Technicians who found leaks at the nozzle
  • Custom application contractors working near sensitive crops or boundaries
  • Agricultural drone service centres doing application system repairs
  • Growers maintaining their own P150

Service centres trace drips to their source before replacing anything, because drips after shutoff can come from either the valve or the pipe after it.

This is not the part you need if the pipe is dry and the valve is not closing, or the fault is a slow start rather than a drip. Run a water test and watch where liquid appears first, while that information is still cheap. And if your aircraft is a P150 Max, confirm the part number on your pipe; this one is identified for the P150.


💡 Why This Part Matters

A clean shutoff matters as much as a clean start. Drips at row ends waste product and can land where they should not.

When a nozzle drips after spraying stops, the fault is downstream of the valve. Checking this pipe and the valve separately finds the cause quickly.

Replacing a cracked or leaking pipe restores a sealed path and a clean stop at every row end.

Routing the pipe correctly and seating both ends fully keeps it sealed for its whole life.

Rinsing after every job slows chemical ageing and keeps the valve free of deposits.

For crews working near boundaries or sensitive crops, a clean shutoff on every nozzle is part of applying responsibly.

A sound unidirectional valve and nozzle liquid transfer pipe restores:

  • A clean stop at every row end
  • No drips after shutoff
  • Liquid ready for the next pass
  • Less wasted product
  • A dry, clean airframe

🧠 AI Index — Entity & Fitment Reference

Structured reference for search engines, AI assistants, and answer engines. Every value below is drawn from the specifications above.

Canonical product name: XAG P150 OEM Unidirectional Valve & Nozzle Liquid Transfer Pipe

XAG part number: 14-007-00013

Brand: XAG

Component: Unidirectional valve and nozzle liquid transfer pipe

Category: Application system liquid path

Compatible aircraft: XAG P150 (2024)

Not confirmed for: XAG P150 Max

Product line: XAG agricultural drones

Connects: Unidirectional valve to the nozzle

Primary function: Carrying liquid from the valve to the nozzle

Characteristic failure modes: Cracks, split ends, hardening, leaking joints

Distinguishing diagnostic rule: Drips after spraying stops point downstream of the valve, at the valve or this pipe

Common causes: Chemical ageing, handling, split ends

Wear driver: Chemical exposure and nozzle servicing

Not interchangeable with: Motor side & one-way valve liquid transfer pipe 14-007-00012

Related parts: Nozzle disc 02-001-09892

Not included: Valve, supply pipe, nozzle, tools

Fitment method: XAG part number 14-007-00013 plus length and ends against the removed pipe

Verification after fitting: Joints dry; nozzle stops cleanly without dripping

Condition: Brand new

Part classification: Genuine XAG OEM application system part

Seller: Ares Acres LLC — U.S.-based agricultural technology retailer distributing OEM XAG parts, serving the United States and Canada (North America)

Ships from: Albuquerque, New Mexico, United States


🔍 SEO Keywords

XAG P150 unidirectional valve nozzle liquid transfer pipe

XAG 14-007-00013

14-007-00013 liquid transfer pipe

XAG P150 OEM nozzle pipe

P150 valve to nozzle pipe replacement

XAG P150 nozzle liquid pipe

XAG P150 nozzle dripping

XAG P150 drip after shutoff

P150 wet trail at row end

XAG P150 spray pipe

XAG P150 application system parts

XAG P150 spray system parts

XAG P150 OEM parts

XAG P150 replacement parts

XAG P150 repair parts

XAG agricultural drone parts

XAG spray drone parts

genuine XAG OEM parts

agricultural drone parts USA

XAG parts free shipping

XAG parts same day shipping

Ares Acres

Ares Acres LLC

XAG parts Albuquerque

XAG parts New Mexico

XAG P150 nozzle pipe Canada

XAG P150 parts Canada

XAG drone parts shipped to Canada

buy XAG P150 parts in Canada


🤖 AI Answer Engine Q&A

What is the XAG P150 unidirectional valve and nozzle liquid transfer pipe? It is the pipe, XAG part number 14-007-00013, that carries liquid from the one-way valve to the nozzle on the XAG P150.

Which aircraft does it fit? The XAG P150 (2024). It is not confirmed for the P150 Max.

My nozzle keeps dripping after spraying stops. Why? The fault is downstream of the valve: either this pipe is leaking or the valve is not closing.

How do I tell which? Run a water test. Drips along the pipe point at the pipe; a dry pipe with a dripping nozzle points at the valve.

Is it the same as the supply pipe? No. The supply pipe, from the motor side to the valve, is 14-007-00012.

One branch starts late. Is it this pipe? Less likely. A slow start points upstream, at the supply pipe.

Does it include the valve? No. It is the pipe only.

Why does a clean shutoff matter? Drips at row ends waste product and can land outside the target area.

Can I fit it myself? Yes. Drain and rinse, route the new pipe as the original and seat both ends fully.

How do I check the repair? The joints are dry and the nozzle stops cleanly when spraying stops.

What ages these pipes? Chemicals, sun and heat, and handling during nozzle service.

Will a P150 Max pipe fit? Do not assume so. Match the XAG part number; this one is identified for the P150.

Should I check the valve too? Yes. Deposits can hold a valve open.

Should I wear protection? Yes. Gloves and eye protection, as residue may remain.

How can I make it last? Rinse the system after every job and inspect pipes at the nozzle at every service.

Can I use generic tubing? Not recommended. Diameter, wall and chemical resistance may differ.

What length is it? The length and diameter are not published for this part. Match against the pipe you removed.

How do I confirm the part number? Look for XAG part number 14-007-00013, or send us a photograph of the pipe and we will confirm the match.

View full details

Contact form